    Ask Lasest Price
    Brand Name : YuanTe
    Model Number : YT-96H
    Certification : CE ISO9001-2015
    Price : Negotiable
    Payment Terms : T/T, Western Union, Credit Card
    Supply Ability : 500PCS/DAY
    Delivery Time : 2-3 days
    • Product Details
    • Company Profile

    Non Explosionproof Type High Precision Ozone Alarm Tester For Safe Clean Room


    Non Explosionproof Type High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room


    Product overview


    YT-96H-WH is designed specifically for disinfection fields such as pharmaceutical cleanrooms. This is an online monitoring fixed ozone detector. Adopting imported brand electrochemical principle sensors, it has small size, light weight, fast response, accurate detection, reliable operation, and convenient maintenance. 24V DC power supply, standard 4-20mA, RS485 signal and a set of relay signal outputs. Non explosion-proof design, required to be installed in non explosion-proof workplaces.
    Product Advantages
    • All imported electrochemical principle sensors are used
    • Standard three wire 4-20mA analog signal, RS485 signal output
    • Compatible with various control boards, PLC, DCS and other control systems, enabling remote monitoring
    • Standard equipped with a set of relay signals that can control peripheral sound and light alarms, fans, solenoid valves, and other equipment
    • The upper software can achieve setting, calibration, and remote monitoring.​

    Specification


    Detected gas:
    Ozone, etc, according to customer's requirements.
    Detection principle:
    Electrochemical
    Measure range:
    0-1000ppb, 0-1ppm, 0-5ppm, 0-10ppm, 0-20ppm, 0-50ppm, 0-100ppm, etc, according to customer's requirements.
    Resolution:
    1ppb, 0.001ppm, 0.01ppm, 0.1ppm, 1ppm, etc, according to sensor and measure ranges.
    Accuracy:
    ≤±1-2%F.S.
    Response time:
    ≤30 seconds (T90)
    Display:
    Segment LCD
    Shell material:
    Flame Retardant Thermoplastic PS
    Concentration unit:
    ppm, mg/m3
    Alarm mode(Optional):
    Buzzer and light, high and low alarm values can be set by customer.
    Signal output:
    4-20mA, RS485, 1 set of relay output; 1-5VDC(optional)
    Communication and data download:
    With PC software, history data can be downloaded, stored, printed, and analyzed in computer (optional)
    Installation method:
    Wall-mounted
    Power supply:
    24VDC
    Language:
    English
    Humidity:
    0~95%RH (non-condensing)
    Temperature:
    -20℃~+50℃
    Working pressure:
    91~111kpa
    Size:
    80.2*145*62.2mm
    Weight:
    230g (without packaging)


    Pictures




    Package

    Accessories & Configuration list
    Standard accessories
    1. One calibration cap
    2. One fixed gas detector
    3. A certificate of conformity
    4. An instruction manual
    Optional accessoires
    1. Alarm light
    2. 24V DC adapter

    When using an ozone detector, the following points should be noted:


    1. The Industrial Hygiene Standard formulated by the Ministry of Health in 1979 stipulates a safety standard of 0.15 ppm for ozone.
    2. According to American standards, personnel can work continuously for 8 hours at a concentration of 0.1ppm. (Ozone concentration in general forest areas can reach 0.1ppm)
    3. According to the International Ozone Association, professional indoor applications of ozone are allowed to work for 10 hours at a concentration of 0.1 ppm.
    4. The concentration that causes certain reactions in personnel is 0.5-1ppm, and the allowable exposure time is 1.5 hours. Over time, workers may feel discomfort such as dry mouth.
    5. Concentrations of 1-4ppm can cause coughing, with an allowable exposure time of 1 hour.
    6. Concentrations of 4-10ppm can cause strong coughing, with an allowable exposure time of 20 minutes.
    7. The half-life of ozone is 20-50 minutes, and the final decomposition product is oxygen, so it will not cause residual pollution to food.

    Quality Non Explosionproof Type High Precision Ozone Alarm Tester For Safe Clean Room for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shenzhen YuanTe Technology Co., Ltd. (Safegas)
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Single Gas Detector products from this supplier
    Inquiry Cart 0