| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | ROSEMOUNT |
| Model Number : | 3051L2AA2AD21AADFE5 |
| Price : | Negotiate |
| Payment Terms : | T/T,PAYONEER |
| Supply Ability : | 20EA,6weeks |
| Delivery Time : | 6 WEEKS |
| Certification : | Does not supply |
3051L2AA2AD21AADFE5 Level Transmitter 4–20 mA Rosemount 3051L
Product Information Of : 3051L2AA2AD21AADFE5
| Brand | EMERSON ROSEMOUNT |
| Model | 3051L2AA2AD21AADFE5 |
| SUPPLY | 4–20 mA |
| SIZE | NOS |
| Weight | 5KG |
The Rosemount 3051L Level Transmitter combines the performance and
capabilities of Rosemount 3051 Transmitters with the reliability
and quality of a direct mount seal in one model number. Rosemount
3051L Level Transmitters offer a variety of process connections,
configurations, and fill fluid types to meet a breadth of level
applications. Capabilities of a Rosemount 3051L Level Transmitter
include:
■Quantify and optimize total system performance (option code QZ).
■Tuned-system assembly (option code S1).
■The Loop Integrity Diagnostic continuously monitors the electrical
loop to detect changes that compromise the integrity of the
transmitted 4-20 mA output signal (Option Code DA0).
■LOI with straightforward menus and built-in configuration buttons
(option code M4).
More options :
A20B-8200-0382
A20B-8200-0383
A20B-8200-0384
A20B-8200-0385
A20B-8200-0390
A20B-8200-0391
A20B-8200-0392
A20B-8200-0393
A20B-8200-0395
A20B-8200-0396
SGDH-10AE
SGDH-30AE
SGDP-A3APAY108
SGDS-01A01A
SGD-01AN+SGM-01A3NT14
SGD-01AHY130
SGD-01AS
SGD-01BH
SGD-01BP
SGD-02AH
SGD-02AHY500
SGD-02AN
Rosemount 3051L Level Transmitter Information:
| Model | Transmitter type | |||
| 3051L | Level transmitter | |||
| Pressure range | ||||
| 2 | –250 to 250 in H2O (–621,60 to 621,60 mbar) | ★ | ||
| 3 | –1000 to 1000 in H2O (–2,48 to 2,48 bar) | ★ | ||
| 4 | –300 to 300 psi (–20,68 to 20,68 bar) | ★ | ||
| Transmitter output | ||||
| A(1) | 4–20 mA with digital signal based on HART® Protocol | ★ | ||
| F | FOUNDATION™ Fieldbus Protocol | ★ | ||
| W(2) | PROFIBUS® PA Protocol | ★ | ||
| X(3) | Wireless (requires wireless options and engineered polymer housing) | ★ | ||
| M(4) | Low-power 1–5 Vdc with digital signal based on HART Protocol | |||
| Process connection size, material, extension length (high side) | ||||
| Code | Process connection size | Material | Extension length | |
| G0(5) | 2-in./DN 50/A | 316L SST | Flush mount only | ★ |
| H0 (5) | 2-in./DN 50 | Alloy C-276 | Flush mount only | ★ | |
| J0 | 2-in./DN 50 | Tantalum | Flush mount only | ★ | |
| A0(5) | 3-in./DN 80 | 316L SST | Flush mount | ★ | |
| A2(5) | 3-in./DN 80 | 316L SST | 2-in./50 mm | ★ | |
| A4(5) | 3-in./DN 80 | 316L SST | 4-in./100 mm | ★ | |
| A6(5) | 3-in./DN 80 | 316L SST | 6-in./150 mm | ★ | |
| B0(5) | 4-in./DN 100 | 316L SST | Flush mount | ★ | |
| B2(5) | 4-in./DN 100 | 316L SST | 2-in./50 mm | ★ | |
| B4(5) | 4-in./DN 100 | 316L SST | 4-in./100 mm | ★ | |
| B6(5) | 4-in./DN 100 | 316L SST | 6-in./150 mm | ★ | |
| C0(5) | 3-in./DN 80 | Alloy C-276 | Flush mount | ★ | |
| C2(5) | 3-in./DN 80 | Alloy C-276 | 2-in./50 mm | ★ | |
| C4(5) | 3-in./DN 80 | Alloy C-276 | 4-in./100 mm | ★ | |
| C6(5) | 3-in./DN 80 | Alloy C-276 | 6-in./150 mm | ★ | |
| D0(5) | 4-in./DN 100 | Alloy C-276 | Flush mount | ★ | |
| D2(5) | 4-in./DN 100 | Alloy C-276 | 2-in./50 mm | ★ | |
| D4(5) | 4-in./DN 100 | Alloy C-276 | 4-in./100 mm | ★ | |
| D6(5) | 4-in./DN 100 | Alloy C-276 | 6-in./150 mm | ★ | |
