Ask Lasest Price | |
Brand Name : | FAMA/CHEVY LIGHT |
Certification : | CE(EN12368,LVD,EMC), GB14887-2011,IP55 |
Model Number : | FM10C-FN-44 |
Delivery Time : | 2-10days |
Payment Terms : | L/C,T/T,Western Union,Paypal |
Supply Ability : | 5200 Piece/Pieces per Day |
1.Product Function and Technical Feature:
Built-in central control system to ensure work stability; 2*48 work periods for workday and holiday setting;
Easy for maintenance and function extension by modular design;
Input AC110V and AC220V, Can be changed by the switch; Yellow flashing or close the signal can be setup at night;
Adopt RS-232 or LAN port to communicate with upper computer;
32 working menus used for any period(among 1~30 numbers customs can set it by themselves);
The flashing state, frequency and time of each green signal light can be setup or adjusted;
Can modify the current pace of running time in the running state immediately;
Full red, yellow flashing, step by step manual,jump in the manual,remote manual function(optional);
Be equipped with the hardware fault testing function(Red Light fails,Green lights up test),down grade to Yellow flash status and cut down the Red&Green light power supply when the fault happens.(Optional)
The output part adopts zero-test technology,Change of state is zero state switch in communication,Make the drive more safe and reliable;
Each output all the way with independent lightning protection circuit;
Installation testing capabilities,can test to confirm installation correctness for each lamp when installation at intersection;
The clients can set up 30 menu to be backup and recovery ;
The setup software can operation on the computer offline,Project data can be stored on the computer and can be copied.
2.Technical Parameters:
Items | Technical Parameters |
Executive Standard | GB25280-2010 |
Working Voltage | AC110V/220V±20% (changed by switch) |
Working Frequency | 47Hz~63Hz |
No-load power | ≤15W |
The whole controller rated load power | 2200W |
Motor operation sequence(special timing state should be statement before production) | all Red(can setup) →green light→green flash can setup) →yellow light→Red light |
Pedestrian signal operation sequence | all Red(can setup) →green light→Green flash(can setup)→Red light |
Rated drive current in each way | 3A |
surge current in each way | ≥100A |
The largest output channel independently | 44 |
The largest output way independently | 16 |
working menus | 32 |
Can be setup menus number | 30 |
The largest number of each meus | 24 |
The largest number of timers in each day | 48 |
Running time in each step | 1~255 |
Full red transition time | 0~5S |
Yellow light transition time | 1~9S |
Green flashing time | 0~9S |
OperationalTemperatureRange | -40℃~+80℃ |
Relative Humidity | <95% |
Setting Plan Saving Time(the electricity was turned off) | 10 years |
Time Error | Error/year<2.5 minutes (25±1℃) |
Inner Cabinet Dimension | 472.6*215.3*280mm |
Outer Cabinet Dimension | 1250*630*500mm |
3. Operation Panel button function introduction
4. Setup Instruction
4.1 Date Setting
Press Function button to make the date button is light,the digital tube will display the current date,press the Plus and Minus, the cursor will be moved to the digital which you want to modify. Press SAVE to save the plane after the completion of the modified,if press Exist, the exist the current setting cannot be saved.
Press Function, we will move to next stage-TimeSet:
4.2 Time Setting:
Press Function to time set,when the indicator light is lighting, the digital tube will display the current time(Hour,minute,second,day of the week),
Press the Plus and Minus to change the flashing digital,Press SAVE to save the plane after the completion of the modified,if press Exist, the exist the current setting cannot be saved.
Press Function can be moved to next set—Flash set/ Transition state parameter Settings:
4.3 Transition state parameter Settings
Press Function enters into the transition state parameter Settings,here we can be set up the green flashing time,the transition time of full red and yellow.,after the indicator lamp lights up,The digital tube will display the current flash time,press the Plus and Minus to modify the flashing time,Press SAVE to save the plane after the completion of the modified,if press Exist, the exist the current setting cannot be saved.
