outdoor input in the building and each floor Low voltage(200/380VAC)
industrial SPD
Model and specification AM40A
| Model | AM40A |
| MainTechnicalData | |
| UnNominalworkingvoltage(Un) | 230/400V |
| UcMaxcontinuousoperatingvoltage(Uc) | 385VAC |
| OperatingFrequency | 48-62Hz |
| Nominaldischargecurrent(kA) | 20kA |
| Maxdischargecurrent(kA) | 40kA |
| ProtectedMode | L1,L2,L3,N-PE(4P) |
| Protectionlevel(Up) | 1.8kV |
| Recommendmaxbackupfuse | 63A(gL/gG) |
| Responsetime | ≤25ns |
| Work/Faultindication | Localindicatewindow: |
| Green=SPDOK|White=SPDFailure | |
| Module | 4 |
| MechanicalSpecification | |
| InstallationLocation | Indoor |
| Installation | 35mmslideguide |
| Dimension(mm) | 95*72*65 |
| Cross-sectionalareamax | ≥25mm2 |
| Cross-sectionalareamin | L/N:2.5mm2,PE:6mm2 |
| Modeofconnection | Connectioninparallel |
| EnvironmentSpecification | |
| Workingconditions | Temperature-40℃~+85℃; |
| Relativehumidity≤95%;Height≤3km | |
| ProtectionLevel | IP20 |
| Enclosurematerial | ThermoplasticmaterialUL94V-0 |
Safety precautions:
· When the SPDboxis installed in final system,it must achieve all
therequirements of GB4943 (EN60950,IEC60950) standard;
· The equipment has to be installed by authorized professional
person, before installation, to cut offpowersupply,and prohibit
hot-line work from accidents
Application: ·
Single phase power SPDis suitable forsystempowerprotection,such as
power distributioncabinet,switch cabinet,switch cabinet,AC/DC
distribution board, etc. · Distribution boxwith outdoor input in
the building and each floor · Low voltage(200/380VAC) industrial
and civilpowergrid ·Automationmachine room,power supply panel of
converting station main control room
Features:
·Big discharger current capacity,lowresidualvoltage, quickresponse
· Lowe leakage current and rate of change · Heat isolation
technique, no fire disaster · Apply specigl shock fuse pieces,
withhiahreligbility ·Build-inremote alarm connect point,easy
toremote control · With power indicator to display working
condition ·Equipped with lightning counter,exactly to record
lightning stroke ·Temperature controlprotective circuit, built-in
heat protection. automatic release unit Excellent international
famous core component brand
Installation:
· 35mm slide guide installation way · Connect +/-and ground
terminal of power systemto+/-and ground terminalof SPD, then screw
up the bolts · ground line of SPDto lightning protection
systemground device · After wiring.please checkituntil everything
isgoingwell, toput into operation.
Product maintenance:
·The eauipment has to be installed byauthorized professional
person, before installation,to cut off power supply,and prohibit
hot-line work from accidents · The sectional area of wire must
reach technicaldemands · When the SPD box is installed in final
system,it must achieve all the requirements of GB4943
(EN60950,IEC60950)standard; · The product does notneed to be
maintained specially,but to inspect a fixed period ·
Afterthunderstorm season, it is normal that the indicator window is
red, but to change a new module or total product instantly · Once
there is afailure during systemoperation,please removethe SPD
device at first,if the systemcan operate normally,the deviceis
broken
Product standard
· GB18802.1low-voltage distributionsystemSP:performance demand and
test method; · YD/T 1235.1 Communication Station low-voltage power
system SPD technical requirement; ·YD/T 1235.2 Communication
Station low-voltage power system SPD test method;
|