    AC 220V 50HZ SV5Q Auto Workshop Equipment Exhaust Gas Analyzer

    Ask Lasest Price
    Brand Name : HIPPOTECH
    Price : Factory price
    Delivery Time : Within 1-2 working days upon received payment
    Payment Terms : T/T, MoneyGram, Paypal
    Supply Ability : 200 sets/week
    • Product Details
    • Company Profile

    AC 220V 50HZ SV5Q Auto Workshop Equipment Exhaust Gas Analyzer

    AC 220V 50HZ SV5Q Auto Workshop Equipment Exhaust Gas Analyzer

    Description:

    SW-5Q automobile exhaust gas analyzer, in accordance with non-light-disguising infrared absorption method, via micro-computer analysis, directly measure the thickness of HC, CO and CO2 in the exhaust gas of vehicles

    and inspect the density of NO and O2 via Electrochemical sensor so as to calculate excess air coefficient λ.

    The analyzer introduces advanced foreign technology. It is composed of complete imported machinery cores,

    boasts the advantages of accuracy measurement, high endurance and speed. As an Intelligent Equipment,

    it is equipped with Microprocessor, LCD and Chinese language interface. Besides, it also has optional

    equipments such as Induction Tachometer, temperature sensor, inner Micro Printer for customers to purchase.

    The newly-added Storage function can detect Engine's speed and Lubricant's Temperature while measuring

    tail gas, then store and print the results.


    Besides detecting functions, its computer programs on detection under Two-speed Idle, written by us

    according to limits and measurement methods for exhaust pollutants from vehicles equipped ignition

    engine under two-speed idle conditions and simple driving mode conditions, can control the process of

    detection automatically. So it's convenient to use. The analyzer has small size, light weight, storage of

    500 groups' data of exhaust gas measurement. Particularly it is suitable for check along the road.

    It's utilized for auto-manufacturing factories, vehicle inspection stations and garages.

    The main technical parameters:

    1. Environmental temperature

    Temperature:-5~40℃
    humidity: ≦95%
    Air pressure: 70.0~106kPa
    Power: AC 220V±10%;50Hz±1Hz

    2.Measuremnt scope:
    HC: 0~10000 10-6(ppm)vol
    CO: 0~10.0 10-2(%)vol

    CO2 : 0~20.0 10-2 (%) vol
    O2 : 0~25.0 10-2(%)vol 
    NO: 0~5000 10-6(ppm)vol  
    oil temperature:0~120℃
    rotate speed: 0~10000rpm

    3.Sampling method:
    tail gas: sampling directly .
    The length of sampling tube: 5m,the length of probe:900mm.

    Oil temperature:inserting the head of thermo scope into the staff gauge of engine lubricant, the length of

    which is the same as that of oil staff gauge; blocking with rubber plug to plug up engine oil from ejecting:

    length of lead: 5m.

    Rated rpm: Non-contact measurement method. Less than 20cm to the petrol high-voltage flexible cord,

    measuring petrol rotate speed.


    4.preheat time:10mins

    5.resolution:
    CO: 0.01% vol  
    HC: 1ppm vol normal hexane equivalent
    CO2: 0.01% vol  
    O2 : 0.01%vol

    NO: 1ppm vol
    rate speed: 1rpm
    oil temperature: 0.1℃

    6.indicated error:
    CO: ±0.06% vol or±5% relative error.
    HC: ±12ppm vol or ±5% relative error

    CO2 : ±0.5% vol or ±5% relative error
    O2 : 0.1% vol or±5% relative error

    NO: ±25ppm vol or±5% relative error
    rate speed: ±10rpm(0~10000rpm) ±1% measured value (>10000rpm)

    7.Stability:after preheating, zero excursion and measurement distance excursion in 4 hours should

    not be over the allowance value of sample value error

    8.Repetitiveness: ≤1/2 of absolute of the allowed sample value error

    9.Output signal: Number volume: RS232 serial massage exit.

    Quality AC 220V 50HZ SV5Q Auto Workshop Equipment Exhaust Gas Analyzer for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Hippo Technology Co.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Auto Workshop Equipment products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0