    Ask Lasest Price
    Brand Name : Gnee
    Model Number :
    Certification : ISO
    Price : bargain
    Payment Terms : T/T,L/C,Paypal,Alipay,West Union and so on
    Supply Ability : 25 every month
    Delivery Time : 15days
    • Product Details
    • Company Profile

    Brazed Plate Type Heat Exchanger Anti Corrosion Compressed Fiber

    High Quality Brazed Plate Heat Exchanger Low Price With CE


    Description

    Plate heat exchanger has a variety of flow path combinations, all of which are realized by different reversing plates and different assembly methods. Flow path combination is divided into single flow, multi flow and mixed flow, should be selected according to the process requirements. In general, the media with temperature difference greater than 1.8 times the logarithmic average temperature difference should adopt multi-flow. The interplate flow rate is 0.3-0.5m /S. If the flow is too small, double or multiple flows should be used.


    Parameter

    Gasket
    material
    Temperature range (℃)Corrosion resistance


    NBR


    -20~110
    It has good corrosion resistance to chain hydrocarbon (propane, butane, etc.), mineral oil, animal and vegetable oil, aliphatic
    hydrocarbon, ethylene glycol, acid and alkali dilute solution.


    HNBR


    -20~165
    It has good corrosion resistance to chain hydrocarbon (propane, butane, etc.), mineral oil, animal and vegetable oil, aliphatic
    hydrocarbon, ethylene glycol, acid and alkali dilute solution.


    EPDM


    -50~150
    Resistant to dilute acid, alkali and salt corrosion. Suitable for hot water, saturated steam, glycol, organic acid, sodium
    hydroxide, ethanol, hexadecane, ester, etc.


    H-EPDM


    -20~165
    Resistant to dilute acid, alkali and salt corrosion. Suitable for hot water, saturated steam, glycol, organic acid, sodium
    hydroxide, ethanol, hexadecane, ester, etc.


    S-EPDM


    -20~130
    Resistant to dilute acid, alkali and salt corrosion. Suitable for hot water, saturated steam, glycol, organic acid, sodium
    hydroxide, ethanol, hexadecane, ester, etc.


    Viton


    -40~180
    Excellent corrosion resistance. It is suitable for high concentration inorganic acid-base and polar chemical medium, mineral oil,
    silicone oil and silicone resin, animal and vegetable oil, chain hydrocarbon (propane, butane, mineral oil, etc.), hydrocarbon
    chloride, fuel, non gas resistant substance, etc.
    Chloroprene rubber(CR)-50~100It is resistant to dilute non oxidizing acid and alkali.
    Silicon-65~230Corrosion resistant to dilute acid, alkali and brine.


    Compressed fiber(AFM34 SIL-4400)


    260
    Oil, water and vapor (up to 160 ℃), gas, salt solution, fuel, ethanol, organic / inorganic acids, refrigerants, hydrocarbons.


    PTFE


    -200~260
    It has excellent corrosion resistance. Except molten metal lithium, sodium, potassium, chlorine trifluoride, oxygen trichloride at
    high temperature and liquid fluorine with high flow rate, it can resist all chemical media (including concentrated nitric acid and
    aqua regia).

    Structural features of plate heat exchanger:

    1. The plate group includes a certain number of heat transfer plates, which are determined according to the needs of the heat transfer area.

    2. The gasket on the plate ensures that the flow channels are sealed against each other. Gaskets also determine the direction of fluid flow in the heat exchanger.

    3. The frame is fastened to the plate with fastening bolts.

    4. The interface for the inlet and outlet media is usually on the fixed compression plate of the heat exchanger. In the case of multi-channel, the connection port must be on the fixed compression plate.

    5. Adjacent plates form runners for hot and cold media respectively. If the two media have the same number of flow channels, 100% countercurrent flow can be achieved.

    plate heat exchanger

    plate heat exchanger

    Quality Brazed Plate Type Heat Exchanger Anti Corrosion Compressed Fiber for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Henan Gnee New Materials Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Plate Type Heat Exchanger products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0