Sign In | Join Free | My burrillandco.com
Home > Temperature Instruments >

TA-201E Total Organic Carbon Analyser

    Buy cheap TA-201E Total Organic Carbon Analyser from wholesalers
     
    Buy cheap TA-201E Total Organic Carbon Analyser from wholesalers
    • Buy cheap TA-201E Total Organic Carbon Analyser from wholesalers

    TA-201E Total Organic Carbon Analyser

    Ask Lasest Price
    Brand Name : HiYi
    Model Number : TA-201E
    Certification : CE
    Price : $100.00--120/set
    Payment Terms : L/C, D/A, D/P, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 10000 set/month
    Delivery Time : 3-7 days
    • Product Details
    • Company Profile

    TA-201E Total Organic Carbon Analyser

    TA-201E Total Organic Carbon Analyser


    OVERVIEW

    TA-201E adopts the high-temperature catalytic combustion oxidation method, the specimen together with the purification gas (high purity oxygen) are introduced into the high-temperature combustion tube and the low-temperature reaction tube respectively, the specimen through the high-temperature combustion tube is catalytically oxidised by the high temperature, and the organic carbon and inorganic carbon therein are converted into carbon dioxide, and the inorganic carbon therein is decomposed into carbon dioxide after the acidification of the specimen through the low-temperature reaction tube; the carbon dioxide produced by both reaction tubes is introduced into the non-dispersive infrared gas detector NDIR in turn through carrier gas transport, and COThe carbon dioxide produced in the two reaction tubes is sequentially introduced into the non-dispersive infrared gas detector (NDIR) through gas transport, and CO₂ is detected.Thus, the total carbon (TC) and inorganic carbon (IC) in the water are measured separately.The difference between TC and IC is the total organic carbon (TOC).That is: TOC = TC - IC




    FEATURES & BENEFITS


    ModelTA-201E
    Measurement range0~1000mg/L (non-dilution state), dilution state can reach 0~30000mg/L
    Repeatability≤ 3%
    Indication error

    TC; ±0.1%F.S or ±5% (the larger one)

    IC; ±0.1%F.S or ±4% (the larger one)

    LinearityR2≥99.9%
    Lower detection limit0.5mg/L
    Analysis time2~4min
    Injection volume10μL~500μL
    External storageU disk
    Power supplyAC 220V±10% 50/60Hz (reliable grounding required)
    Power1000W when the electric furnace is heated
    Ambient temperature0~40℃
    Relative humidity10~85%
    Setting locationIndoor
    Gas sourcehigh-purity oxygen (≥99.999%)
    High purity WaterCarbon dioxide-free water (TOC≤0.5mg/L)
    Acid reagent10% phosphoric acid
    Instrument placementThere must be 20cm of space around for heat dissipation, and no items can be stacked on top
    Combustion temperature680℃~1200℃
    • 1. High-temperature catalytic oxidation can efficiently oxidize difficult-to-digest organic carbon, making the product easy to analyze high-concentration TOC samples;
      2. Rapid analysis (1-4 minutes);
      3. Higher safety, the combustion furnace heating adopts multiple protections, and the overheating protection circuit is independent of the temperature control system. Overheating can automatically cut off the heating to ensure product safety;
      4. Real-time flow monitoring to maintain flow stability and ensure data reliability;
      5. The pipeline can be cleaned and purged in all directions. The internal circuit can be cleaned according to the needs and operating requirements, which greatly reduces the failure rate and instrument maintenance time;
      6. The instrument automatically discharges waste, automatically discharges and feeds acid, and the acid inlet amount is controlled stably;
      7. Less sample and reagent consumption, each measurement requires 0.5μL of high-purity water, 2ml of acid reagent (for IC testing), and about 2000ml of high-purity oxygen (under standard conditions, flow rate 100ml/min, ventilation time 20min.);
      8. The CO₂ detection of the NDIR detector has good linearity and high accuracy. The CO₂ signal is converted into a peak curve, and then the built-in data processor calculates the TOC value (the difference between TC and IC);
      9. The catalytic combustion oxidation method has strong oxidation ability and can oxidize almost all organic matter with stable performance. The 680℃ combustion method is almost below the melting point of all salts, which can extend the life of the catalyst and combustion tube, which is especially important when the measurement object is a water sample containing salt;
      10. The instrument uses a high-resolution 7-inch touch wide screen and adopts an intelligent system for easy operation.

    Quality TA-201E Total Organic Carbon Analyser for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Beijing HiYi Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Lab Equipment And Consumables products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0