| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | DUBHE |
| Model Number : | DEM140-400W |
| Certification : | ISO |
The DEM-MBR flat plate membrane element from dubhe is characterized by a simple flat plate structure, which, together with the improved membrane surface characteristics, enables the rising fluid generated by aeration to effectively scour the membrane surface, making it difficult for particulate matter to be deposited on the membrane surface, and ensuring stable filtration performance.
Large-scale wastewater projects
Organic wastewater treatment;
Old sewage plant process improvement;
Surface water purification treatment;
Reverse osmosis system influent pre-treatment;
Restaurant or landscape wastewater treatment and reuse;
Car wash plant ship sewage recycling and reuse;
Various types of beverage factories, distilleries, food factories,
livestock factories, slaughterhouses, dyeing and finishing plants,
leather factories, pulp mills;
Wastewater treatment for pharmaceutical factories and
high-concentration organic treatment plants;
Large municipal wastewater treatment and reuse, community living
water reuse, department stores, office building water reuse, sewage
water reuse.


Monolithic Membrane Element Dimensions:


DEM140-200W series membrane modules are large membrane modules for large wastewater projects.

1,Setup preparation
(1) Determine the handling plan for putting the membrane into the
bioreactor to be installed, such as the handling route.
(2) Prepare the equipment to unload the membrane from the truck
(forklift, crane, trailer, etc.).
(3) Construction in the reactor tank should be completed before
installation, and please check the cleanup work. Please be sure to
remove any large pieces of trash (concrete blocks, cutting chips,
bits and pieces of material) that may be left in the tank.
2. Disassembly of Membrane Element
When unloading the membrane element from a truck, use equipment
such as a forklift, crane, or trailer, and use the following
methods for lifting the packaging style and sample.
(1) When shipping, the membrane element part and the aeration part
are bundled separately.
(2) When lifting the TORAY flatbed ultrafiltration membrane
element, attach the hook completely to the lifting ring and lift
horizontally. Please be careful not to damage the flow guide tube
and aeration tube of the membrane element, and ensure safety during
operation.
DEM-MBR membrane wastewater treatment technology is a new wastewater treatment technology that organically combines membrane separation technology and biochemical treatment technology, using Toray membrane separation equipment to retain activated sludge and macromolecular organic matter in the biochemical reactor, eliminating the secondary sedimentation tank, the concentration of activated sludge is greatly increased, the hydraulic retention time (HRT) and the sludge retention time (SRT) can be controlled separately, and the difficult to degrade substances in the The difficult to degrade substances are continuously reacted and degraded in the reactor.
(1) Do not drink the permeate water.
(2) When discharging or recycling the treated water, analyze the
treated water according to the purpose of use and make sure that it
meets the requirements for use.
(3) Hydrogen fluoride (HF) gas occurs when the membrane element is
burned after use. When the membrane element is discarded, it must
be disposed of by a professionally qualified disposal company.
(4) Open the air vent valve before adding fresh water to the
reaction tank to exhaust the air inside the membrane element. Close
the air vent valve after feeding water.
(5) It is recommended that surface water not be used in place of
fresh water for operation, as surface water may cause membrane
clogging if it contains large amounts of iron, manganese, calcium,
and silica.
(6) Do not perform excessive clear water testing, as clear water
operation may result in membrane clogging.
(7) Keep the membrane moist after water operation. Drying of the
membrane may result in a decrease in water permeability.
(8) Do not filter without proper aeration, as this may result in
clogging of the membrane surface.
(9) Chemicals, drugs, oils, or other substances that adversely
affect activated sludge must not be added to the reaction tank.
(10) The ABS support plate will be chemically cracked when it comes
in contact with some organic solvents, such as alcohol, oil or
synthetic detergents. Therefore, contact of the ABS support plate
with these substances should be avoided.
(11) Even within the operating conditions of the membrane module,
try to avoid sudden changes in parameters such as temperature, pH,
and differential membrane pressure.
(12)Regularly inspect and replace parts that need to be renewed.
(13) When removing the membrane module for maintenance, it is
necessary to keep the membrane in a moist state at all times.
Drying of the membrane may result in a decrease in water
permeability.
(14) When stopping the filtration operation, stop aeration flushing
of the membrane. However, it is not necessary to stop aeration
during the normal intermittent operation phase of membrane
filtration.
|