| E0 | 3-in./DN 80 | Tantalum | Flush mount only | ★ | |
| F0 | 4-in./DN 100 | Tantalum | Flush mount only | ★ | |
| Mounting flange size, rating, material (high side) | |||||
| Size | Rating | Material | |||
| M | 2-in. | ANSI/ASME B16.5 Class 150 | CS | ★ | |
| A | 3-in. | ANSI/ASME B16.5 Class 150 | CS | ★ | |
| B | 4-in. | ANSI/ASME B16.5 Class 150 | CS | ★ | |
| N | 2-in. | ANSI/ASME B16.5 Class 300 | CS | ★ | |
| C | 3-in. | ANSI/ASME B16.5 Class 300 | CS | ★ | |
| D | 4-in. | ANSI/ASME B16.5 Class 300 | CS | ★ | |
| P | 2-in. | ANSI/ASME B16.5 Class 600 | CS | ★ | |
| E | 3-in. | ANSI/ASME B16.5 Class 600 | CS | ★ | |
| X(5) | 2-in. | ANSI/ASME B16.5 Class 150 | 316 SST | ★ | |
| F(5) | 3-in. | ANSI/ASME B16.5 Class 150 | 316 SST | ★ | |
| G(5) | 4-in. | ANSI/ASME B16.5 Class 150 | 316 SST | ★ | |
| Y(5) | 2-in. | ANSI/ASME B16.5 Class 300 | 316 SST | ★ | |
| H(5) | 3-in. | ANSI/ASME B16.5 Class 300 | 316 SST | ★ | |
| J(5) | 4-in. | ANSI/ASME B16.5 Class 300 | 316 SST | ★ | |
| Z(5) | 2-in. | ANSI/ASME B16.5 Class 600 | 316 SST | ★ | |||
| L(5) | 3-in. | ANSI/ASME B16.5 Class 600 | 316 SST | ★ | |||
| Q | DN 50 | PN 10-40 per EN 1092-1 | CS | ★ | |||
| R | DN 80 | PN 40 per EN 1092-1 | CS | ★ | |||
| S | DN 100 | PN 40 per EN 1092-1 | CS | ★ | |||
| V | DN 100 | PN 10/16 per EN 1092-1 | CS | ★ | |||
| K(5) | DN 50 | PN 10-40 per EN 1092-1 | 316 SST | ★ | |||
| T(5) | DN 80 | PN 40 per EN 1092-1 | 316 SST | ★ | |||
| U(5) | DN 100 | PN 40 per EN 1092-1 | 316 SST | ★ | |||
| W(5) | DN 100 | PN 10/16 per EN 1092-1 | 316 SST | ★ | |||
| 7(5) | 4 in. | ANSI/ASME B16.5 Class 600 | 316 SST | ★ | |||
| 1 | N/A | 10K per JIS B2238 | CS | ||||
| 2 | N/A | 20K per JIS B2238 | CS | ||||
| 3 | N/A | 40K per JIS B2238 | CS | ||||
| 4(5) | N/A | 10K per JIS B2238 | 316 SST | ||||
| 5(5) | N/A | 20K per JIS B2238 | 316 SST | ||||
| 6(5) | N/A | 40K per JIS B2238 | 316 SST | ||||
| Seal fill fluid (high side) | Specific gravity | Temperature limits (ambient temperature of 70° F [21° C]) | |||||
| D | Silicone 200 | 0.93 | –49 to 401 °F (–45 to 205 °C) | ★ | |||
| F | Silicone 200 for vacuum applications | 0.93 | For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor pressure curves in Rosemount DP Level Fill Fluid Specification Technical Note. | ★ | |||
| L | Dow Corning® 704 diffusion pump fluid | 1.07 | 32 to 401 °F (0 to 205 °C) | ★ | |||
| C | D.C. Silicone 704 for vacuum applications | 1.07 | For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor pressure curves in Rosemount DP Level Fill Fluid Specification Technical Note. | ★ | |||
| A | SYLTHERM™ XLT | 0.85 | –102 to 293 °F (–75 to 145 °C) | ★ | |||
| H | Inert (halocarbon) | 1.85 | –49 to 320 °F (–45 to 160 °C) | ★ | |||
| G | Glycerin and water | 1.13 | 5 to 203 °F (–15 to 95 °C) | ★ | |||
| N | Neobee® M-20 | 0.92 | 5 to 401 °F (–15 to 205 °C) | ★ | |||
| P | Propylene glycol and water | 1.02 | 5 to 203 F (–15 to 95 °C) | ★ | |||
| Low pressure side | |||||||
| Configuration | Flange adapter | Diaphragm material | Sensor fill fluid | ||||
| 11(5) | Gage | SST | 316L SST | Silicone | ★ | ||
| 21 | Differential | SST | 316L SST | Silicone | ★ | ||
| 22(5) | Differential | SST | Alloy C-276 | Silicone | ★ |
| 2A(6) | Differential | SST | 316L SST | Inert (halocarbon) | ★ |
| 2B(5) (6) | Differential | SST | Alloy C-276 | Inert (halocarbon) | ★ |
| 31(5) | Tuned-system assembly with remote seal | None | 316L SST | Silicone (requires option code S1) | ★ |
