Sign In | Join Free | My burrillandco.com
Home > Clamp Meters >

4000 Counts Pocket Clamp Digital Multimeter with NCV Flashlight Lighting

    Buy cheap 4000 Counts Pocket Clamp Digital Multimeter with NCV Flashlight Lighting from wholesalers
     
    Buy cheap 4000 Counts Pocket Clamp Digital Multimeter with NCV Flashlight Lighting from wholesalers
    • Buy cheap 4000 Counts Pocket Clamp Digital Multimeter with NCV Flashlight Lighting from wholesalers
    • Buy cheap 4000 Counts Pocket Clamp Digital Multimeter with NCV Flashlight Lighting from wholesalers
    • Buy cheap 4000 Counts Pocket Clamp Digital Multimeter with NCV Flashlight Lighting from wholesalers
    • Buy cheap 4000 Counts Pocket Clamp Digital Multimeter with NCV Flashlight Lighting from wholesalers

    4000 Counts Pocket Clamp Digital Multimeter with NCV Flashlight Lighting

    Ask Lasest Price
    Brand Name : VICTOR
    Model Number : VICTOR 606E
    Certification : CE
    Payment Terms : T/T, Western Union, L/C,Paypal
    Supply Ability : 10000 pc available
    Delivery Time : 5-30 days
    • Product Details
    • Company Profile

    4000 Counts Pocket Clamp Digital Multimeter with NCV Flashlight Lighting

    4000 Counts Pocket Clamp Digital Multimeter with NCV Flashlight Lighting


    VICTOR 606E 4000 Counts Pocket Clamp Digital Multimeter 3 3/4 AC DC Digital Clamp Meter Multimeter Pinza Amperimetrica True RMS


    1. SAFETY OPERATION RULE

    The meter’s design is in accordance with the CE certification, meets the standard ofIEC61010-1, IEC61010-2-032, IEC 61010-031, IEC61010 CAT.III 600V and Grade II pollution. Read the following before operation.

    1.1 Use the meter in accordance with the standards or requirements of this manual, otherwise the protection function provided by the instrument may be damaged or declined.

    1.2 To avoid electric shock, be careful when measuring the voltage higher than 60V DC RMS, 30V AC

    1.3 Do not input the voltage over the limit value between the terminals or between each terminal and ground.

    1.4 Check whether the meter works properly by measuring the voltage or current which were known beforehand. Do not use any more if it is improper or damaged.

    1.5 Please check the meter before operation, if the shell is cracked or the plastic parts are damaged, please stop using it again.

    1.6 Before operation, please check the test leads, if there are cracks or damage on it, please replace the test leads with same model or the same electrical specifications.

    1.7 Do not measure over range of the meter, accessories as probe, and CAT Level.

    1.8 When inserting the test leads in the input jack, do not measure the current

    1.9 Do not operate with the meter independently

    1.10 Please comply with local and national safety regulations. Wear personal protective equipment (such as approved rubber gloves, face masks, and flame-retardant clothing etc.) to prevent the injury from electric shock and arc when charged conductors are exposed.

    1.11 When the low battery symbol appears, please replace the battery in time to avoid the wrong values

    1.12 Do not use the meter in a humid environment with steam etc., or in the air with explosive gas.

    1.13 When using the test leads, please hold your finger behind the finger protective equipment of the probe.

    1.14 Please connect the neutral wire or ground wire first under measurement, and then connect the live wire. When the measurement ends, please disconnect the live wire first, and then disconnect the neutral wire and ground wire.

    1.15 Before opening the shell or battery cover, remove all probes or test leads. Do not use the meter when it is disassembled or the battery cover opened.


    Function
    DC Voltage (DCV)YESAC Voltage (ACV)YES
    DC Current (DCA)YESAC Current (ACA)YES
    ResistorYESFreauency/DutyYES
    CapacitorYESTemperature(°C/°F)YES
    NCV DeteationYESDiode TestYES
    True RMSYESDCA ZeroYES
    Auto offYESDouble BacklightYES
    Flashlight lightingYESData HoldYES

    Specification
    DC Voltage: 400mV/4V/40V/400V/600V;±(0.5%+5d)
    AC Voltage: 4V/40V/400V/600V;±(1.0%+5d)
    DC Current: 40A/400A/600A;50~60Hz±(2.5%+5d)
    AC Current: 40A/400A/600A;50~60Hz±(2.5%+5d);Other:±(3.0%+10d)
    Resistance: 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ;±(1.0%+5d)
    Capacitance: 10nF/100nF/1000nF/10µF/100µF/1000µF/10mF;±(4.0%+5d)
    Frequency: 10Hz/100Hz/1000Hz/10kHz/100kHz/1000kHz/10MHz;±(1.0%+3d)
    Duty: 1~99%
    Temperature: -20~1000°C(-4~1832°F)
    Display Counts: 4000 counts
    Jaw Size: 26mm
    Power: 2 x 1.5V AAA
    Product Size: 200*75*35mm
    Product Weight: 150g

    Quality 4000 Counts Pocket Clamp Digital Multimeter with NCV Flashlight Lighting for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: XI'AN BEICHENG ELECTRONICS CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Digital Clamp Multimeter products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0