Sign In | Join Free | My burrillandco.com
Home > Apparel & Textile Machinery >

Radar Level Gauge For Monitor Tank Level, Working Humidity 0~95% Supply Voltage 9~24V

    Buy cheap Radar Level Gauge For Monitor Tank Level, Working Humidity 0~95% Supply Voltage 9~24V from wholesalers
     
    Buy cheap Radar Level Gauge For Monitor Tank Level, Working Humidity 0~95% Supply Voltage 9~24V from wholesalers
    • Buy cheap Radar Level Gauge For Monitor Tank Level, Working Humidity 0~95% Supply Voltage 9~24V from wholesalers
    • Buy cheap Radar Level Gauge For Monitor Tank Level, Working Humidity 0~95% Supply Voltage 9~24V from wholesalers
    • Buy cheap Radar Level Gauge For Monitor Tank Level, Working Humidity 0~95% Supply Voltage 9~24V from wholesalers
    • Buy cheap Radar Level Gauge For Monitor Tank Level, Working Humidity 0~95% Supply Voltage 9~24V from wholesalers

    Radar Level Gauge For Monitor Tank Level, Working Humidity 0~95% Supply Voltage 9~24V

    Ask Lasest Price
    Brand Name : Kacise
    Model Number : KWL801B
    Certification : certificate of explosion-proof, CE
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 1000 Pieces per Week
    Delivery Time : 5-8 working days
    • Product Details
    • Company Profile

    Radar Level Gauge For Monitor Tank Level, Working Humidity 0~95% Supply Voltage 9~24V

    1.Introduction


    1.1 Product Overview


    KWL801B-RS485 radar level sensor conforms to the standard specifications outlined in national standard DB50/T 826-2017 for level meters. Its core component is designed with a fully sealed IP68 waterproofing.

    The maximum measurement range of the product extends up to 40 meters, with a minimal blind spot of less than 6 cms.

    Due to its higher frequency and broader bandwidth, it achieves superior accuracy. Additionally, the product includes a fixed bracket for installation.


    1.2 Detection principle


    Radar level sensor is based on the principle of time domain reflection (TDR). The electromagnetic pulse propagates along the cable or probe with the speed of light. When it meets the surface of the measured medium, part of the pulse of the radar level meter is reflected to form an echo return to the pulse transmitter along the same path, and the distance between the transmitter and the surface of the measured medium is In direct proportion as the propagation time of the pulse, hence the height of the level is calculated.



    2.Feature

    • Based on the self-developed CMOS millimeter-wave RF chip
    • More compact RF architecture
    • Higher signal-to-noise ratio
    • Smaller dead zone
    • 5GHz working bandwidth
    • Higher measurement resolution and measurement accuracy
    • Less influence by the interference in the installation environment
    • More convenient of installation and
    • Modern design of integrated flat antenna

    3.Technical Specifications

    ModelKWL801B-RS485
    Frequency of measurement80GHz
    CommunicationRS485
    Frequency of acquisition≥200ms/ configurable
    Current of operation12V/14mA
    Distance measurement accuracy±2mm
    Communication protocolModbus/ Text protocol
    Antenna beam width±2.75°
    Supply voltage9~24V
    Range of measurement

    0.2~40m

    0.18~30m

    0.1~15/20m

    0.06~3/5/10m

    RF pulse current100mA/20ms
    Working humidity0~95%
    Type of threadG thread/ customized
    Working temperature-40~75℃
    Grade of water resistanceIP68
    Net weight0.6kgs

    4.Wiring Instructions


    Red lineVCC (9~24V power supply)
    Black lineGND
    Yellow line485-A
    Green line485-B


    5.Dimension



    6.Installation instructions


    6.1 Inspection before installation


    (1) Take the sensor out of the packaging box, carefully check the packing list according to the instruction manual, and check whether the equipment accessories are complete .

    (2) Carefully read the product instruction manual and product certificate .

    (3) Check whether there is any damage to the appearance of the instrument, especially whether the main unit is intact, and be careful to place the main unit properly to prevent it from being knocked over.


    6.2 Radar level sensor installation


    6.2.1 Check before installation


    Please check before installing the sensor as follows:

    Whether there are trees or other debris above the medium at the installation site.

