Sign In | Join Free | My burrillandco.com
Home > Other Electrical Equipment >

Single Phase AC Voltage Calibrator 45Hz - 70Hz Precision Calibrator TD1600

    Buy cheap Single Phase AC Voltage Calibrator 45Hz - 70Hz Precision Calibrator TD1600 from wholesalers
     
    Buy cheap Single Phase AC Voltage Calibrator 45Hz - 70Hz Precision Calibrator TD1600 from wholesalers
    • Buy cheap Single Phase AC Voltage Calibrator 45Hz - 70Hz Precision Calibrator TD1600 from wholesalers

    Single Phase AC Voltage Calibrator 45Hz - 70Hz Precision Calibrator TD1600

    Ask Lasest Price
    Model Number : TD1600
    Brand Name : TUNKIA
    Price : negotiation
    Payment Terms : negotiation
    • Product Details
    • Company Profile

    Single Phase AC Voltage Calibrator 45Hz - 70Hz Precision Calibrator TD1600

    TD1600 Precision AC Calibrator

    Introduction

    • TD1600, a single-phase AC calibrator with wide range, high precision and multifunction.

    • The apparatus can output high accuracy AC voltage, current and power, and the optional accuracy are 0.05% and 0.02%. Applied to calibrate various AC electrical measuring instruments.

    Features

    • AC Electrical Parameter Output: Voltage is up to 1100 V, current is up to 110 A.

    • Frequency and Phase Adjustment: Frequency: 45 Hz ~ 70 Hz.

    • AC Power Output: Measure the active power, reactive power, apparent power and power factor.

    • Value Output Mode: Standard source and output source modes, easy to calibrate both digital meters and analogue meters.

    • Value Adjustment Method: Fixed-point, rotary encoder, step and potentiometer (option).

    • Output Switch: The output can be turned on/off arbitrarily by one-touch operation.

    • Automatical Error Calculation: Set the measured values of the checked meter, and adjust the value output to automatically calculate the errors of the checked meter.

    • Excellent Human-computer Interaction: Large LCD touch screen display, touch and button operation modes, easy for users to measure manually.

    • Harmonic (Option): Load 2nd to 31st harmonics with variable amplitude and phase for impact test.

    • Proprietary Software (Option): Support the calibration of the checked meters by semi-automatic or full-automatic, data management and report export.


    Specification


    AC Voltage Output

    RangeStability (%/min)

    Accuracy (k = 2)

    (ppm*RD + ppm*RG)

    Max. Load Current

    (mA)

    0.05%0.02%0.05%0.02%
    1 V0.010.005300 + 200120 + 80500
    3 V0.010.005300 + 200120 + 80500
    10 V0.010.005300 + 200120 + 80500
    30 V0.010.005300 + 200120 + 80500
    60 V0.010.005300 + 200120 + 80800
    100 V0.010.005300 + 200120 + 80500
    150 V0.010.005300 + 200120 + 80400
    200 V0.010.005300 + 200120 + 80250
    300 V0.010.005300 + 200120 + 80150
    400 V0.010.005300 + 200120 + 80100
    600 V0.010.005300 + 200120 + 8080
    750 V0.010.005300 + 200120 + 8060
    1000 V0.010.005300 + 200120 + 8050

    AC Current Output

    RangeStability (%/min)

    Accuracy (k = 2)

    (ppm*RD + ppm*RG)

    Max. Inductive

    Load (V)

    0.05%0.02%0.05%0.02%
    1 mA1 μA0.5 μA300 + 2 μA120 + 1 μA120
    2 mA1 μA0.5 μA300 + 2 μA120 + 1 μA120
    5 mA1 μA0.5 μA300 + 2 μA120 + 1 μA120
    10 mA0.010.005300 + 200120 + 80120
    20 mA0.010.005300 + 200120 + 80120
    50 mA0.010.005300 + 200120 + 80120
    100 mA0.010.005300 + 200120 + 80120
    200 mA0.010.005300 + 200120 + 80120
    500 mA0.010.005300 + 200120 + 80100
    1 A0.010.005300 + 200120 + 8050
    2 A0.010.005300 + 200120 + 8025
    5 A0.010.005300 + 200120 + 8010
    10 A0.010.005300 + 200120 + 805
    20 A0.010.005300 + 200120 + 802.5
    30 A0.010.005300 + 200120 + 802.5
    50 A0.010.005300 + 200120 + 801.5
    100 A0.010.005300 + 200120 + 800.8

    Output Characteristics of Voltage and Current

    • Output Range of Voltage: 100 mV ~ 1100 V

    • Output Range of Current: 0.1 mA/ 20 mA ~ 110 A

    • Range Switching: Automatic or Manual.

    • Resolution: 0.001 %*RG; Display: 6 digits; Distortion: <0.2 %

    • 1 mA,2 mA,5 mA are small range option.


    Frequency, Phase and Harmonic (Option)

    TypeRangeResolutionAccuracy
    Frequency45.000 Hz ~ 70.000 Hz0.001 Hz0.005 Hz
    Phase0.0000 ° ~ 359.9999 °0.005 °0.05 °
    TypeOrderAmplitudeVariable Phase
    Harmonic2nd to 31st0 ~ 25 %0 ~ 359.9 °

    Power Output

    TypeStability (%/min)Accuracy (k = 2) %*FS
    0.05%0.02%0.05%0.02%
    Active Power0.010.0050.050.025
    Reactive Power0.020.010.10.05
    Apparent Power0.020.010.10.05
    Power Factor0.020.010.10.05
    • Output Range of AC Power: Combination of AC voltage range and AC current range.

    • Range of Power Factor: -1.0000…0.0000…+1.0000

    • Active Power (|cosφ| ≥0.5), Reactive Power (|sinφ| ≥0.5)

    Quality Single Phase AC Voltage Calibrator 45Hz - 70Hz Precision Calibrator TD1600 for sale
    Company Info.
    Tunkia Co., Ltd.
    Verified Supplier
    View Contact Details
    Product List
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Tunkia Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Fluke Multifunction Calibrator products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0