Sign In | Join Free | My burrillandco.com
Home > Food & Beverage Machinery >

3051CD3A02A1AH2KDL5M5Q4Q8 Pressure Temperature Transmitter 3051C

    Buy cheap 3051CD3A02A1AH2KDL5M5Q4Q8 Pressure Temperature Transmitter 3051C from wholesalers
     
    Buy cheap 3051CD3A02A1AH2KDL5M5Q4Q8 Pressure Temperature Transmitter 3051C from wholesalers
    • Buy cheap 3051CD3A02A1AH2KDL5M5Q4Q8 Pressure Temperature Transmitter 3051C from wholesalers
    • Buy cheap 3051CD3A02A1AH2KDL5M5Q4Q8 Pressure Temperature Transmitter 3051C from wholesalers

    3051CD3A02A1AH2KDL5M5Q4Q8 Pressure Temperature Transmitter 3051C

    Ask Lasest Price
    Brand Name : ROSEMOUNT
    Model Number : 3051CD3A02A1AH2KDL5M5Q4Q8
    Price : Negotiate
    Payment Terms : T/T,PAYONEER
    Supply Ability : 20EA,6weeks
    Delivery Time : 6 WEEKS
    Certification : Does not supply
    • Product Details
    • Company Profile

    3051CD3A02A1AH2KDL5M5Q4Q8 Pressure Temperature Transmitter 3051C

    3051CD3A02A1AH2KDL5M5Q4Q8 Rosemount 3051C Coplanar Pressure Transmitters


    Rosemount 3051C Coplanar Pressure Transmitters are the industry standard for differential, gage, and absolute pressure measurement. The coplanar platform enables seamless integration with manifolds, flow, and level solutions.

    Capabilities include:

    1) The Loop Integrity Diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitted 4-20mA output signal .

    2) LOI with straightforward menus and built-in configuration buttons .

    3) Safety certification.


    (1) If ordered with Wireless output code X, only available with 316L stainless steel (SST) diaphragm material (code 2), and silicone fill fluid.

    (2) Rosemount 3051CD0 is only available with output code A and X. For output code A, only process flange code 0 (Alternate flange H2, H7, HJ,or HK), isolating diaphragm code 2, O ring code A, and bolting option L4 are available. For output code X, only process flange code 0 (Alternate flange H2), isolating diaphragm code 2, O ring code A, and bolting option L4 are available.

    (3) HART Revision 5 is the default HART output.

    (4) For local addressing and configuration, M4 (LOI) is required.

    (5) Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1),IECEx Intrinsic Safety (option code I7) and EAC Intrinsic Safety (option code IM).


    More options :

    3051TA3A2B21AB4M5E5

    3051TA4A2B21AB4M5E5

    3051TA5A2B21AB4M5E5

    3051TA1A2B21AB4M5I5

    3051TA2A2B21AB4M5I5

    3051TA3A2B21AB4M5I5

    3051TA4A2B21AB4M5I5

    3051TA5A2B21AB4M5I5

    3051GP1A2B21AB4M5

    3051GP2A2B21AB4M5

    3051GP3A2B21AB4M5

    3051GP4A2B21AB4M5


    SGD-02ANY6

    SGD-02AP

    SGD-02AS

    SGD-02BH

    SGD-02BP

    SGD-02BS+SGM-02B312

    SGD-02BS+SGM-02B314

    SGD-04AN

    SGD-04AN+SGM-04A3NT12

    SGD-04AP

    SGD-04APY61

    SGD-04AS

    SGD-04ASY52

    SGD-04ASY53

    SGD-08AH

    SGD-08AN

    SGD-08AP

    SGD-08APY61

    Rosemount 3051C Coplanar Pressure Transmitters Information :

    ModelTransmitter type
    3051CCoplanar pressure transmitter
    Measurement type
    DDifferential
    GGage
    A(1)Absolute
    Pressure range
    Differential (Rosemount 3051CD)Gage (Rosemount 3051CG)Absolute (Rosemount 3051CA)
    1

    –25 to 25 inH2O (–62,16 to 62,16

    mbar)

    –25 to 25 inH2O (–62,16 to

    62,16 mbar)

    0 to 30 psia (0 to 2,06 bar)
    2

    –250 to 250 inH2O (–621,60 to

    621,60 mbar)

    –250 to 250 inH2O (–621,60 to

    621,60 mbar)

    0 to 150 psia (0 to 10,34 bar)
    3

    –1000 to 1000 inH2O (–2,48 to

    2,48 bar)

    –393 to 1000 inH2O (–0,97 to

    2,48 bar)

    0 to 800 psia (0 to 55,15 bar)
    4

    –300 to 300 psi (–20,68 to 20,68

    bar)

    –14.2 to 300 psi (–0,97 to 20,68

    bar)

    0 to 4000 psia (0 to 275,79 bar)
    5

    –2000 to 2000 psi (–137,89 to

    137,89 bar)

    –14.2 to 2000 psi (–0,97 to

    137,89 bar)

