Ask Lasest Price | |
Brand Name : | LENZE |
Certification : | CE |
Model Number : | EVF9322-EV |
Payment Terms : | T/T, Western Union, MoneyGram |
Supply Ability : | 100pcs/week |
Delivery Time : | in stock |
transfers of the engineering data. The use of an Ethernet CP (CP 1543-1) provides the user with additional access protection | |
y means of a firewall and/or the option of secured VPN connectionsThe fail-safe CPUs are intended for users who want to implement demanding standard and | |
fail-safe applications both centrally and distributed. These fail-safe CPUs allow the processing of standard and safety programs on a single |
CPU. This allows fail-safe data to be evaluated in the standard
user program. The integration
provides the system advantages and the extensive functionality of
SIMATIC also for fail-safe
applications.
The fail-safe CPUs are certified for use in safety mode up to:
● Safety class (Safety Integrity Level) SIL 3 according to IEC
61508:2010
● Performance Level (PL) e and Category 4 according to ISO
13849-1:2006 or according to
EN ISO 13849-1:2008
Additional password protection for F-configuration and F-program is
set up for IT security.
Design and handling
All CPUs of the SIMATIC product series feature a display with plain
text
information. The display provides the user with information on the
order numbers, firmware
version, and serial number of all connected modules. In addition,
the address of the CPU
and other network settings can be adapted locally without a
programming device. Error
messages are immediately shown on the display in plain text, thus
helping customers to
reduce downtimes.
Uniform front connectors for all modules and integrated potential
jumpers for flexible
formation of potential groups simplifies storage. Additional
components such as circuit
breakers, relays, etc., can be installed quickly and easily, since
a DIN rail is implemented in
the rail of the . The CPUs of the SIMATIC product series can be
expanded
centrally and modularly with signal modules. Space-saving expansion
enables flexible
adaptation to each application.
The system cabling for digital signal modules enables fast and
clear connection to sensors
and actuators from the field (fully modular connection consisting
of front connector modules,
connection cables and I/O modules), as well as simple wiring inside
the control cabinet
(flexible connection consisting of front connectors with assembled
single cores).Integrated system diagnostics is enabled by default
for the CPUs. The different types of
diagnostics are configured instead of programmed. System
diagnostics information is shown
uniformly and in plain text on the display of the CPU, in STEP 7
(TIA Portal), on the HMI and
on the Web server, even for alarms related to drives. This
information is available in RUN
mode, but also in STOP mode of the CPU. The diagnostics information
is updated
automatically when you configure new hardware components.
The CPU is available as a central interrupt server for 3 languages.
The CPU, STEP 7
(TIA Portal) and your HMI guarantee data consistency. You can sk
the various engineering
steps, just load it into the CPU. The maintenance work is easier.
2.3 Properties
The hardware of the CPU 1511C-1 PN consists of a CPU part, an
analog on-board I/O
module (X10) and a digital on-board I/O module (X11). When
configured in the TIA Portal,
the compact CPU therefore occupies a single shared slot (slot 1).
The properties of the CPU part, the analog on-board I/O and the
digital on-board I/O can be
found in the subsections below. The following accessories are
included in the scope of delivery and can also be ordered
separately as spare parts:
● 2 x front connector (push-in terminals) including cable ties
● 2 x shield clamp
● 2 x shield terminal
● 2 x infeed element (push-in terminals)
● 2 x labeling str
● 2 x universal front cover
For more information on accessories, refer to the , ET 200MP system
manual The CPU 1511C-1 PN has the following technical properties:
● Communication:
– Interfaces
The CPU 1511C-1 PN has a PROFINET interface (X1) with two ports (P1
R and
P2 R). It supports not only PROFINET basic functionality but also
PROFINET IO RT
(real time) and IRT (isochronous real time), which means you can
configure
PROFINET IO communication or real time settings on the interface.
Port 1 and port 2
can also be used as ring ports for configuring redundant ring
structures in Ethernet
(media redundancy).
PROFINET basic functionality supports HMI communication,
communication with the
configuration system, communication with a higher-level network
(backbone, router,
) and communication with another machine or automation cell.
You can find more information on "PROFINET IO" in the online help
of STEP 7
(TIA Portal) and the PROFINET Function Manual OPC UA
With OPC UA, data is exchanged via an open and vendor-neutral
communication
protocol. The CPU, as OPC UA server,ntegrated Web server:
A Web server is integrated in the CPU. The Web server enables
monitoring and
administering of the CPU by authorized users over a network.
Evaluations, diagnostics,
and modifications are thus possible over long distances. All you
need is a Web browser.
With the Web server, you can read out the following data from the
CPU and, in some
cases, modify and write back the data to the CPU.
– Start page with general CPU information
– Identification information
– Contents of the diagnostics buffer
– Querying module information
– Firmware update
– Alarms (without acknowledgment option)
Information about communication
– PROFINET topology
– Tag status, writing tags
– Watch tables
– Memory usage
– User pages
– Data logs (if used)
– Online backup and restoration of the configuration
– Diagnostics information for the Motion Control technology objects
– Display of trace recordings stored on the SIMATIC memory card
– Readout service data
– Basic websites
– Display of the Web server in 3 project languages, for example,
comments and
message texts
– Reces
– User pages● Supported technology:
– Counting, measuring, position detection and pulse generators
The technology functions high-speed counting, measuring, position
detection and
pulse generators (PWM/frequency output/PTO) are integrated in the
compact CPU.
For more information on integrated technology functions, refer to
the section
Technology functions.
– Motion Control
Through technology objects, the Motion Control functionality
supports speedcontrolled
axes, positioning axes, synchronous axes and external encoders,
cams,
cam tracks and probes as well as PLC open blocks for programming
the motion
control functionality.
For more information about Motion Control, refer to the section
Technology functions.
For a detailed descrtion of the use of motion control and its
configuration, refer to the
Motion ControlYou can also use the TIA Selection Tool or the SIZER
to create or configure axes.
– Integrated closed-loop control functionality
- PID Compact (continuous PID controller)
- PID 3Step (step controller for integrating actuators)
- PID Temp (temperature controller for heating and cooling with two
separate
actuators)
● Trace functionality:
– The trace functionality supports troubleshooting and optimization
of the user program,
especially for motion control and closed-loop control applications.
For more information on "Trace", refer to the Using the trace and
logic analyzer● Integrated system diagnostics:
– The system automatically generates the alarms for the system
diagnostics and
outputs these alarms via a PG/PC, HMI device, the Web server or the
integrated
display. System diagnostics is also available when the CPU is in
STOP mode.Integrated security:
– Copy protection
Copy protection links user blocks to the serial number of the
SIMATIC memory card or
to the serial number of the CPU. User programs cannot run without
the corresponding
SIMATIC memory card or CPU.
– Know-how protection
The know-how protection protects user blocks against unauthorized
access and
modifications.
– Access protection
Extended access protection provides high-quality protection against
unauthorized
configuration changes. You can use authorization levels to assign
separate rights to
different user groups.
– Integrity protection
The system protects the data transferred to the CPU against
manulation. The CPU
detects incorrect or manulated engineering data.
● Additional supported functions:
– PROFIenergy
For information on "PROFIenergy", refer to the PROFINET The
following figure shows the analog on-board I/O (X10) of the CPU
1511C-1 PNThe analog on-board I/O has the following technical
properties:
Friendly Links: www.everychina.com