| Sign In | Join Free | My burrillandco.com |
|
...°C Maximum temperature of the conductor during short-circuit (less than 5 seconds) shall not exceed 250°C The ambient temperature under installation should not be lower than 0°C The bending radius of the xlp...
...°C Maximum temperature of the conductor during short-circuit (less than 5 seconds) shall not exceed 250°C The ambient temperature under installation should not be lower than 0°C The bending radius of the xlp...
...Technical data Rated voltage: 0.6/1kV Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions. Min. Ambient Temp.: The cable shall be pre heat...
Medium Voltage Xlpe Insulation Cable / Electrical Power Cable Iec 60502 Construction Conductor : Compact stranded Aluminum conductor, Cl.2 as per IEC 60228 Conductor Screen: Semi-conductor Insulation : XLPE (cr...
...Cable , XLPE Power Cable 0.6KV / 1kV Applications: XLPE Insulated Cable is used as power distribution and transmission line at rated voltage 0.6/1KV. Construction: Conductor Copper Conductor as per IEC 60228...
...XLPE Power Cable XLPE Power Cable Application: 1) These cables are most suitable for direct burial or for installation on trays or ducts, Where there is a risk of mechanical damage, armoured cables should ...
...60332-3-24 Flame Retardant Cat. C Technical data Rated voltage: 0.6/1kV Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions. Min. Ambient ...
...XLPE Electrical Cable YJV Type XLPE Power Cable For Industrial Plants & Captial Construction IEC 60502-1 Cables 600/1000V, XLPE Insulated Power Cables according to IEC 60502-1 Applications of 0.6/1KV Copper ...
...Voltage Insulated Power Cable Multicore , Low Voltage Electrical Wire 1. Standard of XLPE Cable: According to GB12706( Equal to IEC60502)Also can do by standard of ASTM,BS,DIN and AS/NZS or other standards a...
...Voltage Insulated Power Cable Multicore , Low Voltage Electrical Wire 1. Standard of XLPE Cable: According to GB12706( Equal to IEC60502)Also can do by standard of ASTM,BS,DIN and AS/NZS or other standards a...
...XLPE Medium Voltage Power Cable 1. Feature 1.Available Standards: IEC. UL, ASTM, GB, JIS 2. Brand: SHUANG XIN 3. Conductor Material: Cu, Al or as required. 4.Application: 11KV Medium Voltage Armoured Power C...
12/20KV CU/SC/XLPE/SC/CTS/AWA/PVC 1x150mm2 Single core Medinum Voltage Armored Power Cable APPLICATIONS: 12/20KV CU/SC/XLPE/SC/CTS/AWA/PVC 1x150mm2 Single core Medinum Voltage Armored Power Cable are with low d...
... with polyethylene material and used for transmission of electricity. It has a wide range of cross-sectional area, from 1.5mm2 to 1000mm2. The sheath material of XLPE Insulated Power Cable can be PVC, PE or ...
... Size & Construction Type of Insulation Armored or unarmored. If armor, the armor type & material The Requirement of Sheath Length of Cable & Packing Requirement Other Requirement Technical data Rated voltag...
...XLPE Power Cable , XLPE Electrical Cable 600 / 1000 V Electrical characteristics ------------------------------------------------------- –Rated voltage Uo/U (Um): 600 / 1000 V –Maximum current rating air 30°...
...XLPE Power Cables Applications: Used for Power transmission and distribution line with voltage rated at 35kv and below. For Layling indoors and outdoors. Able to bear certain traction during installation, bu...
0.6/1KV 2c Low Voltage Unarmoured Power Cable (CU/PVC/XLPE/NYY/N2XY) Nominal Area :2*1.5~2*400mm2 according to IEC 60502-1 Description: 0.6/1KV XLPE Insulated Cables (Unarmoured) IEC60502,IEC60228,GB/T 12706.1-...
0.6/1KV 2c Low Voltage Unarmoured Power Cable (CU/PVC/XLPE/NYY/N2XY) Nominal Area :2*1.5~2*400mm2 according to IEC 60502-1 Description: 0.6/1KV XLPE Insulated Cables (Unarmoured) IEC60502,IEC60228,GB/T 12706.1-...
... , the urban construction site and transformer wiring occasion etc.. It improves the safety and reliance of electrified wire netting. Characteristics of Overhead Insulated Cable 1) Rated voltage U0/U :0.6/1 ...