Sign In | Join Free | My burrillandco.com
Home > Power Cables >

Overhead Bare Conductor Wire AAAC Conductor (Flint nominal area: 374.5mm2)

    Buy cheap Overhead Bare Conductor Wire AAAC Conductor (Flint nominal area: 374.5mm2) from wholesalers
     
    Buy cheap Overhead Bare Conductor Wire AAAC Conductor (Flint nominal area: 374.5mm2) from wholesalers
    • Buy cheap Overhead Bare Conductor Wire AAAC Conductor (Flint nominal area: 374.5mm2) from wholesalers
    • Buy cheap Overhead Bare Conductor Wire AAAC Conductor (Flint nominal area: 374.5mm2) from wholesalers

    Overhead Bare Conductor Wire AAAC Conductor (Flint nominal area: 374.5mm2)

    Ask Lasest Price
    Brand Name : Zhenglan Cable
    Model Number : Nominal Area:575mm2 Overhead Bare Conductor Wire
    Certification : 3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007
    Payment Terms : L/C, T/T,
    Delivery Time : 15 days
    Price : 0.1-90USD/m
    Supply Ability : 15-30ton/day
    • Product Details
    • Company Profile

    Overhead Bare Conductor Wire AAAC Conductor (Flint nominal area: 374.5mm2)

    Overhead Bare Conductor Wire(Nominal Area:18.4~1439mm2), AAAC Conductor according to IEC 61089


    APPLICATION: AAAC is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is also suitable for laying across basins, rivers and valleys where special geographical teatures exist.


    STANDARD

    Basic design to BS 3242 / BS EN 50182 / IEC 61089 / ASTM B 399/B 399M / DIN 48201 -6 standards.


    CONSTRUCTION

    AAAC cable bvconsists of aluminum alloy wires. The aluminum alloy wires are concentrically stranded.

    This section deals with heat-treatable magnesium silicon type aluminium alloys to the applicable International Standard, the electrical and mechanical properties of which all fall within the values suggested by relevant standard. Conductors to all other recognized specifications can also be supplied. The alloys referred to have higher strength but lower conductivity than pure aluminium. Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR; Having lower breaking loads than the later, their use becomes particularly favourable when ice and wind loadings are low.


    (*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.


    ELECTRICAL PROPERTIES

    density@20ºC2.70 kg/dm
    Temperature Coefficient@20°C0.00360 (°C)
    resistivity@20°C0.0326 Ohms mm2/m
    linear Expansivity

    23 x10-6 (°C)


    SERVICE CONDITIONS

    Ambient Temperature-5°C - 50°C
    Wind Pressure80 – 130kg/m
    Seismic Acceleration0.12 - 0.05g
    Isokeraunic level10 – 18
    relative Humidity5 – 100%

    Overhead Bare Conductor Wire(Nominal Area:18.4~1439mm2), AAAC Conductor according to IEC 61089 CONSTRUCTION PARAMETERS

    • IEC 60189

    Code NumberNo. of WiresA2 ConductorsMax. DC Resistance of Conductor at 20°C
    Calculated AreaDiameter of WiresDiameter of ConductorApprox. WeightRated Strength
    mm²-mm²mmmmkg/kmdaNΩ/km
    16718.41.835.4950.45.431.7896
    25728.82.296.8778.78.491.1453
    407462.898.67125.913.580.7158
    63772.53.6310.8198.321.390.4545
    100191152.7813.9316.333.950.2877
    125191443.115.5395.442.440.2302
    160191843.5117.55506.154.320.1798
    200192303.9319.65623.767.910.1439
    250192884.3921.95790.884.680.1151
    315373633.5324.71998.9106.950.0916
    400374603.9827.861268.4135.810.0721
    450375184.2229.541426.9152.790.0641
    500375754.4531.151585.5169.760.0577
    560616453.6733.031778.4190.140.0516
    630617253.8935.012000.7213.90.0458
    710618174.1337.172254.8241.070.0407
    800619214.3839.422540.6271.620.0361
    9009110363.8141.912861.1305.580.0321
    10009111514.0144.113179339.530.0289
    11209112894.2546.753560.5380.270 0258


    Code NameTotal AreaStrandingConductor Nominal
    diameter
    Nominal WeightRated StrengthMaximum DC resistance
    at 20 oC
    AWG or MCMmm2No / mmmmkg/kmkNΩ /km
    Akron30.5815.527 x 1.685.04434.922.1588
    Alton48.6924.717 x 2.126.36687.831.3557
    Ames77.4739.197 x 2.678.0110812.420.8547
    Azusa123.362.447 x 3.3710.1117118.880.5365
    Anaheim155.478.557 x 3.7811.3421623.750.4264
    Amherst195.799.307 x 4.2512.7527230.030.3373
    Alliance246.9125.107 x 4.7714.3134337.830.2678
    Butte312.8158.6019 x 3.2616.3043546.460.2112
    Canton394.5199.9019 x 3.6618.3054858.560.1676
    Cairo465.4236.4019 x 3.9819.9064969.250.1417
    Darien559.5283.5719 x 4.3621.8077883.100.1181
    Elgin652.6331.0019 x 4.7123.5590896.980.1012
    Flint740.8374.5037 x 3.5925.131028107.360.0894
    Greeley927.2469.6037 x 4.0228.141289134.620.0713

    Why you choose us?

    • OEM/ODM services provided;
    • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
    • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
    • Registered capital of $30 million and factory covers an area of 60,000㎡;
    • Advanced test equipment and procedures, 100% inspection before factory;
    • Enough stocks and the higest efficient shipping time guarranteed;
    • Professional pre-sales and after-sales services provided.

    Quality Overhead Bare Conductor Wire AAAC Conductor (Flint nominal area: 374.5mm2) for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Zhenglan Cable Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Bare Aluminum Conductor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0