    K3166i Protective Relay Tester / Protection Relay Test Equipment 


    K3166i Universal Relay Test Set


    (All-in-one design,complying IEC61850 SV & GOOSE)

    Output Current: 6×35A@450VA max.


    3×70A@850VA max.


    Output Voltage: 7×310V@90VA max.


    Features


    All-in-One design, Integrated IEC61850 SV & GOOSE, 6I+7V analog channels output, Inbuilt GPS and IRIG-B, and other advance functions.


    1. Complied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc.


    2. 100/1000Mbit Fiber ports for SMV and GOOSE simulations.


    3. 6×35A & 7×310V independent high burden output channels.


    4. 13 channels independent low-level signal outputs.


    5. AC/DC measurement (8 channels inputs,class 0.1,0-600V/0-5A,auto range).


    6. Transducer calibartion (class 0.02).


    7. Energy meter calibration ( Mechanical & Electronic meters ).


    8. Analog and Binary Transient Record.


    9. Transient play back up to 3KHZ.


    10. Light weight <18kg


    11. Fully function KRT software testing modules.


    12. 3-Years guarantee of free repair and life-long maintenance.


    13. Free software upgrade.


    Ordering Ref.


    ModelCurrent OutputsVoltage Outputs
    K3166i6×35A@450VA max / 3×70A@850VA max7×310V@90VA max
    K3163i6×35A@450VA max / 3×70A@850VA max4×310V@124VA max
    K3130i3×35A@450VA max4×310V@124VA max
    K31666×35A@450VA max / 3×70A@850VA max7×130V@75VA max
    K31636×35A@450VA max / 3×70A@850VA max4×130V@75VA max
    K31303×35A@450VA max4×130V@75VA max

    Application


    Testing Items ANSI® No.


    IEC61850 numerical IEDs relay & merge unit --


    Distance protection relay 21


    Synchronising or synchronism-check relays 25


    Undervoltage relays 27


    Directional Power relays 32


    Undercurrent or underpower relays 37


    Negative sequence overcurrent relays 46


    Overcurrent/ground fault relays 50


    Inverse time overcurrent/ground fault relays 51


    Power factor relays 55


    Overvoltage relays 59


    Voltage or current balance relays 60


    Directional overcurrent relays 67


    Directional ground fault relays 67N


    DC overcurrent relays 76


    Phase-angle measuring or out-of-step protection relays 78


    Automatic reclosing devices 79


    Frequency relays 81


    Motor overload protection relays 86


    Differential protection relays 87


    Directional voltage relays 91


    Voltage and power directional relays 92


    Tripping relays 94


    Voltage regulating relays --


    Overimpedance relays, Z> --


    Underimpedance relays, Z --


    Time-delay relays --


    Characteristic


    1. 13 Channels (6×35A & 7×310V) outputs, each output channels are independent and simultaneous.


    2. Variable battery simulator, DC 0-350V, 140Watts max.


    3. 13 Low-level channels outputs up to 8Vac/10Vdc max.


    4. 0-600V / 0-5A AC/DC measurement in 0.1 class.


    5. Graphical test modules and templates for testing of various relays.


    6. Quick relay testing facility in Manual mode.


    7. Shot/Search/Check, Point & Click testing.


    8. RIO/XRIO import & export facility.


    9. Switch on to fault test(SOTF).


    10. Power system model for dynamic testing.


    11. Inbuilt GPS and IRIG-B sync end-to-end testing.


    12. Online Vector display.


    13. Automatic test results assume.


    14. Automatic test report creation.


    15. Anti-clipping detect,wrong wiring connect alarm and self-protect, overload and overheat protection.


    Parameter


    Voltage Outputs
    Output Range & Power7×310V ac (L-N)90VA max each
    3×620V ac (L-L)180VA max each
    3×350V dc (L-N)140W max each
    AccuracyAC:<0.03%Rd + 0.01Rg Typ. / <0.07%Rd + 0.03Rg Guar.
    DC: ±10mV @<5V,±0.5% @ ≥5V
    Resolution1mV
    Distortion<0.05% Typ. / <0.1% Guar.
    Current Outputs
    Output Range & Power6×35A ac(L-N)450VA max each
    3×70A ac(2L-N)850VA max each
    1×100A ac(6L-N)1200VA max
    3×20A dc(L-N)300W max each
    AccuracyAC:<0.05%Rd + 0.02Rg Typ. / <0.15%Rd + 0.05Rg Guar.
    DC: ±5mA @<1A,±0.5% @ ≥1A
    Resolution1mA
    Distortion<0.05%Typ. / <0.1% Guar.
    13 Low-Level Channel Outputs
    Quantity13 Channels, 16 pin aviation socket
    Voltage outputs rangeAC 0-8V, DC 0-10V
    Current outputs rangeNominal 2mA, 10mA max transient
    Output Power≥0.5VA
    Accuracy(0.01~0.8 Vrms):<0.05% Typ. / <0.1% Guar.
    (0.8~8 Vrms):<0.02% Typ. / <0.05% Guar.
    Resolution0.25mV
    Distortion(THD%)<0.05%Typ. / <0.1% Guar.
    Frequency & Phase Angle
    Frequency RangeDC~1KHZ, 3KHZ transient
    Frequency Accuracy±1ppm
    Frequency Resolution0.001Hz
    Phase Range-360°~360°
    Phase Accuracy<0.05°Typ. / <0.1° Guar. 50/60Hz
    Phase Resolution0.001°
    IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function)
    Fiber Ports