Press Function can be moved to next set—workday plan setting:
Note:we cab setupt the right simulation intersection to finish this stage.
direction stands for direction,Left and Right can be used to choose the light,Yes means ok, No means this light will be not setup this function:
4.4 Weekday scheme settings
Press Function button to enter the weekday scheme settings, The running time scheme can be setted from every Monday to Friday ! ( it can be setted up to 48 programs every day ), after the indicator lighten, The digits tube will display the current flashing time. We can modify the flashing digital through the Plus and Minus button, and press the left and right button can move the cursor to modify the digital. Note : we can’t modify the setting time at the first period time, when the time was setted to 24:00, that means the period time has been finished. After modification, , press the save button to save it. If you press the Exist button to exit current settings (non-preservation), Press the function key to enter the next state of holidays cheme settings.
4.5 Holidays scheme settings
Press the function button to enter the holidays scheme settings, the period time scheme can be setted from Saturday and Sunday ( you can set up to 48 period time at most) after the indicator lighten, The digits tube will display the current flashing time. We can modify the flashing digital through the Plus and Minus button, and press the left and right button can move the cursor to modify the digital. Note : we can’t modify the setting time at the first period time, when the time was setted to 24:00, that means the period time has been finished. After modification, , press the save button to save it. If you press the Exist button to exit current settings (non-preservation), Press the function key to enter the next state of holidays cheme settings.
of holidays cheme settings.
4.5 Setup Menu
Press the Funciton button to enter the menu program settings, the digits tube will be displays the digital presentation from left to right. Menu number ( we can set up to 30 sets programs at most). Step (setted up to 24 steps at most), and the current steps duration, when setting up this items, we can set up the green light for performed requirements as per the right side of simulated intersection, Direction, left and right are choose to the corresponding light, Yes means selected the light, By setting the current time step continuously, which can be setted the running time for traffic signal light, after finished that, press save key to enter the next step settings by automaticly, the same setting methods as above, and so on. When the steps time is set up to 0, press save key, and the current menu will be automatic end, then it will be back to the current operating state.
After changed the menu, we can modify the other menu, Pls kindly see the notes as below,
1, If the traffic signal light have conflict on release, such as green conflict /yellow flashing lights at this time, which can’t be saved, you need to choose the release traffic signal light again .
2, The total of menu number is 32 , you can set up it by yourself from 1-30, and the number of 31 is fixed yellow flashing time, the Number of 32 menu means the off menu, while the number 31 and number 32 menu can be exchanged between weekday scheme settings and holidays scheme settings.
The first step:
Press the left and right buttons to modify the digital as your needs, and press the plus and minus button to choose any digital what you want. Forexample, you can change the original setted time 9s to 8s or others. After setted as the picture ( the digital indicate the numbers), we can move on next setup
1. Enter to Number 01 menu settings.
2.To set Menu 02
5. Special Function Operations:
Introduction to the function of side-door switches and buttons
Remote controller operation introduction ( notes: it is as per
customers requirements to match)
1, The picture shows the remote controller as the right picture, the effective distance is about200m.
2, The left black parts is power supply for remote controller.
3, The Capitals of ABCD on the remote controller was corresponding function as below,
Capitals | A | B | C | D |
Function | Manually | Full red | Yellow flashing | Exit |
Six,The Common faults and solutions for controller
Item | Failure phenomena | Solutions scheme |
1 | The controller doesn’t work ,and has no power . | The fuse may be cut off. Users need to use a fuse of5Aor main fuse of10Ato change it. Main fuse is in the power socket. |
2 | The signal lights in the road intersection keep flashing amber and it is because of setting. | The reason maybe is the phasis setting, and there are have green conflicts ( the panel green conflict indicated light). You need to reset the phasis programs again. |
Seven,Packing List:
Item | Spare parts description | Quantity |
8. Signal Controller Wiring Diagram
Outputs port corresponding graph:
The digital returns the interface definition (notes: The same dedinition for 4pcs driver interface. )
Item | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
Description | Turn Left Red light | Left turn yellow light | Turn Left green light | Common Port | Go Straight Red light | Go straight Yellow light | Go straight green light |
8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |
Common port | Right turn Red light | Right turn yellow light | Right turn Green light | Common Port | Pedestrian red light | Pedestrian green light | Common Port |
9. The Whole Cabinet Wiring Diagram
Friendly Links: www.everychina.com
Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们