    Whether the mounting bracket is installed horizontally.

    When the mounting bracket cannot be installed horizontally, you need to adjust the bracket according to gradienter on the surface of the sensor to make sure the sensor is in a horizontal position.


    6.2.2 Installation


    (1) Ensure that the sensor is perpendicular to the medium surface.

    (2) Avoid the transmitting beam from irradiating interference objects and generating false echoes.

    See the following for typical working conditions:



    Installation of upper thread Installation of lower thread



    Ensure that the radar level meter is installed perpendicular to the medium surface.

    Inclination will weaken the received signal amplitude and affect normal ranging.


    Attention:

    Try to keep the sensor fixed to avoid jitter when installing, and keep the surrounding environment as open as possible.

    1. The distance between the sensor and the medium surface is higher than 30cm to ensure that the front face of the sensor (antenna) is perpendicular to the measuring medium.

    2. The distance between the sensor and the edge of the tank, the edge of the pool, the edge of the river dam and the edge of the pool is greater than 0.5 meters;

    3. Select the position of the water surface with small fluctuations to install the module (try not to install in the water injection port, outlet and other water surface with large fluctuations, the greater the water surface fluctuation, the worse the measurement accuracy)


    ​7.MODBUS-RTU communication protocol


    7.1 MODBUS protocol


    1. Communication protocol hardware interface parameters

    The sensor uses serial port communication, and the default parameters are as follows :

    Communication ParametersSerial Port LevelBaud RateParity CheckData LengthStop Bit
    Serial PortTTL9600None81

    Timeout between frames 50ms.


    2. Communication protocol format


    The water level gauge communicates externally using the Modbus RTU communication protocol. Each complete data frame includes: address field, Function Code, data, and checksum. The checksum is the CRC16 check data of the data frame, with the low byte preceding the high byte. The default factory address for the sensor is 0x7F.

    Request command format and radar reply data format are described as follows:

    (1) Query parameter format: Function Code 0x03


    Request:

    Device AddressFunction CodeRegister AddressNumber of RegistersC R C
    1 Byte1 Byte2 Bytes2 Bytes2 Bytes

    Reply:

    Device AddressFunction CodeData LengthRegister ValueC R C
    1 Byte1 Byte1 Byte2N Bytes2 Bytes

    N: numbers of registers


    (2) Query parameter format: Function Code 0x04


    Request:

    Device AddressFunction CodeRegister AddressNumber of RegistersC R C
    1 Byte1 Byte2 Bytes2 Bytes2 Bytes

    Reply:

    Device AddressFunction CodeData LengthRegister ValueC R C
    1 Byte1 Byte1 Byte2N Bytes2 Bytes

    N: numbers of registers


    (3) Set parameter format: Function Code 0x10


    Request:

    Device AddressFunction CodeRegister AddressNumber of RegistersData LengthRegister ValueC R C
    1 Byte1 Byte2 Bytes2 Bytes1 Byte2N Bytes2 Bytes

    Reply:

    Device AddressFunction CodeRegister AddressNumber of RegistersC R C
    1 Byte1 Byte2 Bytes2N Bytes2 Bytes

    N: numbers of registers


    3. Register Address Summary Table


    Parameter Default
    ParameterRegister Address

    PLC Or Group

    Status Address

    Support Function CodeType Of DataIllustrate
    Slave Address​0x2001481940x03,0x10int16

    int16 For 2 Bytes Integer ;

    int32 For 4 Byte Integer , High

    16 In Front

    Baud Rate0x2002481950x03,0x10int32
    Version Information0x2004481970x03int32
    Set Up Calibration0x2052482750x03,0x10int16

    Automatic Push

    Cycle

    0x2053482760x03,0x10int16
    Blind Spot0x2044482610x03Float(little 16)Float(little 16) is 4 byte float , low 16th place first
    Measuring Range0x2046482630x03Float(little 16)

    Set Current

    Depth

    0X2048482650x03,0x10Float(little 16)

    Set Up Installation

    High

    0x204A482670x03,0x10Float(little 16)
    Level0x0A0B325720x04Float(little 16)
    Empty Height0xaof325760x04Float(little 16)

    Note: The Register Address and data type of some parameters can be modified by the host computer software. After modifying the Register Address or data type, the corresponding Modbus operation instructions will also change accordingly, such as: The default instruction to read the empty height is 0x 7F 04 0A 0F 00 02 48 0E. If the register of the empty height is modified to 00 01, the instruction to read the empty height is changed to 0x 7F 04 00 01 00 02 2A 15.