    N/A
    0(2)–3 to 3 inH2O (-7,46 to 7,46 mbar)N/AN/A
    Transmitter output
    A(3)4–20 mA with digital signal based on HART® Protocol
    FFOUNDATION™ Fieldbus Protocol
    W(4)PROFIBUS® PA Protocol
    X (5)Wireless (requires wireless options and engineered polymer housing)
    M(6)Low-power, 1–5 Vdc with digital signal based on HART Protocol
    Materials of construction
    Process flange typeFlange materialDrain/vent
    2CoplanarSSTSST
    3(7)CoplanarCast C-276Alloy C-276
    4CoplanarAlloy 400Alloy 400/K-500
    5CoplanarPlated CSSST
    7(7)CoplanarSSTAlloy C-276
    8(7)CoplanarPlated CSAlloy C-276
    0Alternate process connection
    Isolating diaphragm
    2(7)316L SST
    3(7)Alloy C-276
    4(8)Alloy 400
    5(8)Tantalum (available on Rosemount 3051CD and CG, ranges 2–5 only; not available on Rosemount 3051CA)
    6(8)Gold-plated alloy 400 (use in combination with O-ring option code B)
    7(8)Gold-plated 316 SST
    O-ring
    AGlass-filled PTFE
    BGraphite-filled PTFE
    Sensor fill fluid
    1Silicone
    2(8)Inert (differential and gage only)
    Housing materialConduit entry size
    AAluminum½–14 NPT
    BAluminumM20 x 1.5
    EAluminum, ultra low copper½–14 NPT
    FAluminum, ultra low copperM20 x 1.5
    JSST½–14 NPT
    KSSTM20 x 1.5
    P(9)Engineered polymerNo conduit entries
    D(10)Aluminum
    M(10)SST
    Wireless options(11)
    Wireless transmit rate, operating frequency, and protocol
    WA3User Configurable Transmit Rate, 2.4 GHz WirelessHART
    Antenna and SmartPower
    WP5Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)
    Options
    Extended product warranty
    WR33-year limited warranty
    WR55-year limited warranty
    Plantweb control functionality
    A01FOUNDATION Fieldbus control function block suite
    Plantweb diagnostic functionality
    DA0Loop Integrity HART Diagnostic
    D01FOUNDATION Fieldbus Diagnostics Suite
    Alternate flange(12)
    H2Traditional flange, 316 SST, SST drain/vent
    H3(7)Traditional flange, alloy C, alloy C-276 drain/vent
    H4Traditional flange, cast alloy 400, alloy 400/K-500 drain/vent
    H7(7)Traditional flange, 316 SST, alloy C-276 drain/vent
    HJDIN-compliant traditional flange, SST, 7/16-in. (10 mm) adapter/manifold bolting
    FALevel flange, SST, 2-in. (51 mm), ANSI class 150, vertical mount 316 SST drain/vent
    FBLevel flange, SST, 2-in. (51 mm), ANSI Class 300, vertical mount 316 SST drain/vent
    FCLevel flange, SST, 3-in. (76 mm), ANSI Class 150, vertical mount 316 SST drain/vent
    FDLevel flange, SST, 3-in. (76 mm), ANSI Class 300, vertical mount 316 SST drain/vent
    FPDIN level flange, SST, DN 50, PN 40, vertical mount 316 SST drain/vent
    FQDIN level flange, SST, DN 80, PN 40, vertical mount 316 SST drain/vent
    HK(13)DIN compliant traditional flange, SST, .4 in. (10 mm) adapter/manifold bolting 316 SST
    HLDIN compliant traditional flange, SST, .5 in. (12 mm) adapter/manifold bolting 316 SST
    Manifold assembly(14)
    S5Assemble to Rosemount 305 Integral Manifold
    S6Assemble to Rosemount 304 Manifold or Connection System
    Integral mount primary element(13)(14)
    S3Assemble to Rosemount 405 Compact Orifice Plate
    S4(15)Assemble to Rosemount Annubar or Rosemount 1195 Integral Orifice
    Seal assemblies(14)
    S1(16)Assemble to one Rosemount 1199 seal
    S2(17)Assemble to two Rosemount 1199 seals
    Mounting bracket(18)
    B4Coplanar flange bracket, all SST, 2-in. pipe and panel
    B1Traditional flange bracket, CS, 2-in. pipe
    B2Traditional flange bracket, CS, panel
    B3Traditional flange flat bracket, CS, 2-in. (51 mm) pipe
    B7Traditional flange bracket, B1 with SST bolts
    B8Traditional flange bracket, B2 with SST bolts
    B9Traditional flange bracket, B3 with SST bolts
    BATraditional flange bracket, B1, all SST
    BCTraditional flange bracket, B3, all SST
    Product certifications
    E8ATEX Flameproof and Dust Certification
    I1(19)ATEX Intrinsic Safety and Dust
    IAATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocol only
    N1ATEX Type n Certification and Dust
    K8ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)
    E4(20)TIIS Flame-proof
    E5FM Explosion-proof, Dust Ignition-Proof
    I5(21)FM Intrinsically Safe, Nonincendive
    IEFM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocol only
    K5FM Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2
    C6CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
    E6CSA Explosion-proof, Dust Ignition-proof, Division 2
    I6(9)CSA Intrinsic Safety
    K6CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)
    E7IECEx Flameproof, Dust Ignition-proof
    I7IECEx Intrinsic Safety
    N7IECEx Type n Certification
    K7IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
