Sign In | Join Free | My burrillandco.com
Home > Other Chemical Reagents >

ISO 13485 High Stability Antibody Rapid Test Kit For Any Scene

    Buy cheap ISO 13485 High Stability Antibody Rapid Test Kit For Any Scene from wholesalers
     
    Buy cheap ISO 13485 High Stability Antibody Rapid Test Kit For Any Scene from wholesalers
    • Buy cheap ISO 13485 High Stability Antibody Rapid Test Kit For Any Scene from wholesalers
    • Buy cheap ISO 13485 High Stability Antibody Rapid Test Kit For Any Scene from wholesalers

    ISO 13485 High Stability Antibody Rapid Test Kit For Any Scene

    Ask Lasest Price
    Brand Name : LABNOVATION
    Model Number : LX-401201
    Certification : ISO13485, ISO9001, CE
    Price : US$0.7-1/Piece
    Payment Terms : D/A, D/P, T/T
    Supply Ability : 500000/Day
    Delivery Time : 5-7 work day
    • Product Details
    • Company Profile

    ISO 13485 High Stability Antibody Rapid Test Kit For Any Scene

    Rapid Antibody Test Kit SARS-CoV-2 IgG/IgM Antibody Rapid Test Kit 20 Tests For Professional Use Antibody Rapid Test Kit


    Intended Use
    COVID-19 IgG/IgM Antibody Rapid Test Kit is a rapid test intended for the qualitative detection of the IgM and IgG antibodies to SARS-CoV-2 in human serum, plasma or whole blood sample from patients suspected of COVID-19 infection. The test Kit for professional use only. It is an aid in the diagnosis of the patients with suspected SARS-CoV-2 infection in conjunction with clinical presentation and results of other laboratory tests. But to be attention the test Results from this test kit should not be used as the sole basis for diagnosis. The test provides preliminary test results.
    Specification

    NameSARS-CoV-2 IgG/IgM Antibody Rapid Test Kit
    NumberLX-401201
    Sample TypeSerum/Plasma/Whole Blood
    Products Shelf Life24 Months
    Test Speed<15 minutes
    Sample Volume1 Drop(20ul)
    Sample Typeserum / plasma / whole blood
    Package20 Tests/Box
    Storage Condition2℃-30℃
    Sensitivity>90%
    Specificity>90%
    Total Accuracy>90%


    Main Components

    • 20 Test Cassettes
    • 20 Disposable Pipettes
    • 1 Sample Buffer
    • 1 Instruction Manual

    Product Feature

    • Responsive: High accyracy and stability
    • Quick Check: Easy to use in sample step, 15 minutes out of results
    • Clear results: The detection board is divided into two lines, the result is clear and easy tp read


    Advantage

    • Get result within 10-15 minutes.
    • High accuracy
    • Easy to operate, Suitable for any scene, no professional, no tedious operation
    • Facilitates patient treatment decisions quickly
    • Little specimens is enough

    SAMPLE REQUIREMENT

    • The reagent can be used for the serum, plasma and whole blood samples.
    • A serum / plasma / whole blood sample must be collected in a clean and dry container. EDTA, sodium citrate, heparin can be used as anticoagulants in plasma / whole blood samples. Detect immediately after collecting blood.

    Use Step

    For Serum/Plasma

    1. Remove the test device from the sealed pouch, place it on a clean and level surface with the sample well up.

    2. Add serum or plasma (10µl) vertically into the sample well .

    3. Add two (2) drops (80-100µl) of sample buffer into the sample well .

    4. Observe the test results immediately within 15~20 minutes, the result is invalid over 20 minutes.

    For Whole Blood

    1. Remove the test cassette from the sealed pouch, place it on a clean and level surface with the sample well up.

    2. Add whole blood (20µl) vertically into the sample well .

    3. Add two (2) drops (80-100µl) of sample buffer into the sample well .

    4. Observe the test results immediately within 15~20 minutes, the result is invalid over 20 minutes.


    Interpretation of result

    • POSITIVE: Two or three distinct red lines appear. One line should be in the control region (C) and the other line would be in the test region (IgG line, IgM line or both).
    • NEGATIVE: One red line appears in the control region(C). No red or pink line appears in the test region (IgG line, IgM line).
    • INVALID: No red lines appear or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.


    FAQ

    • How about the MOQ?

    MOQ is more than 10000 pcs, but our sales team will advise you how much to order based on the products you need, national market conditions, international logistics costs and other factors

    • Which certificate you have?

    CE, ISO13485

    • Do you manufacturer or trading company?

    We are factory, all product we supply is R&D and produce by ourself.

    Quality ISO 13485 High Stability Antibody Rapid Test Kit For Any Scene for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Labnovation Technologies, Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Antibody Rapid Test Kit products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0