    Brand Name : Huaying
    Model Number : HYVA-405
    Certification : ISO, CE
    Price : Negotiable
    Payment Terms : T/T L/C
    Supply Ability : 50 sets per month
    Delivery Time : 7 Working Days
    • Product Details
    • Company Profile

    Multi Function CT PT Test Set CT PT Analyzer High Accuracy 500 VA 15 Kg Weight

    Multi Function CT PT Test Set CT PT Analyzer High Accuracy 500 VA 15 Kg Weight


    Equipment Description:

    This analyzer HYVA-405 can be called transformers dynamic characteristics tester, voltage and current transformers dynamic characteristics tester, transformer synthesized tester, transformer volt-ampere characteristic tester, CTPT synthesized tester, CT volt-ampere characteristics tester, PT volt-ampere characteristics tester, transformer characteristics synthesized tester, transformer transient characteristics tester, the voltage, ratio change, polarity synthesized tester.

    Technical parameters:

    1. input voltage: AC220V ± 10%, 50Hz / 60Hz ± 10%
    2. output voltage: 0.1 ~ 180V (AC)
    3. output current: 0.001 ~ 5A (RMS)
    4. output power: 500VA
    5. the maximum equivalent inflection voltage: 45KV
    6. the current measurement: Range: 0 ~ 10A (autoranging 0.1 / 0.4 / 2 / 10A)
    7. the voltage measurement: Range: 0 ~ 200V (autoranging 1/10/70 / 200V)
    8. turns ratio measurement: Range: 1 to 35,000,
    9. phase measurement: Accuracy: ± 2min, Resolution: 0.01min
    10. secondary winding resistance measurement range: Range: 0 ~ 8KΩ (autoranging 2/20 / 80Ω / 800Ω / 8kΩ)
    11. Working conditions: Temperature: -10 ℃ ~ 50 ℃, humidity: ≤90%
    12. Size: 485mm × 356mm × 183mm
    13. Weight: 15Kg


    Technical Parameters:

    1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
    2 Power supply: AC220V±10%, 50/60Hz±10%
    3 Voltage output: 0.1~180V (AC)
    4 Current output: 0.001~5A(RMS)
    5 Power output: 500VA
    6 Maximum knee voltage measurement: 45KV
    7 Current measurement:
    Range: 0~10A (automatically change range in 0.1/0.4/2/10A)
    Error: <±0.1%+0.01%FS
    8 Voltage measurement:
    Range: 0~200V (automatically change range in 1V/10V/70V/200V)
    Error: < ±0.1%+0.01%FS
    9 Turns ratio measurement:
    Range:1~35000
    1~2000 error<0.05%
    2000~5000 error<0.1%
    5000~35000 error<0.2%
    10 Phase measurement: error: ±2min; resolution: 0.01min
    11 Winding resistance measurement:
    Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
    Error: < 0.2%RDG+0.02%FS
    Maximum resolution: 0.1mΩ
    12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree
    13 CT Secondary burden:
    Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
    Error: <0.2%RDG+0.02%FS
    Maximum resolution: 0.001ohm
    14 PT Secondary burden:
    Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
    Error :<0.2%RDG+0.02%FS
    Maximum resolution: 0.1ohm
    15 PT ratio measurement:
    Range: 1~35000
    1~10000 error<0.1%
    10000~35000 error<0.2%
    16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%
    17 PT phase angle measurement: maximum error < 3min
    18 Make evaluation for test results according to selected standards
    19 Make word report for test result
    20 Make word reports one time for multi-group test records on the PC
    21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
    22 Compare excitation curves with saved excitation curves in the same window
    23 Memory capacity: >1000 groups test results
    24 Working condition: temperature: -10℃~50℃; moist: ≤90%


    Quality Multi Function CT PT Test Set CT PT Analyzer High Accuracy 500 VA 15 Kg Weight for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Wuhan Huaying Electric Power Tech & Science Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more CT PT Test Set products from this supplier
    Inquiry Cart 0