Sign In | Join Free | My burrillandco.com
Home > Weighing Scales >

TL2350 Turbidity Meter Kit EPA 0 - 10000 NTU With 1 Inch Sample Cells And Caps

    Buy cheap TL2350 Turbidity Meter Kit EPA 0 - 10000 NTU With 1 Inch Sample Cells And Caps from wholesalers
     
    Buy cheap TL2350 Turbidity Meter Kit EPA 0 - 10000 NTU With 1 Inch Sample Cells And Caps from wholesalers
    • Buy cheap TL2350 Turbidity Meter Kit EPA 0 - 10000 NTU With 1 Inch Sample Cells And Caps from wholesalers

    TL2350 Turbidity Meter Kit EPA 0 - 10000 NTU With 1 Inch Sample Cells And Caps

    Ask Lasest Price
    Brand Name : HiYi
    Model Number : TL2350
    Certification : CE
    Supply Ability : 1000 set/month
    Delivery Time : 3-7 days
    • Product Details
    • Company Profile

    TL2350 Turbidity Meter Kit EPA 0 - 10000 NTU With 1 Inch Sample Cells And Caps

    TL2350 Tungsten Lamp Turbidimeter


    OVERVIEW

    The new TL23 Series laboratory turbidimeters blend trusted technology and improved features to simplify testing in the most demanding wastewater and industrial applications.


    FEATURES

    • Trusted measurement for high turbidity applications; simplified.
    • Large full color touch screen display and intuitive user interface accelerate setup, calibration and measurement.
    • Ensures stable readings and accurate analysis.
    • With a USB port for easy data export, sample identification for traceability.

    SPECIFICATION

    AccuracyRatio on: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU ±10 % of reading from 4000 - 10000 NTU

    Ratio off: ±2% of reading plus 0.01 NTU from 0 - 40 NTU
    Accuracy 3Absorbance: ±0.01 Abs from 0 - 0.5 Abs at 455 nm, ±2% Abs from 0.5 - 1 Abs at 455 nm

    Transmittance: 2% T from 10 - 100% T at 455 nm
    Air PurgeDry nitrogen or instrument grade air (ANSI MC 11.1, 1975)
    0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) max
    Hose barb connection for 1/8-inch tubing
    CertificationsCE, KC, RCM
    CommunicationUSB
    ComplianceEPA
    Data Logging2000 total logs, includes reading log, verification log and calibration log
    Dimensions (H x W x D)153 mm x 395 mm x 305 mm
    Display17.8 mm (7 in.) color touch screen
    Interface2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner
    Light SourceTungsten filament lamp
    Measurement MethodNephelometric
    ModelTL2350 EPA
    Operating Temperature Range0 - 40 °C
    Power Requirements (Amps)3.4 A
    Power Requirements (Hz)50/60 Hz
    Power Requirements (Voltage)100 - 240 VAC
    Range0 - 10000 NTU
    RangeNTU (Ratio on): 0 - 10000 auto decimal

    NTU (Ratio off): 0 - 40

    EBC (Ratio on): 0 - 2450 auto decimal

    EBC (Ratio off): 0 - 9.8

    Absorbance (auto range): 0 - 1.0

    Transmittance (%): 1.0 - 100

    Degree (mg /L): 1 - 100
    Reading ModesSingle, continuous, Rapidly Settling Turbidity™, signal averaging on or off, ratio on or off
    RegulatoryMeets EPA Method 180.1
    Repeatability±1% of reading or 0.01 NTU, whichever is greater (under reference conditions)
    Response TimeSignal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average)
    Sample Cell CompatibilityRound cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps

    Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used.
    Sample Requirements25 mm sample cell: 20 mL minimum
    0 to 70 °C (32 to 158 °F)
    Source LampTungsten Lamp
    Stabilization TimeRatio on: 30 minutes after start-up

    Ratio off: 60 minutes after start-up
    Storage Conditions-20 to 60 °C
    UnitsNTU, EBC, Abs (absorbance), %T (% transmittance) and mg/L
    Weight3.0 kg
    What's included?TL2350 Turbidimeter, silicone oil, oiling cloth, USEPA filter assembly, 1-inch sample cells (30 mL) with caps (6x), Gelex secondary turbidity standardization kit, Stablcal calibration kit, power supply, power cord, dust cover


    Quality TL2350 Turbidity Meter Kit EPA 0 - 10000 NTU With 1 Inch Sample Cells And Caps for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Beijing HiYi Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Water Quality Analyzer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0