    4. Communication protocol command description

    Note:

    a. The default Device Address is 0x7F;

    b. The float type data in the data adopts IEEE754 binary floating point arithmetic standard, the low 16 bits in the first (CDAB);

    c. In the following example, the Register Address corresponding to each parameter is the default address. If the address of the register is modified by the host computer, the Register Address in the Modbus operation instruction should be changed accordingly;

    d. In the following example, the data definition (data type/unit) of each parameter is parsed according to the default configuration. If the data definition (data type/unit) is modified through the host computer, the data reading and parsing should be modified accordingly;


    7.2 Query data instruction: Function Code 0x04

    7.2.1 Query measurement results - level (i.e. installation height - air height)

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x040x0A 0B0x00 020x09 CF

    Reply data:

    Device AddressFunction CodeLength of DataDataCRC
    0x7F0x040x040x00 00 41 300x09 CF

    Data definition: The default data type is float(little16) data, the default unit is meters (m), the data length is 4 bytes, and the lowest 16 bits are in the first.

    Error code:

    ① When the installation height is not set, the level cannot be calculated, and the output 0xFC FC FC FC ;

    ② When the measurement results exceed the range, output 0xFF FF FF FF;

    ③ When the sensor is in the blind area, output 0xFE FE FE FE;

    ④ When the sensor echo energy is insufficient, the output 0xFD FD FD FD;

    Example 1:

    Request: 7F 04 0A 0B 00 02 09 CF

    Reply: 7F 04 04 00 00 41 30 55 C7

    The data part 0x 00 00 41 30 is converted to floating point data, that is, 11.00 m.

    Example 2:

    Request: 7F 04 0A 0B 00 02 09 CF

    Re: 7F 04 04 FC FC FC FC D4 A2

    In the data part, 0x FC FC FC FC is an error code, indicating that the mounting height is not set (the level cannot be calculated).


    7.2.2 Query measurement results - air height

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x040x0A 0F0x00 020x48 0E

    Reply data:

    Device AddressFunction CodeLength of DataDataCRC
    0x7F0x040x040x31 13 40 100xAA B6

    Data definition: The default data type is float(little16) data, the default unit is meters (m), the data length is 4 bytes, and the lowest 16 bits are in the first.

    Error code:

    ① When the measurement results exceed the range, output 0xFF FF FF FF;

    ② When the sensor is in the blind area, output 0xFE FE FE FE;

    ③ When the sensor echo energy is insufficient, the output 0xFD FD FD FD FD;

    Example 1:

    Request: 7F 04 0A 0F 00 02 48 0E

    Reply: 7F 04 04 31 13 40 10 AA B6

    The data part 0x 31 13 40 10 is converted to floating point data, that is, 2.253 m.

    Example 2:

    Request: 7F 04 0A 0F 00 02 48 0E

    Reply: 7F 04 04 FE FE FE F4 7B

    The data part 0x FE FE FE FE is the error code, indicating that the sensor is in the blind area and no valid data can be read.


    7.3 Query configuration information instruction: Function Code 0x03

    7.3.1 Broadcast query slave address

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0xFF(broadcast)0x030x20 010x00 010xCB D4

    Reply data:

    Device AddressFunction CodeLength of DataDataCRC
    0x7F0x030x020x00 7F0xD1 AE

    Data definition: The data type is int16 data, and the data length is 2 Bytes.

    Examples:

    Request: FF 03 20 01 00 01 CB D4

    Reply: 7F 03 02 00 7F D1 AE

    The data part 0x 00 7F is converted to integer data, which is 127 or 0x7F.


