OLYMPUS A-4801A VIDEOLAP LAPAROSCOPE, 10MM,0°, AUTOCLAVABLE WSTERILIZATION CASE
OLYMPUS A-4801A VIDEOLAP LAPAROSCOPE, 10MM,0°, AUTOCLAVABLE WSTERILIZATION CASE Description: Brand Name: OLYMPUS Name: OLYMPUS A-4801A VIDEOLAP LAPAROSCOPE PN: A-4801A Notes from company: Order: Medical parts and equipment with bulk stock and competitive ......
Guangzhou YIGU Medical Equipment Service Co.,Ltd
|
Tmteck Universal Mini Wheel Encoder Olympus For Ndt Standard Pa Wedges
...OLYMPUS NDT standard PA wedges FEATURES Waterproof Small dimensions Encoder resolution is engraved on the wheel Removable encoder wheel Double O-ring tire for better adherence Metallic strain relief for cable protection Spring-loaded pin for encoder attachment Two M3 threaded holes on top of the casing......
TMTeck Instrument Co., Ltd
|
Olympus CF-Q260 Flexibility Adjustment Ring
... to be changed incrementally by manipulating a flexibility adjustment ring. This innovative feature allows the scope to be adjusted on a case-by-case basis, to meet the unique anatomical needs of the patient and the handling preferences of the physician....
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
|
OLYMPUS A-4801A Video Lap Laparoscope 10MM 0° Autoclavable Sterilization Case
OLYMPUS A-4801A VIDEOLAP LAPAROSCOPE, 10MM,0°, AUTOCLAVABLE WSTERILIZATION CASE YIGU Med Feature Yigu med is a professional medical equipment service and accessories/parts selling company Operating with over 10 years ......
Guangzhou YIGU Medical Equipment Service Co.,Ltd
|
OLYMPUS CF-H190L COLONOSCOPE SN:OLYMPUS CF-H190L COLONOSCOPE SN: 240**** FOR REPAIR
OLYMPUS CF-H190L colonoscope SN: 240****. Test results: 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending ......
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
|
Repair case of Olympus CV-190 processor
Olympus CV-190 processor. Fault: Normal working, but error for white balance. The chips missing on main control panel (PN:DV641901), and short circuit. Solution: Repair main control panel. We provide trading and service of Ultrasound Unit/Transduce,Dynamic......
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
|
No image and leakage of Olympus CF-240AI Colonoscope for repair
Olympus CF-240AI Colonoscope for repair, SN:2521***. Fault: No image. Leakage, insert tube, biopsy channel, light guide tube and light bundle aging,no angle, knob tight,etc. Solution: Grade A repair. (Grade A repair is include replace CCD,light guide tube,......
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
|
No angle and leakage of Olympus CF-240L Colonoscope for repair
Olympus CF-240L Colonoscope for repair, SN:2900***. Fault: Leakage, glass of light bundle blur, rubber leak, angle not enough,image fuzzle,objective lens scratch,etc. Solution: Replace rubber, objective lens, C cover. Adjust the angle. Repair time: 5 ......
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
|
Olympus BF-1T40 Bronchoscope for repair
Olympus BF-1T40 Bronchoscope for repair, SN:1221***. Fault: insert tube bited, rubber leak,image fuzzle, image bundle break,etc. Solution: Grade A repair. (Grade A repair is include replace image bundle,light guide tube,insert tube,forcept tube and rubber......
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
|
Olympus CHF-P20Q endoscope for repair. SN: 272****
Olympus CHF-P20Q endoscope for repair. SN: 272**** Fault: Insert tube cracked; Rubber leakage; Image with black point and cracked; Angulation tight; Biopsy tube aging Solution: Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil ......
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
|