| Sign In | Join Free | My burrillandco.com | 
 | 
| Ask Lasest Price | |
| Brand Name : | B&R | 
| Model Number : | X20DM9324 | 
| Certification : | CE | 
| Price : | USD | 
| Payment Terms : | T/T | 
| Supply Ability : | 10EA | 
| Delivery Time : | 3-5 WORKING DAYS | 

X20DM9324
This module is equipped with 8 inputs and 4 outputs for 1-wire connections. The inputs are designed for sink connections, the outputs for source connections.
| I/O module | 8 digital inputs 24 VDC for 1-wire connections, 4 digital outputs 24 VDC for 1-wire connections | 
| Nominal voltage | 24 VDC | 
| B&R ID code | 0x20B9 | 
| Status indicators | I/O function per channel, operating state, module status | 
| Diagnostics | |
| Module run/error | Yes, using LED status indicator and software | 
| Outputs | Yes, using LED status indicator and software (output error status) | 
| Power consumption | |
| Bus | 0.21 W | 
| Internal I/O | 0.5 W | 
| Additional power dissipation caused by actuators (resistive) [W] | +0.21 | 
| Certifications | |
| CE | Yes | 
| UKCA | Yes | 
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X | 
| UL | cULus E115267 Industrial control equipment | 
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 | 
| EAC | Yes | 
| KC | Yes | 
| Input characteristics per EN 61131-2 | Type 1 | 
| Input voltage | 24 VDC -15% / +20% | 
| Input current at 24 VDC | Typ. 3.75 mA | 
| Input circuit | Sink | 
| Input filter | |
| Hardware | ≤100 µs | 
| Software | Default 1 ms, configurable between 0 and 25 ms in 0.2 ms increments | 
| Connection type | 1-wire connections | 
| Input resistance | Typ. 6.4 kΩ | 
| Switching threshold | |
| Low | <5 VDC | 
| High | >15 VDC | 
| Insulation voltage between channel and bus | 500 Veff | 
| Variant | Current-sourcing FET | 
| Switching voltage | 24 VDC -15% / +20% | 
| Nominal output current | 0.5 A | 
| Total nominal current | 2 A | 
| Connection type | 1-wire connections | 
| Output circuit | Source | 
| Output protection | Thermal shutdown in the event of overcurrent or short circuit (see
value "Short-circuit peak current") Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads") | 
| Diagnostic status | Output monitoring with 10 ms delay | 
| Leakage current when the output is switched off | 5 µA | 
| RDS(on) | 210 mΩ | 
| Peak short-circuit current | <12 A | 
| Switch-on in the event of overload shutdown or short-circuit shutdown | Approx. 10 ms (depends on the module temperature) | 
| Switching delay | |
| 0 → 1 | <300 µs | 
| 1 → 0 | <300 µs | 
| Switching frequency | |
| Resistive load | Max. 500 Hz | 
| Inductive load | See section "Switching inductive loads". | 
| Braking voltage when switching off inductive loads | Typ. 50 VDC | 
| Insulation voltage between channel and bus | 500 Veff | 
| Electrical isolation | Channel isolated from bus Channel not isolated from channel | 
| Mounting orientation | |
| Horizontal | Yes | 
| Vertical | Yes | 
| Installation elevation above sea level | |
| 0 to 2000 m | No limitation | 
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m | 
| Degree of protection per EN 60529 | IP20 | 
| Temperature | |
| Operation | |
| Horizontal mounting orientation | -25 to 60°C | 
| Vertical mounting orientation | -25 to 50°C | 
| Derating | - | 
| Storage | -40 to 85°C | 
| Transport | -40 to 85°C | 
| Relative humidity | |
| Operation | 5 to 95%, non-condensing | 
| Storage | 5 to 95%, non-condensing | 
| Transport | 5 to 95%, non-condensing | 
| Note | Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately. | 
| Pitch | 12.5+0.2mm | 
|   | 
| Company Info. | 