... Column High - voltage Vacuum Circuit Breaker General The vacuum circuit breaker on the ZW32 column is an outdoor 11kV and 50Hz AC power distribution equipment, which is mainly used to shut down and turn ove...
... low voltage terminal distributionsystem. RCBO is equal with MCB+RCD function;The rated current can be adjusted as per the Customers' request; It is usedfor electric shock ......
...Low-Voltage DC Miniature Circuit Breaker Model NO.: SBS-L-E Features: 100% Polycarbonate (PC) Enclosure; Inflammable Retardant; UV Resistant; Customization Acceptable; 5-year warranty Product Pictures: Compa...
... 4p Residual Current Circuit Breaker with Over Load Protection with CE, CB, SAA Approval and Testing Report 10-40A 30mA GENERAL RCBO is mainly used in AC 50Hz(60Hz), rated voltage 230/400V, rated current 6A ...
... as an arc extinguishing medium. This allows for high efficiency in preventing partial discharge, ensuring that the circuit breaker can operate at optimal conditions. The use of vacuum also eliminates the ne...
... function, short beep for every correct step, three continuous beeps reminding wrong operation 4. Single Chip Microcomputer as the core of control circuit, low voltage control circuit made of integrated circ...
...Circuit Breaker Timing Test Equipment High Voltage Tester Small Size 1. Product Name:Circuit breaker analyzer HYGK-307 HYGK-307 Introduction: Test mechanical characteristics of circuit breakers, load switche...
...voltage vacuum circuit breaker The main technical parameters Serial number name unit data 1 Rated voltage KV 12 2 Rated frequency Hz 50 3 Rated insulation level 1min power frequency withstand voltage kA On t...
24kv Vacuum Are - extinguishing Chamber High Voltage AC Vacuum Circuit Breaker NINGBO TIANAN (GROUP) CO., LTD. Overview VT19-24indoor HV vacuum circuit breaker is used in three-phase AC electric system of 50HZ,...
VS1(ZN63A)-12 Indoor AC High Voltage Vacuum Circuit Breaker NINGBO TIANAN (GROUP) CO., LTD. The structure of vacuum arc-extinguish room Vacuum arc-extinguish room is the core parts from circuit breaker to suppo...
... , 3150A and 4000A contact box , club contact , fix contact, arm contact and jaw contact . 630A and 1250A VS1 circuit breaker . 630A and 1250A ZN85-40.5 circuit breaker . 12KV and...
.... Installed with standard DIN rail, it is convenient and easy in usage. It is mainly used in the line of AC 50/60Hz, rated working voltage to 240V/415V, and rated current to 63A as protection against...
...voltage vacuum circuit breaker vcb 12KV 10kv 11kv 630A vacuum circuit breaker can be used in the AC 50Hz, rated voltage 12kV three-phase electric net. Break and close load, with overload and short-circuit pr...
...voltage Vacuum Circuit Breaker General: ZN28G-12 indoor AC high-voltage vacuum circuit breaker is an indoor switching equipment with three-phase AC 50HZ and rated voltage 12KV. It is used for the protection ...
...Circuit Breaker 6A TO 63A General STD7 series high breaking capacity mini circuit breaker (MCB)miniature circuit breaker is mainly used for protection against overload and short circuit under the rate voltag...
...circuit breaker power station type product information Product name: ZW7-40.5 outdoor vacuum circuit breaker Category: high voltage components Product introduction: ZN7-40.5 outdoor high-voltage true master ...
...Circuit Breakers 1. Application VKM1 series of molded case circuit breakers are applied to frequently changeover the circuit of rated insulation voltage of 800V (VKM1-63 is 500V), AC 50/60Hz, rated voltage 6...
...Circuit Breaker Type C MCCB Power Circuit Breaker Application DZ20 series molded case circuit breaker andDZ20□W no-flashover circuitbreaker(hereinafterreferredtoascircuitbreaker)aresuitablefordistributinglin...
...Voltage Vcb Circuit Breaker / Outdoor Vacuum Breaker Reclosing Operation Introduction VS1 vacuum circuit breaker is suitable for reclosing operation and has high operation reliability and service life. VS1 v...