| O-ring | |||||
| A | Glass-filled PTFE | ★ | |||
| Housing material | Conduit entry size | ||||
| A | Aluminum | ½–14 NPT | ★ | ||
| B | Aluminum | M20 x 1.5 | ★ | ||
| E | Aluminum, ultra low copper | ½–14 NPT | |||
| F | Aluminum, ultra low copper | M20 x 1.5 | |||
| J | SST | ½–14 NPT | ★ | ||
| K | SST | M20 x 1.5 | ★ | ||
| P(7) | Engineered polymer | No conduit entries | ★ | ||
| D(8) | Aluminum | G½ | |||
| M(8) | SST | G½ | |||
| Wireless options (requires wireless output code X and Engineered Polymer Housing code P) | |||||
| Wireless transmit rate, operating frequency, and protocol | |||||
| WA3 | User configurable transmit rate, 2.4 GHz WirelessHART | ★ | |||
| Antenna and SmartPower | |||||
| WP5 | Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately) | ★ | |||
| Options (include with selected model number) | |||||
| Extended product warranty | |||||
| WR3 | 3-year limited warranty | ★ | |||
| WR5 | 5-year limited warranty | ★ | |||
| Plantweb™ control functionality(9) | |||||
| A01 | FOUNDATION Fieldbus Control Function Block Suite | ★ | |||
| Plantweb diagnostic functionality | |||||
| DA0(20) | Loop Integrity HART Diagnostic | ★ | |||
| D01(9) | FOUNDATION Fieldbus diagnostics suite | ★ | |||
| Seal assemblies(10) | |||||
| S1 | Assembled to One Rosemount 1199 Seal | ★ | |||
| Product certifications | |||||
| E8 | ATEX Flameproof and Dust Certification | ★ | |||
| I1(11) | ATEX Intrinsic Safety and Dust | ★ |
| IA | ATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only | ★ |
| N1 | ATEX Type n Certification and Dust | ★ |
| K8 | ATEX Flameproof, Intrinsic Safety, Type n, and Dust (combination of E8, I1, and N1) | ★ |
| E4(12) | TIIS Flameproof | ★ |
| E5 | FM Explosion-proof, Dust Ignition-proof | ★ |
| I5(13) | FM Intrinsically Safe, Nonincendive | ★ |
| IE | FM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only | ★ |
| K5 | FM Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2 | ★ |
| C6 | CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 | ★ |
| I6(7) | CSA Intrinsic Safety | ★ |
| K6 | CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1) | ★ |
| E7 | IECEx Flameproof, Dust Ignition-proof | ★ |
| I7 | IECEx Intrinsic Safety | ★ |
| N7 | IECEx Type n Certification | ★ |
| K7 | IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7) | ★ |
| E2 | INMETRO Flameproof | ★ |
| I2 | INMETRO Intrinsic Safety | ★ |
| IB | INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only | ★ |
| K2 | INMETRO Flameproof, Intrinsic Safety | ★ |
| E3 | China Flameproof | ★ |
| I3 | China Intrinsic Safety | ★ |
| N3 | China Type n | ★ |
| EM | Technical Regulations Customs Union (EAC) Flameproof | ★ |
| IM | Technical Regulations Customs Union (EAC) Intrinsic Safety | ★ |
| KM | Technical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety | ★ |
| KB | FM and CSA Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6) | ★ |
| KD | FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8) | ★ |
| EP(14) | Republic of Korea Flameproof | ★ |
| IP(15) | Republic of Korea Intrinsic Safety | ★ |
| KP(16) | Republic of Korea Flameproof, Intrinsic Safety | ★ |
| Shipboard approvals(7) | ||
| SBS | American Bureau of Shipping | ★ |
| SBV(17) | Bureau Veritas (BV) | |
| SDN | Det Norske Veritas | |
| SLL(17) | Lloyds Register (LR) | |
| Bolting material | ||
| L4 | Austenitic 316 SST bolts | ★ |
| L5 | ASTM A 193, grade B7M bolts | ★ |
