Sign In | Join Free | My burrillandco.com
Home > Pumps >

Magnetic Assisted Electrical Contact Pressure Gauge Manometer For Filter Press YXC100

    Buy cheap Magnetic Assisted Electrical Contact Pressure Gauge Manometer For Filter Press YXC100 from wholesalers
     
    Buy cheap Magnetic Assisted Electrical Contact Pressure Gauge Manometer For Filter Press YXC100 from wholesalers
    • Buy cheap Magnetic Assisted Electrical Contact Pressure Gauge Manometer For Filter Press YXC100 from wholesalers

    Magnetic Assisted Electrical Contact Pressure Gauge Manometer For Filter Press YXC100

    Ask Lasest Price
    Brand Name : Yuwei
    Model Number : YWLB
    Certification : CE, IOS
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union, MoneyGram, D/P, D/A
    Supply Ability : 100000pcs per month
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Magnetic Assisted Electrical Contact Pressure Gauge Manometer For Filter Press YXC100

    Magnetic-Assisted Electric Contact Pressure Gauge YXC100, Special Pressure Gauge For Filter Press



    1. In order to ensure that the elastic element of the pressure gauge can work reliably within the safe range of elastic deformation, the selection of the pressure gauge range should not only be based on the size of the measured pressure, but also consider the speed of the measured pressure change. enough room. When using a pressure gauge to measure stable pressure, the maximum working pressure should not exceed 2/3 of the range;
    2. Use a pressure gauge to measure the pulsating pressure, and the maximum working pressure should not exceed 1/2 of the range;
    3. When using a pressure gauge to measure high pressure, the maximum working pressure should not exceed 3/5 of the range. In order to ensure the measurement accuracy, the minimum working pressure should not be lower than 1/3 of the range. According to this principle, after calculating a value according to the measured maximum pressure, select a measurement range slightly larger than this value from the product catalog of the pressure gauge.
    4. It should be selected according to the working pressure of the boiler. The limit value of the range scale should be 1.5 to 3.0 times the working pressure, preferably 2 times. In industrial boilers, the actual situation is that the actual operating pressure of the boiler is always lower than the rated pressure on the nameplate, both industrial steam boilers and hot water heating boilers. For example, for a 4t/h steam boiler, the rated pressure is 1MPa. If the manufacturer is equipped with a pressure gauge according to 1.5 times, it should be equipped with a 1.6MPa range pressure gauge. If the user is required by the production process, the actual operation can meet the process requirements under the pressure of 0.5MPa. At this time, when the range is run, the pointer of the pressure gauge points to a position less than one-third of the range, and the angle that the pointer rotates is very high. Small. That is, the range of the pressure gauge selected is too large.
    The same is true for hot water boilers. For example, the rated pressure of the heating boiler is 0.7MPa, and the pressure gauge should be 1MPa or 1.6MPa. If the pressure gauge is equipped with 1MPa, it is afraid that the pressure gauge will be overloaded during the hydraulic test, so it is equipped with a range of 1MPa or 1.6MPa. 1.6MPa pressure gauge. In actual operation, as long as 0.2MPa can meet the heating requirements, and the pointer of the pressure gauge points to one-eighth of the range, it is difficult to make people believe in the accuracy and sensitivity of the pressure gauge.
    5. In order to solve the above problems, two kinds of pressure gauges should be used, that is, in the hydraulic test, the pressure gauge equipped by the boiler factory according to the rated pressure should be used;
    6. Equipped with a pressure gauge according to 2 times the actual working pressure during daily operation. If the working pressure is 0.2MPa, a pressure gauge with a range of 0.4MPa should be used. In this way, the pointer is in the middle of the dial, vertically upward. The seat pressure of the safety valve is also adjusted according to the working pressure, and the pressure gauge still has enough margin to cope with the overpressure indication.


    Product modelYN-100B
    Connection SpecificationsM20*1.5 (default)
    Accuracy class1.0/1.6
    Nominal diameter100 / 150mm
    Shell material304 stainless steel
    Custom processing31 6L or other materials can be customized

    Quality Magnetic Assisted Electrical Contact Pressure Gauge Manometer For Filter Press YXC100 for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: YuZhou YuWei Filter Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Filter Press Parts products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0