Sign In | Join Free | My burrillandco.com
Home > Material Handling Equipment Parts >

G Series Save Energy Unit Cooler High Efficiency Use For Cold Room

    Buy cheap G Series Save Energy Unit Cooler High Efficiency Use For Cold Room from wholesalers
     
    Buy cheap G Series Save Energy Unit Cooler High Efficiency Use For Cold Room from wholesalers
    • Buy cheap G Series Save Energy Unit Cooler High Efficiency Use For Cold Room from wholesalers
    • Buy cheap G Series Save Energy Unit Cooler High Efficiency Use For Cold Room from wholesalers
    • Buy cheap G Series Save Energy Unit Cooler High Efficiency Use For Cold Room from wholesalers
    • Buy cheap G Series Save Energy Unit Cooler High Efficiency Use For Cold Room from wholesalers
    • Buy cheap G Series Save Energy Unit Cooler High Efficiency Use For Cold Room from wholesalers

    G Series Save Energy Unit Cooler High Efficiency Use For Cold Room

    Ask Lasest Price
    Brand Name : Kaideli
    Model Number : GUDL,GUDD,GUDJ
    Certification : CE,ISO9001-2008
    Price : $100.00 - $1,700.00/sets
    Payment Terms : TT,LC,Western Union
    Supply Ability : 2000 Set/Sets per Month
    Delivery Time : 10-15 days
    • Product Details
    • Company Profile

    G Series Save Energy Unit Cooler High Efficiency Use For Cold Room

    •Founded in 1995, Zhejiang Kaidi Refrigeration Equipment Co., Ltd. is a large manufacturing company with a full organization of research and development, processing and manufacturing, sales and commissioning services.

    The headquarter is located in Shengzhou City, Zhejiang Province, covers an area of ​​50,000 square meters. It is equipped with advanced CNC processing equipment and high standard laboratories, also has experienced professional technical team and manufacturing team. We successfully obtained the certificates of ISO 9001,CE , industrial product production license and the special equipment manufacturing license from government (pressure vessel D1, D2).


    1. Product Introduction:

    • Shell: High-quality steel plate applied with low-temperature resistant powder with strong corrosion resistance performance. Aluminum plate or stainless-steel shells can also be customized. All tube plates are made of 2.0 thick aluminum alloy plates in order to minimize the possibility of internal leakage caused by heat exchange copper tube wearing ascribed to thermal expansion and contraction.
    • Double-layer water tray: The outer water tray plate is in hinged lap design form, which facilitates inspection and maintenance. Ribbing slope design at the bottom of water tray could speed up drainage and avoid icing and corrosion. The inner water tray is covered with aluminum plate to reduce air bypass and improve fan efficiency and defrosting effect.
    • Heat exchange pipe: Efficient internal thread pipe from premium brand with optimized loop, and positive triangle staggered design in order to improve heat exchange efficiency.
    • Fin: Classic Europe-style sinusoid corrugated aluminum fin, which could improve air disturbance and enhance heat exchange capacity at air side significantly.
    • Fan: Customized high-power fan with external rotor (operating temperature: -40℃~60℃). Insulation class of motor: Grade F, which could ensure stability and reliability;
    • Defrosting: Stainless steel electric heating pipe with a low power and density. It is reasonably arranged inside coil and on the inner water pan to ensure more uniform heating effect, increase defrosting effect and prolong the service life of electric heating pipe.
    • Electrical junction box: Special customized electrical junction box, which could resist water, fire and high-voltage and be wired easily.
    • Factory testing: Air cooler is cleaned and inspected and has passed 25bar pressure holding test prior to delivery.
    • Sheet spacing: Standard values: 4.5mm, 6.0mm and 9.0mm, in order to meet different temperature and humidity requirements.
    • Different refrigerants: Meet the requirements of refrigerants including R404A, R507A, R134a, R22, etc.