| L6 | Alloy K-500 Bolts | ★ |
| L8 | ASTM A 193 Class 2, grade B8M bolts | ★ |
| Display and interface options | ||
| M4(18) | LCD display with LOI | ★ |
| M5 | LCD display | ★ |
| Calibration certification | ||
| Q4 | Calibration Certificate | ★ |
| QP | Calibration Certificate and tamper evident seal | ★ |
| QG(19) | Calibration Certificate and GOST Verification Certificate | ★ |
| Material traceability certification | ||
| Q8 | Material Traceability Certification per EN 10204 3.1 | ★ |
| Quality certification for safety(20) | ||
| QS | Prior-use certificate of FMEDA data | ★ |
| QT | Safety certified to IEC 61508 with certificate of FMEDA | ★ |
| Toolkit total system performance reports | ||
| QZ | Seal system performance calculation report | ★ |
| Conduit electrical connector(6) | ||
| GE | M12, 4-pin, male connector (eurofast) | ★ |
| GM | A size Mini, 4-pin, male connector (minifast) | ★ |
| Configuration buttons | ||
| D4(20) | Analog zero and span | ★ |
| DZ(21) | Digital zero trim | ★ |
| Transient protection(6)(22) | ||
| T1 | Transient protection | ★ |
| Software configuration(21) | ||
| C1 | Custom Software Configuration (For wired, see the Rosemount 3051 Configuration Data Sheet. For wireless, see the Rosemount 3051 Wireless Configuration Data Sheet.) | ★ |
| Low power output | ||
| C2 | 0.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only) | |
| Alarm levels(20) | ||
| C4(23) | NAMUR alarm and saturation levels, high alarm | ★ |
| CN(23) | NAMUR alarm and saturation levels, low alarm | ★ |
| CR | Custom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) | ★ | ||
| CS | Custom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) | ★ | ||
| CT | Rosemount Standard low alarm | ★ | ||
| Conduit plug | ||||
| DO | 316 SST Conduit Plug | ★ | ||
| Ground screw(6)(24) | ||||
| V5 | External ground screw assembly | ★ | ||
| Lower housing flushing connection options | ||||
| Ring material | Number | Size (NPT) | ||
| F1 | 316 SST | 1 | ¼–18 NPT | ★ |
| F2 | 316 SST | 2 | ¼–18 NPT | ★ |
| F3 | Alloy C-276 | 1 | ¼–18 NPT | ★ |
| F4 | Alloy C-276 | 2 | ¼–18 NPT | ★ |
| F7 | 316 SST | 1 | ½–14 NPT | ★ |
| F8 | 316 SST | 2 | ½–14 NPT | ★ |
| F9 | Alloy C-276 | 1 | ½–14 NPT | ★ |
| F0 | Alloy C-276 | 2 | ½–14 NPT | ★ |
| Lower housing intermediate gasket material | ||||
| S0 | No gasket for lower housing | ★ | ||
| SY(25) | Thermo-Tork® TN-9000 | ★ | ||
| NACE certificate(26) | ||||
| Q15 | Certificate of compliance to NACE MR0175/ISO 15156 for wetted materials | ★ | ||
| Q25 | Certificate of compliance to NACE MR0103 for wetted materials | ★ | ||
| HART Revision configuration(1) (requires HART protocol output code A) | ||||
| HR5 | Configured for HART Revision 5 | ★ | ||
| HR7 | Configured for HART Revision 7 | ★ | ||
| Typical model number: 3051L 2 A A0 D 21 A A F1 | ||||
Good Service in WTL :
> We offer high quality, fast delivery, competitive price for
Mitsubishi Servo Motor and Servo Drive.
> Please send your RFQ to get the latest price.
> Normally, we will ship the items in 1-2 weeks after receive
the payment.
> We can ship to you by UPS/DHL//EMS/Fedex. Please contact us
and we will use your preferred ways.
> We have a large stock and the prices are variable, so
sometimes the prices we post are not accurate.
If needed, please contact us for specific prices.
OUR MAIN BRAND:

|
| Company Info. |
| Wisdomlong Technology CO.,LTD |
| View Contact Details |
| Product List |