    7.3.2 Query the baud rate of the communication interface

    Note: Baud rate only supports: 4800,9600,19200,38400,115200

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RregistersCRC
    0x7F0x030x20 020x00 020x64 15

    Reply data:

    Device AddressFunction CodeLength of DataDataCRC
    0x7F0x030x040x00 00 25 800x7F 04

    Data definition: The data type is int32(big) data, and the data length is 4 bytes.

    Examples:

    Request: 7F 03 20 02 00 02 64 15

    Reply: 7F 03 04 00 00 25 80 7F 04

    The data part 0x 00 00 25 80 is converted to integer data, which is 9600.

    7.3.3 Query version information

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x030x20 040x00 020x84 14

    Reply data:

    Device AddressFunction CodeLength of DataDataCRC
    0x7F0x030x040x20 23 09 080x99 A8

    Data definition: The data type is int32 data, and the data length is 4 bytes. Version numbers were coded in BCD format.

    Examples:

    Request: 7F 03 20 04 00 02 84 14

    Reply: 7F 03 04 20 23 09 08 99 A8

    The data part is 0x 20230908, and the data is encoded in BCD format, namely the version number is 20230908.


    7.3.4 Query calibration parameters

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x030x20 520x00 010x24 05

    Reply data:

    Device AddressFunction CodeLength of DataDataCRC
    0x7F0x030x020x00 100x91 82

    Data definition: The data type is int16 data, the unit is millimeter (mm), and the data length is 2 Bytess.

    Examples:

    Request: 7F 03 20 52 00 01 24 05

    Reply: 7F 03 02 00 10 91 82

    The data part 0x 00 10 is converted to integer data, that is, 16 mm.


    7.3.5 Query automatic push cycle

    Note: When the automatic push period is >=300ms, the sensor will automatically push data. When the installation height is not set ( level cannot be calculated), push the air height data; When the mounting height is set, push the level data.

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x030x20 530x00 010x75 C5

    Reply data:

    Device AddressFunction CodeLength of DataDataCRC
    0x7F0x030x020x03 E80x90 F0

    Data definition: The data type is int16 data, the unit is milliseconds (ms), and the data length is 2 Bytes.

    Examples:

    Request: 7F 03 20 53 00 01 75 C5

    Reply: 7F 03 02 03 E8 90 F0

    Where the data part 0x 03 E8 is converted to integer data, that is, 1000 ms.


    7.3.6 Query blind area

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x030x20 440x00 020x85 C0

    Reply data:

    Device AddressFunction CodeLength of DataDataCRC
    0x7F0x030x040x6D B7 3E AB0x99 61

    Data definition: The default data type is float(little16) data, the default unit is meters (m), and the data length is 4 bytes.

    Examples:

    Request: 7F 03 20 44 00 02 85 C0

    Reply: 7F 03 04 6D B7 3E AB

    The data part 0x 6D B7 3E AB was converted to floating-point type data, that is, 0.334 m.


    7.3.7 Query range

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x030x20 460x00 020x24 00

    Reply data:

    Device AddressFunction CodeLength of DataDataCRC
    0x7F0x030x040x00 00 42 200x55 4C

    Data definition: The default data type is float(little16) data, the default unit is meters (m), and the data length is 4 bytes.

    Examples:

    Request: 7F 03 20 46 00 02 24 00

    Reply: 7F 03 04 00 00 42 20 55 4C

    The data part 0x 00 00 42 20 is converted to floating point data, that is, 40.0m.


    7.3.8 Check the depth at installation

    Note: The water depth at the time of installation is used to calculate the installation height. Installation height = water depth at installation + real time height at installation. When setting the water depth at the time of installation, the installation height is automatically calculated and saved to the configuration.

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x030x20 480x00 020x45 C3

    Reply data:

    Device AddressFunction CodeLength of DataDataCRC
    0x7F0x030x040x47 AE 40 B10xE0 D5

    Data definition: The default data type is float(little16) data, the default unit is meters (m), and the data length is 4 bytes.

    Examples:

    Request: 7F 03 20 48 00 02 45 C3

    Reply: 7F 03 04 47 AE 40 B1 E0 D5

    The data part 0x 47 AE 40 B1 was converted to floating point data, that is, 5.54 m.


