| 10.4" TFT LCD screen | High precision flowmeter | Breathing circuit |
Displays the Ventilation parame ters, Alarm information and Oscillogram. | instantly know the fresh gas flow to your patient. | Integrated breathing circuit design, ensure easy operating and keep tidy |
![]() | ![]() | ![]() |
Bellow, APL valve | Vaporizer | Pressure gauge |
Integrated bellow 0mL-1500mL. Suitable for all range patients. Automatic decompression to ensure safety. | Accurately delivers a calibrated flflow, Halothane, Enflflurane, Isoflflurane, Sevoflflurane for choice. Suitable for low flflow anesthesia, save cost. | Real time pressure. |
![]() ![]() | Optional Part 1 | Optional Part 2 |
| Vital sign monitor and anesthetic gas monitor. | ETCO2 module and Anesthesia Gas Scavenging System (AGSS). |
| Ventilation mode |
IPPV, V-A/C, P-A/C, V-SIMV, P-SIMV, PCV-PC, PCV-VG, PSV, SIGH,
MANUAL |
| Ventilator parameter range | |
| Flowmeter | O2 (0 ~ 10 L/min) N2O (0 ~ 10 L/min) or AIR (0 ~ 10 L/min) |
| Rapid oxygen supply | 25 L/min - 75 L/min |
| Tidal volume | 0, 20 mL ~ 1500 mL |
| Frequence(Freq) | 1 /min - 100 /min |
| I:E | 4:1 - 1:8 |
| PEEP | 0 cmH2O - 30 cmH2O |
| Pressure triggering sensitivity (PTr) | -20 cmH2O - 0 cmH2O (Based on PEEP) |
| Flow trigger sensitivity (FTr) | 0.5 L/min - 30 L/min |
Pressure control (PC) | 5 cmH2O ~ 70 cmH2O |
| SIGH | 0 (off) 1/100 - 5/100 |
| Apnea ventilation | OFF, 5s - 60s |
| Pressure limit | 10 cmH2O - 100 cmH2O |
| Alarm and protection | |
| The AC power failure alarm | Power failure or no connection |
| Internal battery backup low voltage alarm | < 10.2 ± 0.3 V |
| No tidal volume | ≤ 5 mL within 6 s |
| High oxygen concentration alarm | 19 % - 100 % |
| Low oxygen concentration alarm | 18 % - 99 % |
| High airway pressure alarm | 2 cmH2O - 100 cmH2O |
| Low airway pressure alarm | 0 cmH2O - 20 cmH2O |
| High minute volume alarm | Adult (5 L/min ~ 20 L/min) |
| Low minute volume alarm | Paed (1 L/min ~ 15 L/min, 0 ~ 10 L/min) |
| Continuous pressure alarm | (PEEP+1.5 kPa) over 16 s |
| Suffocation warning | 5 s - 60 s no spontaneous ventilation |
| The maximum limited pressure | ≤ 12.5 kPa |
| Fan error | Show on screen |
| Oxygen deficit | Show on screen |
| Monitoring parameter | |
| Frequence(Freq) | 0 /min - 100 /min |
| Tidal volume (Vt) | 0 mL - 2000 mL |
| MV | 0 L/min - 100 L/min |
| Oxygen concentration | 15 % - 100 % |
| Working condition | |
| Gas source | O2, N2O, AIR |
| Pressure | 280 kPa ~ 600 kPa |
| Voltage | 100 ~ 240 V |
| Power frequency | 50/60 Hz |
Input power | 80 VA |
| Oscillogram |
| P-T (pressure - time) |
| F-T (flow - time) |
| P-V loop (pressure - volume loop) |
ETCO2-T (ETCO2-time) |
| P-V loop (pressure-volume loop) |
| P-F loop (pressure-flflow loop) |
| F-V loop (flflow-volume loop) |
| Wooden case packing size |
| Wooden case packing size : L 920* W 970* H 1380 mm |
| G.W. :155 KG N.W. :87.5 KG CBM :1.23 m³ |




|