Sign In | Join Free | My burrillandco.com
Home > Other Electrical Equipment >

Protection Level 2.5KV Lightning Protection For Photovoltaic System SGS Approved

    Buy cheap Protection Level 2.5KV Lightning Protection For Photovoltaic System SGS Approved from wholesalers
     
    Buy cheap Protection Level 2.5KV Lightning Protection For Photovoltaic System SGS Approved from wholesalers
    • Buy cheap Protection Level 2.5KV Lightning Protection For Photovoltaic System SGS Approved from wholesalers

    Protection Level 2.5KV Lightning Protection For Photovoltaic System SGS Approved

    Ask Lasest Price
    Brand Name : Uchi
    Model Number : OBV5-C40-PV
    Certification : CE / SGS / ISO9001
    Price : Negotiate
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : 60000 pieces per month
    Delivery Time : 5-15 days after payment
    • Product Details
    • Company Profile

    Protection Level 2.5KV Lightning Protection For Photovoltaic System SGS Approved

    Protection level (at In) Up <2.5kv PV Surge Protector, 600V Network voltage


    OBV5-C40-PV


    Prewired modular complete unit for use in photovoltaic systems consisting of a base part and plug-in protection modules

    Combined disconnection and short-circuiting device with safe electrical isolation in the protection module prevents fire damage resulting from d.c. switching arcs (patented SCI principle)

    Tried and tested fault-resistant Y circuit of the OBV6-C40-PV prevents damage to the surge protective device in case of insulation faults in the generator circuit.

    Integrated d.c. fuse allows safe replacement of protection modules without arc formation.


    Technical Parameters


    Model: OBV5-C40-PV
    Network voltage500Vdc600Vdc800Vdc900Vdc1000 Vdc
    Max. operating voltage Uc530Vdc630Vdc840Vdc950Vdc1060 Vdc
    Nominal discharge current ln20kA
    Max. discharge current lmax40kA
    Protection level (at In) Up1.8kV2.5kV2.8kV3.0kV3.2kV
    Disconnector
    Thermal DisconnectorInternal
    Mechanical characteristics
    Connectionby screw terminals: 4-25 mm2
    Disconnection indicator1 mechanical indicator by pole
    Mountingsymmetrical rail 35 mm
    Operating temperature-40/+85°C
    Protection classIP20
    Standards compliance
    NF EN 61643-11 FranceParafoudre Basse Tension - Essais Classe II
    IEC 61643-1 InternationalLow Voltage SPD - Test Class II
    EN 61643-11 EuropeParafoudre Basse Tension - Essais Classe II

    Feature&Benefits

    -Easy installation or retrofit

    -Din-rail mountable
    -Fail-safe /self-protected designRemote indicator (optional) with 3pin NO/NC contact
    -IP20 finger-safe designVisual indicator
    -Small foot print

    Application


    ●AC/DC distribution
    ●Power supplies
    ●Industrial automation
    ●Telecommunications
    ●Motor controls systems
    ●PLC applications
    ●Power transfer equipment
    ●HVAC applications
    ● AC drives
    ●UPS systems
    ●Security systems
    ●IT/Data centers

    Tip: Lightning protection is probabilistic protection, and we cannot provide 100% protection.


    First, lightning discharge itself has a certain degree of randomness, and lightning parameters have certain statistical properties, which determines that all protective measures based on these statistical characteristics of lightning parameters cannot provide 100% protection. Such as: direct lightning protection-shielding characteristics; lightning current amplitude, waveform, etc. have statistical properties;
    Second, the lightning protection equipment cannot prevent the formation of lightning flashes;
    Third, lightning protection devices cannot ideally eliminate all interference voltages/currents. The fundamental purpose of taking protective measures is to ensure that most of the energy caused by interference does not spread to the vulnerable parts of the device and the staff.
    Finally, the cost of protection against high-level surges with a small probability of occurrence has risen sharply.


    Others


    Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

    Type No.Rated Voltage(V) UnContinuous Voltage Uc(V~)Standard Discharge Current In(KA)

    Max Discharge Current
    Imax(KA)

    Protection Level(KA~)Response Time(ns)
    DGM1(2)-D5220/380

    275/320
    385/420

    5101.2≤25
    DGM1(2)-D101021.6
    DGM1(2)-C2020401.8
    DGM13-B303060.2.2
    DGM3(4)-B4010802.4
    DGM(4)-B60601002.8
    DGM-N-PE220/25540/6060/801.2≤100

    Surges in telecom andsignalling networks
    Surges tend to induce currents in allmetal conductors; not only are thepower lines affected, but so are allcables to a greater or lesser extent,depending on the distance to the focusof the surge.
    Although a lower current is induced,the effect produced is equally or moredestructive, due to the greatersensitivity of electronic equipmentconnected to communications lines(telephone, Ethernet, R, etc.).


    Importance of theground connection
    Overvoltage protectors (SPD) divert excess energy toground, so limiting the peak voltage to an acceptablevalue for connected electrical equipment.
    A ground connection in adequate condition is, therefore,a key aspect for effective protection against overvoltages.Monitoring ground connection condition guaranteesproper operation of surge protection devices.

    What skills should lightning protectors have in the selection?
    1.Confirm power supply system
    First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
    For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
    2.Know the main parameters of the lightning arrester.
    FAQ


    Q: Can I get some samples?
    A: Yes, Sample orders welcomed.

    Q: Can I use my own Logo or design on goods?
    A: Yes, Customized logo and design on mass production are available.

    Q:What is the delivery time?
    A: 3 days for samples, 7-15 days for mass production.

    Q: What is the payment term?
    A: T/T, L/C at sight, West union , Paypal, etc.

    Quality Protection Level 2.5KV Lightning Protection For Photovoltaic System SGS Approved for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Guangdong Uchi Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more PV Surge Protector products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0