Full-Scale Overload Protection Digital Clamp Multimeter Working Temperature 18°C~28°C
GENERAL SPEClIFICATIONS
TECHNICAL SPECIFICATIONS
Measuring range & accuracy
(Accuracy guaranteed at 23℃C±5℃C, humidity <75%)
Note: When measuring Sine waves with the true RMS method the meter may display a reading between 1-50A. This is normal and does not affect the accuracy of the meter.
AC Current
| Range | Accuracy | Resolution | 
| 60A | ±(2.5% rdg + 8 digits) | 0.01A | 
| 600A | 0.1A | 
Max. input current: 600AAC.
Frequency range: 50Hz.
DC Current
| Range | Accuracy | Resolution | 
| 60A | ±(2.0% rdg + 8 digits) | 0.01A | 
| 600A | 0.1A | 
Max. input current: 600AAC.
INRUSH Current
| Range | Accuracy | Resolution | 
| 60A | ±(5.0% rdg + 60 digits) | 0.01A | 
| 600A | 1A | 
Inrush measurement time: 100ms.
Amperage range: 20 ~ 600A.
Frequency range: 40 ~ 400Hz.
DC Voltage
| Range | Accuracy | Resolution | 
| 600mV | ±(0.8% rdg + 5 digits) | 0.1 mV | 
| 6V | 0.001V | |
| 60V | 0.01V | |
| 600V | ±(1.0% rdg + 5 digits) | 0.1V | 
Input impedance: 10MQ.
Max. input voltage: 600V AC (RMS) or 600V DC.
Frequency range: 40 ~ 1000Hz
Note:
In the low voltage range, with the test leads is not connected to the circuit under test, the Meter may have a fluctuating reading, this is normal, this it is caused by high sensitivity of the Meter, it does not affect the actual measurement results.
                                 
                             |