Sign In | Join Free | My burrillandco.com
Home > Other Chemical Reagents >

Spectinomycin Rapid Test Strip In Dairy Milk Products

    Buy cheap Spectinomycin Rapid Test Strip In Dairy Milk Products from wholesalers
     
    Buy cheap Spectinomycin Rapid Test Strip In Dairy Milk Products from wholesalers
    • Buy cheap Spectinomycin Rapid Test Strip In Dairy Milk Products from wholesalers

    Spectinomycin Rapid Test Strip In Dairy Milk Products

    Ask Lasest Price
    Brand Name : HiYi
    Model Number : Spectinomycin
    Certification : CE
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Delivery Time : 15 work days
    • Product Details
    • Company Profile

    Spectinomycin Rapid Test Strip In Dairy Milk Products

    Spectinomycin rapid test strip


    OVERVIEW

    Brief:

    The Spectinomycin rapid test strip is used for testing Spectinomycin residue in milk qualitatively. The whole test only need 8min, east to operate with high sensitivity.

    Detection limit: 5~8ng/ml (ppb)


    Principle:

    The Spectinomycin rapid test strip is based on competitive inhibition immuno-chromatographic principle. In the flow process, Spectinomycin in the sample combined with Spectinomycin specific colloidal gold-labeled monoclonal antibody, Inhibit the combination between antibody and Spectinomycin-BSA conjugate on Test line of NC membrane, lead to the color change of Test line. When the sample has no Spectinomycin residue or concentration lower than detection limit, T line is darker then C line; when the concentration is equal to or higher than detection limit, T line is lighter than C line or T line has no color or T line has same color with C line. No matter whether there is Spectinomycin residue in sample, C line will appear, it means the test is valid.

    FEATURES & BENEFITS

    Operation procedures:

    1 Read the instruction carefully before use. Return test strips and sample into room temperature.

    2 Take bottles needed from the kit package, take out required microwells, making proper marks, Please use it in 1 hour. Seal the cap of the bottles, avoid moisture.

    3 Use Micro-pipette to take 200ul of the samples into the microwells, then repeatedly absorb for 5 times, mix the sample with the reagent in the microwells completely until no solid judged by eyes (this is a very important step).

    4 Incubate at 40±2℃for 3 min. Then insert the strip into micro-well, put the end with MAX down into the liquid.

    5 Insert the strip into the liquid for 5min, then read the result.


    Test Result Interpretation:

    Color depth comparison of T line and C lineResult judgmentResult analysis
    T line >C lineNegativeSpectinomycinresidue is lower than detection limit in sample
    T line =C lineWeak positiveSpectinomycin residue is equal to detection limit in sample
    T line <C line or T line is invisiblePositiveSpectinomycin residue is higher than detection limit in sample
    C line is invisibleInvalid

    The test strip is invalid, test again


    Results picture show:


    Precautions:

    1) The test strip is used for once at room temperature, do not use test strip out of date.

    2) Cover the bottle immediately after taking out the reagent. If can’t use 8 micro-wells for one time, cover the micro-wells immediately and put back to the bottle, store in seal.

    3) Do not touch the white membrane surface in the middle of test strip, avoid sunlight and fan blowing directly.

    4) Milk samples should be fresh and no polluted, for sample store in cold and frozen should return to room temperature before testing.

    5) Use the test strips testing again for positive results.

    6) Please contact the supplier for any questions.

    7) The result is for reference. To confirm, please refer national standard method.


    Specificity:

    This product has no cross-reaction with Quinolones, Sulfonamides and Chloramphenicol etc.

    SPECIFICATIONS

    Storage and expiry date:

    Storage: Store at 2-8 ℃ in sealed, dry, and dark place,no frozen.
    Expiry date: 12 months; date of production is on box.


    Detection limit: 5~8ng/ml (ppb)



    Quality Spectinomycin Rapid Test Strip In Dairy Milk Products for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Beijing HiYi Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Lab Equipment And Consumables products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0