Sign In | Join Free | My burrillandco.com
Home > Grow Lights >

AA1800H Six Lamp Atomic Absorption Spectrophotometer Automatic Switching

    Buy cheap AA1800H Six Lamp Atomic Absorption Spectrophotometer Automatic Switching from wholesalers
     
    Buy cheap AA1800H Six Lamp Atomic Absorption Spectrophotometer Automatic Switching from wholesalers
    • Buy cheap AA1800H Six Lamp Atomic Absorption Spectrophotometer Automatic Switching from wholesalers
    • Buy cheap AA1800H Six Lamp Atomic Absorption Spectrophotometer Automatic Switching from wholesalers
    • Buy cheap AA1800H Six Lamp Atomic Absorption Spectrophotometer Automatic Switching from wholesalers

    AA1800H Six Lamp Atomic Absorption Spectrophotometer Automatic Switching

    Ask Lasest Price
    Brand Name : Macylab
    Model Number : AA-1800H
    Certification : ALL OF MADE IN CHINA
    Price : TALK ABOUT IT
    Payment Terms : Western Union, MoneyGram, T/T, L/C, D/A
    Supply Ability : 100 SET/DAY
    Delivery Time : Within 6 days
    • Product Details
    • Company Profile

    AA1800H Six Lamp Atomic Absorption Spectrophotometer Automatic Switching

    1.1 Instrument Description

    AA-1800H is a multifunctional atomic absorption spectrometer with two background correction methods, D lamp background elimination and self-absorption background deduction. It is a high precision analytical instrument integrates flame atomic absorption spectrometry (abbreviated as FAAS), and hydride generation atomic absorption spectrometry (abbreviated as HG-AAS), and graphite furnace atomic absorption spectrometry (abbreviated as GFAAS), and atomic emission spectrometry (abbreviated as AES). An auto-sampler is optional to equip with graphite furnace atomic absorption spectrometry. AA-1800H is widely used in geology, metallurgy, mining, petroleum, chemical industry, mechanical, agriculture, food industry, medicine, health, antiepidemic, environmental protection, and other industries. And it is an essential high precision analytical instrument for scientific research institutes, colleges and universities, and related enterprises.


    AA-1800H can be used for analyzing metallic elements, amphoteric elements, and alkali elements. It’s a high precision analytical instrument with high performance and its determination range can be from ppb to ppt. Following are the features of AA-1800H:

    • Advanced determination of flame atomic absorption spectrometry

    It is developed by experienced professors and senior engineers who are engaged in analytical instrument industry of atomic absorption spectrometry for many years. The background correction with Deuterium hollow cathode lamp can eliminate the interference of molecular absorption in low content determination. The detection sensitivity is greatly improved, and the value is less than 0.015 μg/ml/1%.

    • High detection sensitivity and low detection limit of hydride generation atomic absorption spectrometry

    The import known-how such as the advanced pneumatic component theory, and high performance hollow cathode lamp guarantees the hydride generation atomic absorption spectrometry performing a high detection sensitivity and low detection limit. For example, the detection sensitivity of Arsenic element is better than 0.08 ng/ml/1%. The instrument precision is also greatly improved.

    • Convenient software operation system provides reliable data processing result

    The data processing system of AA-1800H is an application of new data processing achievement in the field of atomic absorption spectrometry. It provides reliable data processing result. Meanwhile, the special designed operation software system is advanced and convenient.

    • A partly substitution of graphite furnace atomic spectrometry

    The atomic absorption spectrometry together with on-line enrichment by the pneumatic flow injection system designed by ourselves can determine some elements and obtain a high sensitivity, that means it is a partly substitution of graphite furnace atomic spectrometry for certain elements. Thus, it not only reduces the testing cost, but also improves the instrument utilization.

    • Special designed double-loop power supply for the high performance hollow cathode lamp

    AA-1800H uses special designed double-loop power supply for the high performance hollow cathode lamp, which is convenient for lamp adjusting. It not only improves the lamp energy of some element, but also improves the detection sensitivity to several times. And the performance indexes of the instrument such as stability and detection sensitivity are greatly improved.

    • Unique micro-volume sampler with constant current pulse

    A unique micro-volume sampler with constant current pulse that designed based on the pneumatic component theory is optional to equip with flame atomic absorption spectrometry. The sample volume can be reduced to 0.1 ml, however, there is few influence on the detection sensitivity. And a relative standard deviation about of 1% can be obtained. Thus, it is very significant to medicine and health care industry.

    • Innovative detection system

    Innovative atomic absorption detection system guarantees the instrument having an excellent stability. For a non-zeeman atomic absorption spectrometer, the detection precision of 0.0001A makes it to be unique.

