| Sign In | Join Free | My burrillandco.com |
|
.... It can measure direct current (DC), alternating current (AC), and pulse current. The detailed specifications are as follows: Applications: Industrial Automation: Used in speed drives, servo systems, and hi...
...Current Output Single-Axis Inclinometer Simple-Use 4-20mA/0-20mA/0-24mA Optional Introduction: BWL318 is a low-cost single axis inclination sensor with current output. It directly outputs the horizontal incl...
Description of 4-20ma signal generator loop process calibrator: This instrument can output/measurement the following signals:Current signal/Voltage signal/mV signal;8 kinds of thermocouple(E,K,B,S,T,R,J,N) sign...
BD-AI Series Single Phase current Transducer Measurement AC current Overload: 1.2 times of rated value Analog Output: DC 0-5V/0-10V/0-20mA/4-20mA Characteristic Communication Application RS485 (Modbus-RTU) Powe...
Technical Parameter Input AIAC Single Phase Output IDirect Current e.g. 4-20mA ; VDirect Current Voltage e.g. DC0-5V Power Supply DC12V or DC24V Measuring Aperture 20-20mm, 50-50mm, Communication RS485 ...
... AC ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU) ● Power Supply: 85~265V AC(50Hz) or 100~350V ......
...series 8 inputs channel Current/Voltage signal to RS485/232 Converter, 24 Bits AD data acquisition Features: Eight analog signal acquisition, isolated converter RS-485/232 output 24-bit AD converter, accurac...
...Current Sensor 600A , Open Loop Current Transducer hall effect current sensor CS600KF1 hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic i...
...load resistance: RL ≤ 800Ω (output is current signal); RL ≥ 1MΩ (output is voltage signal) Output ripple: ≤10mVp-p Basic parameters Number of channels: two in and two out (THS-IP5XX) Power supply: DC24V, vol...
...20mA; 0-20mA; 0-75mV, 0-5V; 0-10V Distribution voltage: 24V, (maximum drive current 30mA) Input impedance: current input: ≤50Ω; voltage input: ≥300KΩ Output Output signal: 4- 20mA; 0-20mA; 0-5V; 0-10V Output...
... method ,with a galvanic isolation between primary and secondary circuit, the size of primary not affect test precision, no matter the location of primary in the hole of current sensor,...
... method ,with a galvanic isolation between primary and secondary circuit, the size of primary not affect test precision, no matter the location of primary in the hole of current sensor, It can...
...Current Transducer Open Loop Device CS1000BF Product Description hall current sensor open loop hall effect is an open loop device based on the measuring principle of the hall effect, with a galvanic isolatio...
... based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. The current sensor provides accurate electronic measurement of DC, AC or pulsed currents...
.../secondary side electricity The electrical insulation between the circuits can measure DC, AC and pulse current. 2. Electrical parameters Rated current (in) : 100a.t rms (rated) Measuring range: 0~±150a.t (d...
... or Hall effect type. Using the zero-flux method (feedback system), it continuously controls the magnetic flux in the sensor core to zero. The current required to balance the zero flux is proportional to the...
... are as follows: Basic Parameters: Rated Current: 100A RMS (at 25℃). Measurement Range: ±300A. Measuring Resistance: At 70℃ (with ±15V, ±25A.t max): Min. 54ohm, Max. 360ohm. Analog Output Current: 25mA. Turn...
...Loop Current Sensor Features: CSNS200M-002S Closed-loop Current Sensor Measurement Equipment, the main parameters are as follows: Core parameters Rated current: 200A (rms value of AC) Measurement range: 0 ...