Sign In | Join Free | My burrillandco.com |
|
Ask Lasest Price | |
Brand Name : | SOROTEC |
Certification : | CE,ROHS,ISO9000 |
Delivery Time : | Within 15-30days after receiving your 30% TT deposit |
Payment Terms : | 30% TT in advance, the balance before shipping |
Supply Ability : | 10000PCS/Month for Inverter and line Interactive UPS; Advance 3000PCS/Month for Online UPS |
Model Number : | GP9335C Series 120-800KVA |
Possess Date Center and Local area Networks function UPS Series 160KVA / 3Ph in / out 12p / 6p
Key Features:
1. On-Line Dual Conversion, fully isolating the influences of power grid pollution and power failure from utility power supply and diesel generator to load
2. Rated at 0.9 output power factor, more applicable to server
computer and network center that use PFC technology in a large
scale, and deliver more Active power than conventional UPS
3. Use advanced 6th generation DSP and full digital control
technologies to realize higher system stability
4. Multi input harmonic suppressing technology improves the utility
rate of electric Power Output isolation transformer with zero phase
shift reduces the influences of Neutral to Ground voltage and load
harmonic current to inverter
5. Extra strong capability to withstand output overload and short
circuit, ensuring the system stability and system safety under
extreme conditions
6. Advanced distributed active parallel technology can realize
parallel operation of six UPS units without the need of centralized
bypass cabinet
7. Extra wide input voltage and frequency range make it adapt to
severe power grid environment
8. Standard input/output filter improves the system EMC performance
9.Intelligent battery management maintains battery automatically to
prolong the battery life
10.6 inch extra large LCD that can display 12 language(Chinese.English.Russian.Spanish.French and so on
11. Layered independently-sealed ventilation channel and redundant
fan, circuit boards with protective paints and a dust filter
embedded make it highly efficient to dissipate heat and protect the
product effectively under severe environment.
Applications:
Mainly used in large IDC rooms, bank/securities settlement center,
communication network management center, semiconductor product
lines and large automation production and its control system.
According to the special needs of users was improved, and used in
large sports venues, conference room, theater and highway and
railway tunnels metal halide lamp lighting system.
Technical Specifications of Online UPS GP9335C 120-800KVA
Model | GP9335C 120-800KVA | |||||||||||
Rectifier Type | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | ||
Rated Nominal | 120KVA/108KW | 160KVA/144KVA | 200KVA/180KW | 300KVA/270KW | 400KVA/36W | |||||||
Rated input voltage | 380/400/415VAC 3-phase 4-wire | |||||||||||
Rated frequency | 50/60HZ | |||||||||||
Input parameters | ||||||||||||
Input voltage range | ±25% | |||||||||||
Input frequency range | 45Hz~65Hz | |||||||||||
Input soft start function | 0-100% 5-300settable | |||||||||||
Input power factor | >0.98(If harmonic filter is added) | |||||||||||
Input harmonic current (THDi) | <4.5%(If harmonic filter is added) | |||||||||||
Bypass | ||||||||||||
Bypass voltage range | -20%~+15% | |||||||||||
Bypass frequency range | 50/60HZ±10% | |||||||||||
Output parameters | ||||||||||||
Inverter output voltage | 380/400/415VAC 3-phase 4-wire | |||||||||||
Voltage stability | ±1%(Steady status), ±3%(Transient status) | |||||||||||
Frequency | 50/60Hz | |||||||||||
Mains power synchronization window | ±5% | |||||||||||
Actually measured frequency accuracy (internal clock) | 50/60Hz±0.01Hz | |||||||||||
Output power factor | 0.9(Output 90kW per 100kVA) | |||||||||||
Transient response time | <5ms | |||||||||||
Inverter overload capability | At 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s | |||||||||||
Short circuit current from inverter | 3ph 1.5ln for 5seconds, 1ph 2.9ln for 5seconds | |||||||||||
Maximum Bypass capability | 1000% for 100ms | |||||||||||
Phase shift | With 100% balanced load | <1° | ||||||||||
With 100% imbalance load | <1° | |||||||||||
Total harmonic | 100% linear load | <1% | ||||||||||
100% non-linear load | <3% | |||||||||||
System efficiency (full load) | Up to 94% (inverter efficiency is up to 98%) | |||||||||||
Rectifier output parameters | ||||||||||||
Charger output voltage stability | 1% | |||||||||||
DC ripple voltage | ≤1% | |||||||||||
Operating environment | ||||||||||||
Operating temperature range | 0~40℃ | |||||||||||
Storage temperature | -25~70℃(Without battery) | |||||||||||
Relative humidity | 0~95% No condensation | |||||||||||
Maximum operating height | ≤Elevation 1000m, for elevation above 1000m, derate by 1% for every increase of 100m | |||||||||||
Noise (1m) | 58-68dB | |||||||||||
Protection level | IP20 | |||||||||||
Standard | Safety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3 | |||||||||||
Physical parameters | ||||||||||||
Weight (kg) | 980 | 1420 | 1200 | 1750 | 1350 | 2000 | 1600 | 2200 | 2100 | 2750 | ||
Width(mm) | 900 | 1250 | 1250 | 1640 | 1250 | 1640 | 1640 | 2280 | 2280 | 2280 | ||
Depth (mm) | 855 | 855 | 855 | 855 | 855 | 855 | 855 | 855 | 855 | 855 | ||
Height (mm) | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 |
Follow standard of GB/IEC regulation: EMC:GB7260.2/IEC62040-2
GB/17626.2~5/IEC61000-4-2~5 SAFETY:GB4943
Note: Product specifications are subject to change without further