    • USB communication port

    The instrument is controlled by the USB port of computer, which is an advanced communication method. User can choose the computer as required, and that is also available for other laboratory use. However, to avoid viruses, please don’t use this computer for internet surfing.


    1.3 Instrument Specifications

    The instrument specifications are described in the following table:

    ItemsSpecifications
    Monochromator:
    Wavelength Rage:190 nm ~900 nm
    Wavelength Accuracy:≤0.15 nm
    Grating:1800 lines/mm
    Optical System:C-T
    Blazed Wavelength:250 nm
    Focal Length:280 nm
    Reciprocal Linear Dispersion:2 nm/mm
    Bandwidth:1 mm / 0.2 mm / 0.05 mm, selectable
    Detection Sensitivity:
    FAAS:Cu: ≤0.05 μg/ml
    GFAAS:Cd: ≤1 pg, Cu: ≤80 pg
    Detection Limit:
    FAAS:Cu: ≤0.008 μg/ml
    GFAAS:
    Measurement Repeatability(RSD):
    FAAS:Cu: ≤1%
    GFAAS:Cd: ≤5%, Cu: ≤4%
    Stability (Baseline Drift):≤ 0.005 A/30min
    Detection System:
    Photomultiplier (MPT):R928 / R955
    Negative High Voltage:150 V ~ 800 V
    Gain:×1, ×2, ×4
    Light Source:
    Lamps:HCL, HPHCL, Dz
    Lamp Position:No. 1 ~ No. 4: HCL
    No. 5 , No. 6: HPHCL
    Independent holder: Dz
    Lamp Current:HCL: 0.5 mA ~ 9.9 mA

    HPHCL: 0.5 mA ~ 9.9 mA (main current),

    0.5 mA ~ 9.9 mA (auxiliary current)

    Dz: 0.5 mA ~ 19.9 mA
    Flame atomization System:
    Nebulizer:Glass nebulizer with metal sheath designed by Mr. Wu
    Burner:100 mm Steel of Titanium alloy
    Flame Ignitor:Electronic pulse ignition
    Gas Flow Path:Dual-channel designed, automatic security device with fuel gas flameout system


    Items
    Specifications
    Graphite furnace atomization System:
    Temperature control range:Room temperature ~ 3000℃
    Programmed temperature control:Up to 20 stages, ramp and step heating
    Drying stage:Up to 8 stages, each 4 stages for ramp and step heating, each stage 0~99 s duration time
    Ashing stage:Up to 8 stages, each 4 stages for ramp and step heating, each stage 0~99 s duration time
    Atomization stage:Ramp and step heating, 0~20 s duration time
    Clear stage:Ramp and step heating, 0~20 s duration time
    Heating mode:High power heating, and optically controlled high power heating with the temperature range of 1500℃~3000℃, with graphite tube temperature self calibration function
    Temperature accuracy:≤1%
    Heating rate:≥2000 ℃/s
    Security arrangement:Cooling water flow: ≤0.75 L/min (Cooling water supply: ≥0.75 L/min)
    Alarm, and automatically stop heating program when following situation occurs: argon pressure <0.3 MPa, or cooling water temperature 60℃
    Heating program is not allowed when bad contact of graphite tube occurs
    Over current protection
    With the graphite tube usage recording function to remind users to replace the graphite tube when it reaching its service life
    Gas control:Internal gas: 0~300 ml/min, with the internal of 20 ml/min
    External gas: 0, or 1.5 L/min (The external gas is supplied with certain flow of during the four heating stages of drying, ashing, atomization and clear, and there are three kinds of cooling times for chosen, 15 s, 30 s, 45 s. Besides, the external gas is shut off)
    Graphite tube type:Ordinary, pyrogenic and platform graphite tubes
    Graphite tube fixing:Pneumatic switch controlled by computer, stable and safe, with good contact.
    Signal Processing:
    Signal Output:Total absorbance, net absorbance, background absorbance
    Calculation methods:Average, peak height, peak area
    Readings:Absorbance: 0.001~2.000, 0.0001~2.0000, Concentration:0.001~9999
    Calibration methods:4 fitting methods, each curve up to 10 points
    Statistics:SD, RSD, precision
    Background correction methods:D lamp background elimination, self-absorption background deduction
    Dimensions:
    Main Structure:988 mm× 412 mm× 440 mm (L×W×H)
    Power Supply of Graphite Furnace:430 mm× 412 mm× 400 mm(L×W×H)
    Auto-sampler:306 mm× 278 mm× 440 mm(L×W×H)
    Quality AA1800H Six Lamp Atomic Absorption Spectrophotometer Automatic Switching for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Macylab Instruments Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Atomic Absorption Spectrometer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0