    7.3.9 Check installation height

    Note: Set the mounting height, which is used to calculate the level. Real-time level = installation height - real time height. At the same time, installation height = water depth at installation + height at installation time. Therefore, when setting the installation height, the water depth during installation will be automatically calculated and saved to the configuration.

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x030x20 4A0x00 020xE4 03

    Reply data:

    Device AddressFunction CodeLength of DataDataCRC
    0x7F0x030x040x8A 64 41 2A0xBE 7C

    Data definition: The default data type is float(little16) data, the default unit is meters (m), and the data length is 4 bytes.

    Examples:

    Request: 7F 03 20 4A 00 02 E4 03

    Reply: 7F 03 04 8A 64 41 2A BE 7C

    The data part 0x 8A 64 41 2A is converted to floating point data, that is, 10.65m.

    7.4 Set instruction: Function Code 0x10

    7.4.1 Set the slave address

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersLength of DataDataCRC
    0x7F0x100x20 010x00 010x020x00 010x6E 21

    Reply data:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x100x20 010x00 010x51 D7

    Data definition: The data type is int16 data, and the data length is 2 Bytess.

    Examples:

    Request: 7F 10 20 01 00 01 02 00 01 6E 21

    The data part 0x 00 01 is converted to integer data, that is, 1 or 0x01.

    Reply: 7F 10 20 01 00 01 51 D7


    7.4.2 Set baud rate of communication interface

    Note: Baud rate only supports: 4800,9600,19200,38400,115200

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersLength of DataDataCRC
    0x7F0x100x20 020x00 020x040x00 01 C2 000x75 3E

    Reply data:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x100x20 020x00 020xE1 D6

    Data definition: The data type is int32 data, and the data length is 4 bytes.

    Examples:

    Request: 7F 10 20 02 00 02 04 00 01 C2 00 75 3E

    The data part 0x 00 01 C2 00 is converted to integer data, which is 115200.

    Reply: 7F 10 20 02 00 02 E1 D6


    7.4.3 Setting calibration parameters

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersLength of DataDataCRC
    0x7F0x100x20 520x00 010x020x00 010xA2 4E

    Reply data:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x100x20 520x00 010xA1 C6

    Data definition: The data type is int16 data, the unit is millimeter (mm), and the data length is 2 Bytes.

    Examples:

    Request: 7F 10 20 52 00 01 02 00 10 A2 4E

    The data part 0x 00 10 is converted to integer data, that is, 16 mm.

    Reply: 7F 10 20 52 00 01 A1 C6


    7.4.4 Set automatic push cycle

    Note: When the automatic push period is >=300ms, the sensor will automatically push data. When the installation height is not set ( level cannot be calculated), push the air height data; When the mounting height is set, push the level data.

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersLength of DataDataCRC
    0x7F0x100x20 530x00 010x020x03 E80xA2 ED

    Reply data:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x100x20 530x00 010xF0 06

    Data definition: The data type is int16 data, the unit is milliseconds (ms), and the data length is 2 Bytes.

    Examples:

    Request: 7F 10 20 53 00 01 02 03 E8 A2 ED

    Where the data part 0x 03 E8 is converted to integer data, that is, 1000 ms.

    Reply: 7F 10 20 53 00 01 F0 06


    7.4.5 Set the water depth at the time of installation

    Note: The water depth at the time of installation is used to calculate the installation height. Installation height = water depth at installation + real time height at installation. When setting the water depth at the time of installation, the installation height is automatically calculated and saved to the configuration.

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersLength of DataDataCRC
    0x7F0x100x20 480x00 020x040x47 AE 40 B10x75 30

    Reply data:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x100x20 480x00 020xC0 00

    Data definition: The default data type is float(little16) data, the default unit is meters (m), and the data length is 4 bytes.

    Examples:

    Request: 7F 10 20 48 00 02 04 47 AE 40 B1 75 30

    The data part 0x 47 AE 40 B1 was converted to floating point data, that is, 5.54 m.

    Reply: 7F 10 20 48 00 02 C0 00

    7.4.6 Set the installation height

    Note: The installation height is the distance from the sensor to the 0 object level. If the current water depth is 2 meters and the air height is 4 meters, the installation height is 6 meters. Set the mounting height, which is used to calculate the level. Real-time level = installation height - real time height. At the same time, installation height = water depth at installation + height at installation time. Therefore, when setting the installation height, the water depth during installation will be automatically calculated and saved to the configuration.