    2. Technical Parameters List
    Technical parameters of efficient air cooler of electric defrosting ceiling Spacing: 4.5mm

    ModelRefrigerating capacity kWTube volumeFan parametersDefrosting (electric heating)
    SC1SC2dm3风叶数量X直径
    Number X diameter of fans
    功率W
    Power W
    风量m3/h
    Air volume m3/h
    射程m
    Range m
    盘管kW*支
    Coil kW * pcs
    水盘kW*支
    Water tray kW * pcs
    GUDL501C6.74.63.21X∅5001X4145000120.28*60.28*2
    GUDL501D8.15.64.31X∅5001X4604900120.30*60.30*2
    GUDL501E9.86.75.41X∅5001X4604500120.30*80.30*2
    GUDL601E16.611.49.21X∅6001X7807500150.40*80.4*2
    GUDL502D22.215.311.82X∅5002X46011500130.72*60.72*2
    GUDL602D28.919.914.72X∅6002X78016500160.72*100.72*2
    GUDL602E33.823.318.42X∅6002X78015200160.72*100.72*2
    GUDL602F37.826.122.12X∅6002X78014500160.72*100.72*2
    GUDL632D40.728.123.72X∅6302X80019000190.95*100.95*2
    GUDL632E44.130.426.92X∅6302X80018000190.87*120.87*4
    GUDL603F54.537.632.33X∅6003X78020500171.03*121.03*4
    GUDL633F66.846.138.83X∅6303X80025500201.03*141.03*4


    Technical parameters of efficient air cooler of electric defrosting ceiling Spacing: 6.0mm

    ModelRefrigerating capacity kWTube volumeFan parametersDefrosting (electric heating)
    SC1SC2SC3dm3Number X diameter of fansPower WAir volume m3/hRange mCoil kW * pcsWater tray kW * pcs
    GUDD501C5.64.03.23.21X∅5001X4145200120.28*80.28*2
    GUDD501D7.15.14.04.31X∅5001X4605100120.30*80.30*2
    GUDD501E8.25.94.65.41X∅5001X4604800120.30*100.30*2
    GUDD601E14.410.38.19.21X∅6001X7808200150.40*100.4*2
    GUDD502D18.313.110.311.82X∅5002X46012000130.72*80.72*2
    GUDD602D24.117.213.614.72X∅6002X78017000160.72*120.72*2
    GUDD602E29.120.816.418.42X∅6002X78016400160.72*120.72*2
    GUDD602F32.122.918.122.12X∅6002X78015500160.72*120.72*2
    GUDD632D33.724.119.023.72X∅6302X80020000190.95*120.95*2
    GUDD632E37.226.621.026.92X∅6302X80019000190.87*120.87*4
    GUDD603F46.833.426.432.33X∅6003X78022000171.03*121.03*4
    GUDD633F56.740.532.038.83X∅6303X80026500201.03*141.03*4

    Technical parameters of efficient air cooler of electric defrosting ceiling Spacing: 9.0mm

    ModelRefrigerating capacity kWTube capacityFan parametersDefrosting (electric heating)
    SC3SC4SC5dm3Number X diameter of fansPower WAir volume m3/hRange mCoil kW * pcsWater tray kW * pcs
    GUDJ501C2.52.01.93.21X∅5001X4145300120.28*80.28*2
    GUDJ501D3.32.62.54.31X∅5001X4605500120.30*80.30*2
    GUDJ501E3.73.02.95.41X∅5001X4605100120.30*100.30*2
    GUDJ601E6.55.25.09.21X∅6001X7808300150.40*100.4*2
    GUDJ502D8.36.66.311.82X∅5002X46012500130.72*80.72*2
    GUDJ602D10.88.57.814.72X∅6002X78017500160.72*120.72*2
    GUDJ602E13.310.610.218.42X∅6002X78017000160.72*120.72*2
    GUDJ602F14.511.611.122.12X∅6002X78016000160.72*120.72*2
    GUDJ632D15.812.612.123.72X∅6302X80021000190.95*120.95*2
    GUDJ632E17.714.113.526.92X∅6302X80020500190.87*120.87*4
    GUDJ603F21.417.116.432.33X∅6003X78023000171.03*121.03*4
    GUDJ633F25.420.319.538.83X∅6303X80027000201.03*141.03*4


    Overall dimensions and installation size of efficient air cooler of electric defrosting ceiling Spacing: 4.5mm