    E2INMETRO Flameproof
    I2INMETRO Intrinsic Safety
    IBINMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
    K2INMETRO Flameproof, Intrinsic Safety
    E3China Flameproof
    I3China Intrinsic Safety
    N3China Type n
    EMTechnical Regulations Customs Union (EAC) Flameproof
    IMTechnical Regulations Customs Union (EAC) Intrinsic Safety
    KMTechnical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety
    KBFM and CSA Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)
    KDFM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
    EP(22)Republic of Korea Flameproof
    IP(23)Republic of Korea Intrinsic Safety
    KP(24)Republic of Korea Flameproof, Intrinsic Safety
    Drinking water approval(25)
    DWNSF drinking water approval
    Shipboard approvals(8)
    SBSAmerican Bureau of Shipping
    SBV(26)Bureau Veritas (BV)
    SDNDet Norske Veritas
    SLL(26)Lloyds Register (LR)
    Custody transfer(27)
    C5Measurement Canada Accuracy Approval (limited availability depending on transmitter type and range; contact an Emerson representative).
    Bolting material
    L4Austenitic 316 SST bolts
    L5ASTM A 193, grade B7M bolts
    L6Alloy K-500 bolts
    Display and interface options
    M4(28)LCD display with LOI
    M5LCD display
    Calibration certificate
    Q4Calibration Certificate
    QG(29)Calibration Certificate and GOST Verification Certificate
    QPCalibration certification and tamper evident seal
    Material traceability certification
    Q8Material Traceability Certification per EN 10204 3.1
    Quality certification for safety (27)
    QSPrior-use certificate of FMEDA data
    QTSafety certified to IEC 61508 with certificate of FMEDA
    Configuration buttons
    D4(27)Analog zero and span
    DZ(30)Digital zero trim
    Transient protection(8) (31)
    T1Transient protection terminal block
    Software configuration(30)
    C1Custom software configuration (For wired, see the Rosemount 3051 Configuration Data Sheet. For wireless, see the Rosemount 3051 Wireless Configuration Data Sheet.)
    Low power output
    C20.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)
    Gage pressure calibration
    C3Gage calibration (Rosemount 3051ca4 only)
    Alarm levels(27)
    C4(32)Analog output levels compliant with NAMUR recommendation NE 43, alarm high
    CN(32)Analog output levels compliant with NAMUR recommendation NE 43, alarm low
    CRCustom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)
    CSCustom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)
    CTRosemount standard low alarm
    Pressure testing
    P1Hydrostatic testing with certificate
    Cleaning process area
    P2Cleaning for special service
    P3(33)Cleaning for < 1 ppm chlorine/fluorine
    Flange adapters (34)
    DF½–14 NPT flange adapter(s)
    Vent/drain valves
    D7Coplanar flange without drain/vent ports
    DCPorts left open - None
    Conduit plug(8)
    DO316 SST conduit plug
    RC¼ RC½ process connection(35)
    D9RC¼ flange with RC½ flange adapter - SST
    Max static line pressure
    P94500 psig (310,26 bar) static pressure limit (Rosemount 3051CD Ranges 2–5 only)
    Ground screw(8)(36)
    V5External ground screw assembly
    Surface finish
    Q16Surface finish certification for sanitary remote seals
    Toolkit total system performance reports
    QZRemote seal system performance calculation report
    Conduit electrical connector(8)
    GEM12, 4-pin, male connector (eurofast®)
    GMA size mini, 4-pin, male connector (minifast®)
    NACE® certificate(37)
    Q15Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials
    Q25Certificate of Compliance to NACE MR0103 for wetted materials
    Cold temperature(38)
    BR5(39)–58 °F (–50 °C) cold temperature operation
    BR6(40)–76 °F (–60 °C) cold temperature operation
    HART revision configuration (requires HART Protocol output code A)(3)
    HR5Configured for HART Revision 5
    HR7Configured for HART Revision 7
    Typical Model Number: 3051CD 2 A 2 2 A 1 A B4


    Good Service in WTL:
    > We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
    > Please send your RFQ to get the latest price.
    > Normally, we will ship the items in 1-2 weeks after receive the payment.
    > We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
    > We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.

    If needed, please contact us for specific prices.


    OUR MAIN BRAND:

    Quality 3051CD3A02A1AH2KDL5M5Q4Q8 Pressure Temperature Transmitter 3051C for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Wisdomlong Technology CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Pressure Temperature Transmitter products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0