    Request command:

    Device AddressFunction CodeRegister AddressNumber of RegistersLength of DataDataCRC
    0x7F0x100x20 4A0x00 020x040x8A 64 41 2A0xAA 40

    Reply data:

    Device AddressFunction CodeRegister AddressNumber of RegistersCRC
    0x7F0x100x20 4A0x00 020x61 C0

    Data definition: The default data type is float(little16) data, the default unit is meters (m), and the data length is 4 bytes.

    Note: Setting the mounting height to 0 will clear the mounting height/water depth configuration at installation.

    Examples:

    Request: 7F 10 20 4A 00 02 04 8A 64 41 2A AA 40

    The data part 0x 8A 64 41 2A is converted to floating point data, that is, 10.65m.

    Reply: 7F 10 20 4A 00 02 61 C0


    7.5 Text protocol

    7.5.1 Communication protocol hardware interface parameters

    The water level meter adopts serial communication, and the default parameters are as follows:

    Communication parameters


    Serial port levelBaud rateParity checkLength of DataStop position
    Serial portTTL9600-81

    The timeout time was 50ms for each frame interval.


    7.5.2 Description of communication protocol commands

    Note: "n" represents a newline, corresponding to the hexadecimal number 0x0A. After the setup command configuration is successful, the configuration will be saved in Flash, and no reconfiguration is needed to restart the power outage.

    The command error response is as follows:

    Command error responseDescription
    This AT cmd is errornInstruction error
    This AT cmd is no existnInstruction does not exist
    This AT cmd is exist,but not allow to operatenInstructions exist but are not allowed to operate
    This AT cmd is exist,but value is errornIncoming parameter error

    1.Read the real spatio-temporal height

    Unit: Meter (m)

    InstructionDescription
    SendAT+REALAIRHEIGHTnRead the real spacetime height
    ReplyREALAIRHEIGHT=2.212mnThe current real spacetime height is 2.212 meters
    ReplyREALAIRHEIGHT=OutRangenOut of range
    ReplyREALAIRHEIGHT=InBlindZonenThe sensor is in the blind area
    ReplyREALAIRHEIGHT=LackEnergynThe echo energy is insufficient

    2.Read the real-time level

    Unit: Meter (m)

    The calculation method of the level is: installation height - air height

    InstructionDescription
    SendAT+REALWATERDEPTHnRead real-time level
    ReplyREALWATERDEPTH=7.789mThe current real-time level is 7.789 meters
    ReplyREALWATERDEPTH=OutRangenOut of range
    ReplyREALWATERDEPTH=InBlindZonenThe sensor is in the blind area
    ReplyREALWATERDEPTH=LackEnergynThe echo energy is insufficient
    ReplyREALWATERDEPTH=No Set InstallHeightnThe installation height is not set

    3.Water depth at installation

    Unit: Meter (m)

    Note: The water depth at the time of installation is used to calculate the installation height. Installation height = water depth at installation + real time height at installation. When setting the water depth at the time of installation, the installation height is automatically calculated and saved to the configuration.

    Read the water depth at installation:

    InstructionDescription
    SendAT+INSTALLWATERDEPTHnRead the water depth at installation
    ReplyINSTALLWATERDEPTH=4.60mnWater depth at installation is 4.60 meters

    Set the water depth at the time of installation:

    InstructionDescription
    SendAT+INSTALLWATERDEPTH=4.6nWater depth is set to 4.6 m during installation
    Reply

    AT+INSTALLWATERDEPTH=4.6n

    OKn

    Operation successful

    4.Height of installation

    Unit: Meter (m)

    Note: Set the mounting height, which is used to calculate the level. Real-time level = installation height - real time height. At the same time, installation height = water depth at installation + height at installation time. Therefore, when setting the installation height, the water depth during installation will be automatically calculated and saved to the configuration.


