Sign In | Join Free | My burrillandco.com
Home > Refrigeration & Heat Exchange Equipment >

Non Contact Measurement Ultrasonic Sensor PVDF Low Power Consumption KUS600 Series

    Buy cheap Non Contact Measurement Ultrasonic Sensor PVDF Low Power Consumption KUS600 Series from wholesalers
     
    Buy cheap Non Contact Measurement Ultrasonic Sensor PVDF Low Power Consumption KUS600 Series from wholesalers
    • Buy cheap Non Contact Measurement Ultrasonic Sensor PVDF Low Power Consumption KUS600 Series from wholesalers
    • Buy cheap Non Contact Measurement Ultrasonic Sensor PVDF Low Power Consumption KUS600 Series from wholesalers
    • Buy cheap Non Contact Measurement Ultrasonic Sensor PVDF Low Power Consumption KUS600 Series from wholesalers
    • Buy cheap Non Contact Measurement Ultrasonic Sensor PVDF Low Power Consumption KUS600 Series from wholesalers

    Non Contact Measurement Ultrasonic Sensor PVDF Low Power Consumption KUS600 Series

    Ask Lasest Price
    Brand Name : KACISE
    Model Number : KUS600
    Price : Negotiable
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    Certification : CE
    • Product Details
    • Company Profile

    Non Contact Measurement Ultrasonic Sensor PVDF Low Power Consumption KUS600 Series

    KUS600 Series Ultrasonic Sensor PVDF Non-contact measurement Low power consumption


    Features
    Non-contact measurement
    PVDF casing for corrosion environment
    Low power consumption solution
    Various output options, wide voltage power supply
    KUS600 low-power ultrasonic liquid level gauge is a real low-power ultrasonic sensor with low operating current, the stable time is short and the stability is good. We use nearly new ICs, usually with very low power consumption.The circuit in the sensor consists of three parts, the basic circuit of the transmitting circuit, the receiving circuit and the single-chip microcomputer. The single-chip microcomputer realizes power consumption management by enabling the work of various parts of the control circuit, and then controls power consumption.When the microcontroller itself is not working, it enters sleep mode to further reduce power consumption.
    Dimension
    Unit in the diagram is mm.
    Parameter
    Range

    0.6m-5m, low-power product supports wide voltage input, this range is for 3.3V power supply (6m range customizable)

    Unusable area0 ...0.6m
    Power supply3.3V-24V
    Power consumptionless than 0.3mA when sleep, less than 20mA when emitting, less than 5mA than when measurement
    Output signal0-5V /4-20mA/NPN/PNP/RS485
    Electrical connection5-core cable (analog), 6-core cable (switch)
    Ranging resolution1mm
    Measurement accuracy0.5%-1 %F.S.
    Temp. compensationYes
    Working temperature-25…70(233...358K)
    Storage temperature-40…85(233...358K)
    Protection classIP66
    Casing MaterialPVDF

    Description of Sensor Functions
    Adjusting the analogue output.
    The analogue output can be programed as the user want. Such as working at switch output or working at liner output all the parameters can be set by the RS485 interface. There are 8 types of output functions can be programed. All the setting routine as follows, step 1 set one pointed distance by the RS485, step 2 set another pointed distance by the RS485. Step3 set the output type liner or switch, and set the related output options Step4 reboot the sensor. 1. Window mode normally-open and liner mode positive slope output function. 2. Window mode normally-closed and liner mode negative slope output function. 3. Single switching point, normally-open function. 4. Single switching point, normally-closed function. 5. Single switch point with hysteresis gap normally-open function. 6. Single switch point with hysteresis gap normally-closed function. 7. Detection of object presence-normal open function. 8. Detection of object presence-closed open function. Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 minutes after power on. If want to change the switching point, the user can only set the request distance after power restart.
    For the RS485 output type.
    There are 2 kinds of working style, One for auto measure, the sensor will measure the distance or level repeatedly, and the measurement period can be set by the UART. The measure result can be fetched every time. The other style is power save mode when the sensor is sleep, until the sensor received the inquiry command with pre-code. Communication protocol is Modus-RTU. For example the measure result can be read by access the register 0x101 by Modbus protocol. For more information please contact us for the software engineering guide.

    Quality Non Contact Measurement Ultrasonic Sensor PVDF Low Power Consumption KUS600 Series for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Fluid Level Meter products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0