    Dual High Impedance Online PH Probe Differential Amplifier KPH601

    Ask Lasest Price
    Brand Name : kacise
    Model Number : KPH601
    Certification : CE
    Price : $0-$150
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 100
    Delivery Time : 3-10days
    • Product Details
    • Company Profile

    Dual High Impedance Online PH Probe Differential Amplifier KPH601

    KPH601 Online PH Sensor Signal Output: RS-485 (Modbus/RTU Protocol)

    1.Industrial pH measurement


    A retractable housing has great advantages when installed literally in a pipe-line. The pH electrode may be checked, cleaned, calibrated and

    replaced without interrupting the process. When installed in a pipe-line, no bypass valves are necessary. The possibility of withdrawing the

    electrode during the process helps to ensure a correct pH measurement. Retractable pH housings meet the requirements for an automatic

    pH measuring system. Probes without a retractable function enable the maintenance of an electrode only in combination with an interruption of

    the process, emptying of the vessel, etc. in pressurized systems.After having clarified the installation possibilities, the process determines the choice of suitable electrode and housing. Both components of the pH electrode assembly should suit the process requirements.

    Electrodes with a liquid electrolyte must be operated with an overpressure, preventing the measuring solution from entering into the

    reference electrolyte. The overpressure also ensures a constant cleaning of the junction. Housings for liquid electrolyte electrodes

    therefore posses a pressure chamber and a pressure indicator. Using this type of pH electrode assembly requires

    control of the overpressure and the periodic inspection of the level of the reference electrolyte. Because of their ability to be refilled, liquid

    filled electrodes have a long life expectancy if maintained correctly.Also, in the case of difficult measurements a special electrolyte may be used.


    Electrodes with gel or polymer electrolytes require very little maintenance. Checking the overpressure and the electrolyte level is not necessary. Polymer electrolyte electrodes are pressure resistant and do not need a classical junction due to their special construction; therefore, they are less sensitive to contamination. Electrodes with a gel electrolyte may be supplied with an overpressure. Since their life expectancy is generally good, a gel or polymer electrode is often the most economical alternative due to their low maintenance costs. In addition, the probe can be kept small and simple, since no pressure chamber is needed. The probe in the probe housing has to have the same corrosion resistance as the reactor. In addition to stainless steel, alloyed materials (e.g. Hastelloy) and plastics (e.g. PVDF) are used.

    2.Signal processing and environmental influences

    The combination electrode provides a potential which is specific for the pH value. This signal has a high resistance. In order to represent it as a pH value, a special transmitter is needed. The potential of the pH electrode is also influenced by the temperature. Therefore, the pH transmitter offers the possibility of manual or automatic temperature compensation.

    3.Technical Specifications

    ModelKPH601
    Measuring Range0~14pH
    Resolution0.01pH
    Accuracy±0.1pH
    Working Temperature0~65℃
    Working Pressure<0.2MPa
    Temperature CompensationAuto temperature compensation (NTC)
    Power Supply12~24VDC ±10%
    Signal OutputRS-485(Modbus/RTU)
    Wetted MaterialPOM
    Mounting MethodImmersion mounting, 3/4 NPT thread
    Cable Length5 meters, other lengths can be customized
    CalibrationTwo-point calibration
    Power Consumption<0.3W@12V
    Protection GradeIP68

    4.Dimensional Drawing

    Note:The sensor connector is M16-5 core waterproof joint male head.

    5.Installation

    Note: The sensor should not be installed upside down or horizontally when installed, at least at an angle of 15 degrees or more.

    Contact Us

    Website www.kacise.com

    Phone +86-17719566736

    Email sales@kacise.com

    Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China



    Quality Dual High Impedance Online PH Probe Differential Amplifier KPH601 for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Water Quality Sensor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0