    2×100Base-FX Full Duplex,LC type


    (Optional to 10/100Mbit, Ethernet RJ45 type)

    Fiber Type62.5/125um (Multiple optical fiber, Orange Red)
    Wavelength1310nm
    Transmit Distance>1Km
    Indicator

    Spd Green(light):Valid connection


    Link/Act Yellow(Blinking): Data exchanging

    Note: All hardware of this module are ready for active.
    Aux. DC Voltage Source(Battery simulator)
    Range0~350V @ 140W max
    Accuracy0.5%Rg Guar.
    Binary Input
    Quantity8 pairs
    Typewet/dry, measurement
    Threshold10~600Vdc or potential free, Programmable
    Time resolution100us
    Debounce time0~25ms(Software Controlled)
    Time rangeInfinite
    Time errors±1ms @ 0.001~1s, ±0.1% @>1s
    Galvanic isolation4 isolated with each 2 pairs
    Binary Output(Relay Type)
    Quantity4pairs
    TypePotential free relay contacts,software controlled
    Break Capacity ACVmax: 400Vac / Imax:8A / Pmax:2500VA
    Break Capacity DCVmax: 300Vdc / Imax:5A / Pmax:150W
    Binary Output (Semiconductor Type)
    Quantity4pairs
    TypeOpen-collector, 14 pin Aviation socket
    Break Capacity DC

    5~15Vdc / 5mA, 10mA max


    AC not permit

    Response time100us
    Synchronization
    Synchronization Mode GPS, SMA type antenna connector / IRIG-B / FT3 IEEE1588
    Power supply & Environment
    Nominal Input Voltage100~240Vac
    Permissible Input Voltage85~264Vac, 125~350VDC
    Nominal Frequency50/60Hz
    Permissible Frequency45Hz~65Hz
    Power Consumption1500 VA max
    Connection TypeStandard AC socket 60320
    Operating Temperature-10℃~55℃
    Storage Temperature-20℃~70℃
    Humidity<95%RH, non-condensing
    Others
    PC ConnectionRJ45 Ethernet, 10/100/1000M
    Grounding Terminal4mm banana socket
    Weight18Kg
    Dimensions(W×D×H)468×375×164(mm)

    Optional Modules


    DC Measurement Input (Transducer calibrator)


    ◆ Voltage input


    Range: 0~±10V dc


    Max Input: ±11V dc


    Accuracy: <0.02% rg Typ. / <0.05% rg Guar.


    Input Impedance: 1M ohm


    ◆ Current Input


    Range: 0~±1mA / 1~20mA, auto range


    Max Input: 600mA


    Accuracy: <0.02% rg Typ. / <0.05% rg Guar.


    Input Impedance: 15 ohm


    AC / DC Measurement Input( Standard meter )


    ◆ Input Quantity: 8 channels (blend with binary input pairs).


    ◆ Voltage rang: 0~600Vrms (Rg: 0.1V,1V,10V,60V,600V).


    ◆ Voltage accuracy: <0.1% Rg


    ◆ Current range: 0~5Arms (Clamp input, 30Arms optional).


    ◆ Current accuracy: <0.1% Rg.


    ◆ Sample rate: 10KHz.


    ◆ Input impedance: 600KΩ


    ◆ Frequency range: 45~65Hz, Accuracy<0.01Hz.


    ◆ Phase accuracy: 0~360°,<0.2° Typ.


    Transient Recorder


    ◆ Input Quantity: 8 input channels (blend with binary input pairs).


    ◆ Recorder time: Max 50 Sec.


    Energy Meter Calibration


    ◆ Sensor Usage: Mechanical meters / Electronic meters.


    ◆ Sensor Output: High level : >4.5V, Low level: <0.2V.


    ◆ Pulse Input: 1 pulse input port.


    ◆ Pulse Range: 500KHz pulse input Max.


    ◆ Pulse Output: 1 Transistor output, Open-collector, 5-15Vdc/5mA.

    Quality K3166i Protective Relay Tester / Protection Relay Test Equipment  for sale
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Kingsine Electric Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Protection Relay Testing products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 burrillandco.com. All rights reserved.