Sign In | Join Free | My burrillandco.com
Home > Used General Mechanical Components >

Forging Koomey Bop Control Unit Pneumatic Type Koomey Accumulator

    Buy cheap Forging Koomey Bop Control Unit Pneumatic Type Koomey Accumulator from wholesalers
     
    Buy cheap Forging Koomey Bop Control Unit Pneumatic Type Koomey Accumulator from wholesalers
    • Buy cheap Forging Koomey Bop Control Unit Pneumatic Type Koomey Accumulator from wholesalers

    Forging Koomey Bop Control Unit Pneumatic Type Koomey Accumulator

    Ask Lasest Price
    Brand Name : Hebei Pantu
    Model Number : FKQ960-6
    Certification : API 16D
    Price : USD 50000-100000 per set
    Payment Terms : T/T
    Supply Ability : 5 sets per 3 months
    Delivery Time : 7 work days
    • Product Details
    • Company Profile

    Forging Koomey Bop Control Unit Pneumatic Type Koomey Accumulator

    API 16D Koomey Bop Control Unit Pneumatic Type


    Koomey Bop Control Unit introduction


    1, The Remote Control panel is equipped with both electric pneumatic power, as well as a stand-by inlet for pressing oil to ensure the system working regularly even under unexpected situations.

    2, The power system is equipped with automatic control system and double protective device against overload pressure for hydraulic system. The operation is easy, safe and reliable.


    Koomey Bop Control Unit Parameters



    Item


    Model

    Number of Controlled ObjectsAccumulator SetsEffective Volume of Oil Reservoir (L)Flow Rate of PumpMotor Power (kW)Working Pressure (MPa)
    Total Volume

    (L)

    Nominal Available Volume (L)Electric Pump (L/min)Pneumatic Pump (ml/stroke)
    1FKQ240-3340×6120560201651121
    2FKQ320-4440×8160650201651121
    3FKQ320-5540×8160650201651121
    4FKQ400-5540×10200900301651521
    5FKQ400-6640×10200900301651521
    6FKQ480-5540×122401000301651521
    7FKQ480-6640×122401000301651521
    8FKQ640-6640×16320130040165×218.521
    9FKQ640-7740×16320130040165×218.521
    10FKQ800-7740×20400150040165×218.521
    11FKQ800-8840×20400160040165×218.521
    12FKQ960-6680×12480180040165×318.521
    13FKQ960-7780×12480180040165×318.521
    14FKQ960-8880×12480180040165×318.521
    15FKQ1280-8880×16640200040×2165×318.5×221
    16FKQ1280-9980×16640200040×2165×318.5×221
    17FKQ1280-101080×16640200040×2165×318.5×221
    18FKDQ480-5640×122401000301651521
    19FKDQ480-6640×122401000301651521
    20FKDQ640-6640×16320130040165×218.521
    21FKDQ640-7740×16320130040165×218.521
    22FKDQ800-7740×20400150040165×218.521
    23FKDQ800-8840×20400160040165×218.521
    24FKDQ960-7780×12480180040165×318.521
    25FKDQ960-8880×12480180040165×318.521
    26FKDQ1280-8880×16640200040×2165×318.5×221
    27FKDQ1280-9980×16640200040×2165×318.5×221
    28FKDQ1280-101080×16640200040×2165×318.5×221
    29FKD640-6640×16320130040165×218.521
    30FKD800-7740×20400150040165×218.521
    31FKD960-8880×12480180040165×318.521

    Key Points of BOP Control System selection


    To control BOP reliably and safely, oil & natural gas industry standards SY/T5053.2-2007 and APl Spec 16D should be followed when you choose and purchase a suitable product. Factors to be considered should at least be:


    1. Relationship between liquid volume required for closing BOP stacks and liquid volume available from the control system
    2. Whether it needs to meet the APl 16D standards;
    3. Environmental adaptation;
    4. Special requirements on the off-shore drilling platforms.

    1 Options for controlled objects and accumulator available liquid volume
    The accumulator group shall be configured so that the remaining pressure is greater than the maximum control pressure required
    by the control object after closing all BOP and hydraulic valves.
    Available volume from an accumulator group is recommended be 2 times greater than the required volume of closing BOP stacks.
    2. Requirements of pump system
    The main pumping unit shall be comprised of a minimum of two pump systems. The cumulative output capacity of the
    pump systems shall be sufficient to charge the main accumulator system from precharge pressure to the system RWP within
    15 minutes. With the loss of one pump system or one power system, the remaining pump system(s) shall have the capacity to
    charge the main accumulator system from precharge pressure to the system RWP within 30 minutes.
    With the accumulators isolated from service and with one pump system or one power system out of service, the remaining
    pump system(s) shall have the capacity to close one annular BOP and open choke valve(s) within 2 minutes.
    3. Whether it needs to meet the API 16D standards
    If the customer wants to order an API Spec. 16D control system, and mark the API monogram, the customer need to obtain
    a form named “configuration and parameters of the bop stacks for order an API Spec. 16D control system (land and surface)”
    from Rongsheng sales department. After filling in the detailed technical parameters, the Rongsheng technical department will
    carry out the selection calculation.

    Note:
    Q:The FKQ series uses hose bundle to connect the dillr's panel with the renole control pane ,the diler operating elemerti pneumatic rotar y valves,remotecontrol panel uses cylinder to drive the 4-way 3-position vave,tis series can choose pneumatic-manual o pneumatih motor drven pressure reguiating valves,

    DQ: The FKDQ series uses signal cableto connect the trller's panel with the renote contro panel ,theaillr operating e lemen is touch soreen r l ctic butonremote control panel uses cylinder to drive the 4-way 3-position valve, with pneumatic motor driven pressure regulating valves.
    D: The FKD series uses signal cableto connect the drllr's panel with the remote control panel,theotrlle operating elenent is touch screen o lectic buronremote control panel uses electromagnet to drive the 4-way 3-position valve, with electromotor driven pressure regulating valves.
    lf the customer want to order an APl Spec. 16D control systen, and you need to mark the APl monogram on it you need to obitain a fom named“configurationand peramelers of the bop stacks for ovder an APl Spec. 16D control system jland and surace)”from Rongsheng sales department. Afitr flng in the deti ledtechnical parameters, the Rongsheng technical department will carry out the selection calculation.
    The optional device:
    All series can choose BOP heating units, to heating bop in extremely cold ernvironment,ena ble the bop tofuncion normlly the BOP shouls haveheatirg ucto)FKDQ & FKD series can choose wireless remote control function.


    Quality Forging Koomey Bop Control Unit Pneumatic Type Koomey Accumulator for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Hebei E-valves Petroleum Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Blowout Preventer BOP products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0