    Read mounting height:

    InstructionDescription
    SendAT+INSTALLHEIGHTnRead mounting height
    ReplyINSTALLHEIGHT=9.72mnWater depth at installation is 9.72 meters

    Set mounting height:

    InstructionDescription
    SendAT+INSTALLHEIGHT=9.72nSet the installation height to 9.72 m
    Reply

    AT+INSTALLHEIGHT=9.72n

    OKn

    Operation successful

    Note: Setting the mounting height to 0 will clear the configuration for mounting height and water depth at installation.


    5.Read the version number

    InstructionDescription
    SendAT+VERSIONnRead version number
    ReplyVERSION=20230908nThe version number is 20230908

    6.Read range

    Unit: Meter (m)

    InstructionDescription
    SendAT+RANGEnRead range
    ReplyRANGE=40.00mnThe range is 40 meters

    7.Read blind area

    Unit: Meter (m)

    InstructionDescription
    SendAT+BLINDZONEnRead blind area
    ReplyBLINDZONE=0.335mnThe blind zone is 0.335 meters

    8.Software reset (reboot)

    InstructionDescription
    SendAT+BOOTnSoftware reset
    Reply

    AT+BOOTn

    OKn

    Operation successful

    9.Factory data reset

    InstructionDescription
    SendAT+DEFAULTnFactory data reset
    Reply

    AT+DEFAULTn

    OKn

    Operation successful

    10.Frequency of acquisition

    Unit: milliseconds (ms)

    Note: The default acquisition frequency is 300ms, and the acquisition frequency can only be adjusted to 200ms at the earliest. (If the acquisition frequency jumps too fast, the speed of responding to the reply instructions will be slow, and the sending instructions may be incomplete, resulting in no response. In this case, the instruction can be sent again.)

    Read acquisition frequency:

    InstructionDescription
    SendAT+COLLECTFREQnRead acquisition frequency
    ReplyCOLLECTFREQ=200nThe acquisition frequency is 200 ms/cyclel

    Set collection frequency:

    InstructionDescription
    SendAT+COLLECTFREQ=500nSet the acquisition frequency to 500 ms/cycle
    Reply

    AT+COLLECTFREQ=500n

    OKn

    Operation successful

    11.Baud rate

    Read baud rate:

    InstructionDescription
    SendAT+BAUDRATEnRead baud rate
    ReplyBAUDRATE=9600nThe baud rate is 9600

    Set baud rate

    InstructionDescription
    SendAT+BAUDRATE=115200nSet the baud rate to 115200
    Reply

    AT+BAUDRATE=115200n

    OKn

    Operation successful

    12.Calibration parameters

    Unit: Millimeter (mm)

    Real spatio-temporal height = sampling value -calibration parameter. Therefore, when the real space-time height is larger than a fixed value, it can be calibrated by adjusting the quasi-parameters.

    Read calibration parameters:

    InstructionDescription
    SendAT+CALIBRATIONnRead calibration parameters
    ReplyCALIBRATION=16mmnThe calibration parameter is 16mm

    Setting calibration parameters:

    InstructionDescription
    SendAT+CALIBRATION=30nSet the calibration parameter to 30 mm
    Reply

    AT+CALIBRATION=30n

    OKn

    Operation successful

    13.Automatic push cycle

    Unit: milliseconds (ms)

    Note: When the automatic push period is >=300ms, the sensor will automatically report the real-time data. Among them, when the installation height (or water depth during installation) is set, the real-time data reported automatically is the real-time level; If the installation height is not set (or the water depth during installation), the real-time data reported automatically is the real time height.

    Read the automatic push cycle:

    InstructionDescription
    SendAT+AUTOOUTDATACYCLEnRead the automatic push cycle
    ReplyAUTOOUTDATACYCLE=100nAutomatic push cycle is 100 ms (less than 200 ms, no automatic push data)

    Set the automatic push cycle:

    InstructionDescription
    SendAT+AUTOOUTDATACYCLE=200nSet the automatic push period to 200 milliseconds
    Reply

    AT+AUTOOUTDATACYCLE=200n

    OKn

    Operation successful
    Quality Radar Level Gauge For Monitor Tank Level, Working Humidity 0~95% Supply Voltage 9~24V for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Radar Level Transmitter products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0