Sign In | Join Free | My burrillandco.com
Home >

Patient Bedside Monitor ECG Board Mindray MEC2000 PM7000 PM8000 PM9000

    Buy cheap Patient Bedside Monitor ECG Board Mindray MEC2000 PM7000 PM8000 PM9000 from wholesalers
     
    Buy cheap Patient Bedside Monitor ECG Board Mindray MEC2000 PM7000 PM8000 PM9000 from wholesalers
    • Buy cheap Patient Bedside Monitor ECG Board Mindray MEC2000 PM7000 PM8000 PM9000 from wholesalers
    • Buy cheap Patient Bedside Monitor ECG Board Mindray MEC2000 PM7000 PM8000 PM9000 from wholesalers
    • Buy cheap Patient Bedside Monitor ECG Board Mindray MEC2000 PM7000 PM8000 PM9000 from wholesalers
    • Buy cheap Patient Bedside Monitor ECG Board Mindray MEC2000 PM7000 PM8000 PM9000 from wholesalers

    Patient Bedside Monitor ECG Board Mindray MEC2000 PM7000 PM8000 PM9000

    Ask Lasest Price
    Brand Name : Mindray
    Model Number : MEC2000 PM7000 PM8000 PM9000
    Payment Terms : T/T, Western Union,PayPal
    Delivery Time : 3-5 working days
    • Product Details
    • Company Profile

    Patient Bedside Monitor ECG Board Mindray MEC2000 PM7000 PM8000 PM9000


    Mindray MEC2000 PM7000 PM8000 PM9000 patient monitor ECG board


    ►Brief Introduction

    This module is designed to measure three parameters including ECG, RESP and TEMP.


    Specifications

    Sensitivity1 V/mv + 5%(reference 10Hz)
    Impedance50 (ohm)
    Signal DelayECG:25ms
    Signal Range± 8 (mV) p-p

    Functions

    This module uses ECG cables and TEMP sensors to collect ECG, RESP and TEMP signals,

    process them and transmit them to the main board through serial port.

    ECG Signal Input Circuit

    Input protection and filter circuit: receives ECG signals from ECG cables, removes high-frequency interference and prevents the circuit from being damaged by high voltage generated in defibrillation and ESD.

    Right leg drive circuit: picks up 50/60Hz common-mode signals in lead wire and feeds them back to patient body; suppresses the common-mode interference in lead wire for the sake of better detecting ECG signals.

    Lead Off detection circuit: detects if any ECG lead falls off and transmits relevant message to CPU.

    ECG Signal Process Circuit

    Differential Amplification circuit: first-order amplifies ECG signals and suppresses common-mode interference at the same time.

    Low-pass filter circuit: removes high-frequency interference outside frequency band of ECG signals.

    PACE signals are ECG pacing signals, which greatly affect ECG detecting performance.

    Therefore PACE suppression circuit is designed to suppress PACE signals in order to better detect ECG signals.

    Master AMP/Filter circuit: amplifies and filters ECG signals again and transmits them furthermore into A/D converter.

    Pace Detect

    Pick PACE signals out of ECG signals and transmit them to CPU.

    Temperature Detect Circuit

    Receive signals coming from TEMP sensor, amplify and filter the signals and transmit them furthermore into A/D converter.

    Carrier Generate Circuit

    RESP measurement is based on Impedance method. Respiration causes the changes of thoracic impedances, which feature is taken advantage to modulate the amplitude of high frequency carrier. The modulated signals are then sent into the measuring circuit. This circuit is designed to generate high frequency carrier

    RESP Signal Input Circuit

    Couples the RESP signals into the detection circuit.

    RESP Signal Process Circuit

    Preamplifier circuit: amplifies and filters RESP signals;

    Detection circuit: picks out the RESP wave modulated in excitation signals;

    Level translation circuit: removes DC components in RESP signals;

    Master AMP/Filter circuit: amplifies and filters RESP signals again and transmits them furthermore into A/D converter.

    A/D

    Convert analog signals output from each parameter circuit into digital signals, and send them into CPU part to receive further processing.

    CPU System

    Realize logic control over all parameter parts and A/D part.

    Process data of each parameter;

    Communicate with main board.

    Power & Signal Isolate Circuit

    Realize isolation from external circuit in order to ensure human safety;

    Provide power supplies for circuits;

    Realize isolating communication between CPU System and main board.


    ► About Us


    We have supply the Parts, Accessories and medical equipment of Patient Monitor, Defibrillator Machine, ECG Machine, Ventilator, Anesthesia Machine, Ultrasound such as

    • GE,
    • PHiliphhilip,
    • Mindray,
    • Goldway,
    • Nihon Kohden,
    • Med-tronic,
    • Masima,
    • Drager,
    • Edan,
    • Zoll,

    etc.


    If you want to explore more details about Mindray MEC2000 PM7000 PM8000 PM9000 Patient Bedside Monitor ECG board, please let us know. Looking forward to receiving your early inquiry.


    Quality Patient Bedside Monitor ECG Board Mindray MEC2000 PM7000 PM8000 PM9000 for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: China World Technology Medical Equipment Service Group
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Patient Monitor Parts products from this supplier
    Inquiry Cart 0