    ModelInterface specification (mm)Overall dimensions B*T*HInstallation DimensionsweightsOutline icon
    Inlet pipe/return pipeDrainage (inches)L * W* H (mm): 610* 1,250*1,040LE1E2E3Fkg
    GUDL501C∅12/∅22G3/4952*400*674340640//12636A
    GUDL501D∅12/∅22G3/4952*400*674340640//12638A
    GUDL501E∅12/∅22G1952*490*674430640//12644A
    GUDL601E∅16/∅28G11172*490*831430860//12656A
    GUDL502D∅16/∅35G11992*400*680340840840/12680B
    GUDL602D∅22/∅42G1-1/21992*400*831340840840/12695B
    GUDL602E∅22/∅42G1-1/21992*490*831430840840/126115B
    GUDL602F∅22/∅42G1-1/21992*490*831430840840/126125B
    GUDL632D∅22/∅42G1-1/22552*400*98434011201120/126144B
    GUDL632E∅22/∅42G1-1/22352*490*98443010201020/126160B
    GUDL603F∅25/∅50G1-1/22751*490*831430813813813126166C
    GUDL633F∅25/∅50G22751*490*984430813813813126196C

    Overall dimensions and installation size of efficient air cooler of electric defrosting ceiling Spacing: 6.0mm

    ModelInterface specification (mm)Overall dimensions B*T*HInstallation DimensionsweightsOutline icon
    Inlet pipe/return pipeDrainage (inches)L * W* H (mm): 610* 1,250*1,040LE1E2E3Fkg
    GUDD501C∅12/∅22G3/4952*400*674340640//12635A
    GUDD501D∅12/∅22G3/4952*400*674340640//12637A
    GUDD501E∅12/∅22G1952*490*674430640//12643A
    GUDD601E∅16/∅28G11172*490*831430860//12657A
    GUDD502D∅16/∅35G11992*400*680340840840/12678B
    GUDD602D∅22/∅42G1-1/21992*400*831340840840/12693B
    GUDD602E∅22/∅42G1-1/21992*490*831430840840/126112B
    GUDD602F∅22/∅42G1-1/21992*490*831430840840/126122B
    GUDD632D∅22/∅42G1-1/22552*400*98434011201120/126140B
    GUDD632E∅22/∅42G1-1/22352*490*98443010201020/126154B
    GUDD603F∅25/∅50G1-1/22751*490*831430813813813126162C
    GUDD633F∅25/∅50G22751*490*984430813813813126192C


    Overall dimensions and installation size of efficient air cooler of electric defrosting ceiling Spacing: 9.0mm

    ModelInterface specification (mm)Overall dimensions B*T*HInstallation DimensionsweightsOutline icon
    Inlet pipe/return pipeDrainage (inches)L * W* H (mm): 610* 1,250*1,040LE1E2E3Fkg
    GUDJ501C∅12/∅22G3/4952*400*674340640//12634A
    GUDJ501D∅12/∅22G3/4952*400*674340640//12636A
    GUDJ501E∅12/∅22G1952*490*674430640//12642A
    GUDJ601E∅16/∅28G11172*490*831430860//12655A
    GUDJ502D∅16/∅35G11992*400*680340840840/12676B
    GUDJ602D∅22/∅42G1-1/21992*400*831340840840/12694B
    GUDJ602E∅22/∅42G1-1/21992*490*831430840840/126114B
    GUDJ602F∅22/∅42G1-1/21992*490*831430840840/126121B
    GUDJ632D∅22/∅42G1-1/22552*400*98434011201120/126139B
    GUDJ632E∅22/∅42G1-1/22352*490*98443010201020/126160B
    GUDJ603F∅25/∅50G1-1/22751*490*831430813813813126162C
    GUDJ633F∅25/∅50G22751*490*984430813813813126190C

    3. Product Outline View



    Note 1: Design Criteria

    Standard heat exchange conditionsInlet air temperatureEvaporation temperatureRelative humidityMoisture absorption coefficientDegree of superheat
    SC110℃0℃85%1.356.5K
    SC20℃-8℃85%1.155.2K
    SC3-18℃-25℃95%1.054.6K
    SC4-25℃-31℃95%1.013.9K
    SC5-34℃-40℃95%1.013.9K

    Note 2: Refrigerant conversion coefficient

    RefrigerantWorking conditionsR22R404AR507R134a
    Correction factorSC10.95110.93
    Correction factorSC20.95110.91
    Correction factorSC30.95110.85

    Quality G Series Save Energy Unit Cooler High Efficiency Use For Cold Room for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: ZHEJIANG KAIDI REFRIGERATION EQUIPMENT CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Cold Room Air Cooler products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0