Sign In | Join Free | My burrillandco.com
Home > Grinder >

MFT-900 Integrity Test Machine Zetron Leak And Seal Strength Tester Non Destructive Testing

    Buy cheap MFT-900 Integrity Test Machine Zetron Leak And Seal Strength Tester Non Destructive Testing from wholesalers
     
    Buy cheap MFT-900 Integrity Test Machine Zetron Leak And Seal Strength Tester Non Destructive Testing from wholesalers
    • Buy cheap MFT-900 Integrity Test Machine Zetron Leak And Seal Strength Tester Non Destructive Testing from wholesalers
    • Buy cheap MFT-900 Integrity Test Machine Zetron Leak And Seal Strength Tester Non Destructive Testing from wholesalers
    • Buy cheap MFT-900 Integrity Test Machine Zetron Leak And Seal Strength Tester Non Destructive Testing from wholesalers
    • Buy cheap MFT-900 Integrity Test Machine Zetron Leak And Seal Strength Tester Non Destructive Testing from wholesalers
    • Buy cheap MFT-900 Integrity Test Machine Zetron Leak And Seal Strength Tester Non Destructive Testing from wholesalers

    MFT-900 Integrity Test Machine Zetron Leak And Seal Strength Tester Non Destructive Testing

    Ask Lasest Price
    Brand Name : Zetron
    Model Number : MFT-900
    Payment Terms : L/C, D/A, D/P, T/T
    Delivery Time : for 1-50 pcs, 7 work days; more than 50 pcs, to be negotiated
    • Product Details
    • Company Profile

    MFT-900 Integrity Test Machine Zetron Leak And Seal Strength Tester Non Destructive Testing

    MFT-900 Packaging Leak Tester


    OVERVIEW

    Packaging Tightness Tester, detection type: vials ampoules, pre filled syringes, cartridge bottles, infusion bagsBFS packaging, pharmaceutical industry sealing integrity leak detection solutions. compliance fDA 13287 standard: meet one of USP 1207 test methods: non-destructive testing method.

    FEATURES

    ・Comply with USP <1207>, ASTM F2338 standards and FDA standards.

    Semi-automatic detection, suitable for small batch and multi-variety testing.

    Non-destructive non-destructive testing, high accuracy, repeatability, sensitivity.

    ・The instrument is used for vacuum pressure difference detection.

    ・The leak rate can be automatically converted into defect aperture μm.

    ・Databasestorage of test results for easy quality management.

    ・Database storage of test results for easy quality management.

    ・Touch-type man-machine interface, simple and quick operation: after setting/selecting the test program, only need to manually put in/take out the test sample.


    ADVANTAGE FUNCTION

    ・ Automatically test the flow rate and change the aperture size during the whole process.
    ・ Automatic leak flow calibration function.
    ・ Equipped with standard leaks (standard positive bottles, with third-party certification).
    ・ Four-level user authority management meets FDA 21CFR PART 11 requirements.
    ・ With audit trail function.
    ・ Split design, the test chamber is located above the host, and various test chambers can be provided according to different product types.
    ・ We also provide users with supporting services related to tightness testing, including positive bottle(mould) production, standard leak rate/annual leak verification, new sample mold customization, sample methodological parameter development and verification, etc.
    ・ The test cavity is customized according to customer needs to ensure that the test cavity is fully matched with the customer's product, and rapid and sensitive testing.


    Application
    MFT-900 is suitable for sealing integrity testing of pharmaceutical packaging to prevent moisture, oxygen, and microorganisms from contaminating products. Medicines: bottled, bagged, boxed, ampoules, vials, cartridges, prefilled needles (PFS), (BFS), (FFS), etc. Spray cans: plunger spray cans; bag-lined spray cans; "energy jacket" spray cans; flexible tube spray cans.

    SPECIFICATIONS


    Differential pressure sensor±2kpa, error≤0.5%F.S.
    Differential pressure resolution0.1pa
    Test pressure sensorError≤±1%F.S.
    Test pressure range-0.1~0.2Mpa /-0.1~0.7MPa/-0.1~1.0Mpa(operational)
    Minimum detectable aperture

    2μm ( for IV bag minimum 5μm)


    Display method10-inch touch color touch screen
    VoltageAC100V-240V, 50/60Hz, power ≤200W
    WeightHost: about 30kg
    Audit trail<=5 years of storage Multiple event logs, which can be queried according to time
    Authority managementLogin with username and password, level 4 authority, meet FDA 21CFR PART 11 requirements
    Print functionBuilt in printer
    History record<=5 years storage
    Data backupSupport U disk to export data
    InterfaceEthernet USB RS485(operational)


    Quality MFT-900 Integrity Test Machine Zetron Leak And Seal Strength Tester Non Destructive Testing for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Beijing Zetron Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Integrity Test Machine products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0