Sign In | Join Free | My burrillandco.com
Home > Inverters & Converters >

5 Kva 24v 48v110v 220v Off Grid Inverter With Ac Charger For Home Solar System

    Buy cheap 5 Kva 24v 48v110v 220v Off Grid Inverter With Ac Charger For Home Solar System from wholesalers
     
    Buy cheap 5 Kva 24v 48v110v 220v Off Grid Inverter With Ac Charger For Home Solar System from wholesalers
    • Buy cheap 5 Kva 24v 48v110v 220v Off Grid Inverter With Ac Charger For Home Solar System from wholesalers
    • Buy cheap 5 Kva 24v 48v110v 220v Off Grid Inverter With Ac Charger For Home Solar System from wholesalers
    • Buy cheap 5 Kva 24v 48v110v 220v Off Grid Inverter With Ac Charger For Home Solar System from wholesalers
    • Buy cheap 5 Kva 24v 48v110v 220v Off Grid Inverter With Ac Charger For Home Solar System from wholesalers
    • Buy cheap 5 Kva 24v 48v110v 220v Off Grid Inverter With Ac Charger For Home Solar System from wholesalers
    • Buy cheap 5 Kva 24v 48v110v 220v Off Grid Inverter With Ac Charger For Home Solar System from wholesalers

    5 Kva 24v 48v110v 220v Off Grid Inverter With Ac Charger For Home Solar System

    Ask Lasest Price
    Brand Name : TTNergy
    Model Number : TTN-DP
    Supply Ability : 50000 Piece/Pieces per Month
    Price : $118.00/pieces 5-20 pieces
    • Product Details
    • Company Profile

    5 Kva 24v 48v110v 220v Off Grid Inverter With Ac Charger For Home Solar System

    Products Description

    TTN Solar Inverter
    An on-grid inverter’s main job is to convert DC power generated from the PV array into usable AC power. Hybrid inverters go a step further and work with batteries to store excess power as well. In the developing world, hybrid inverters are more of a necessity to compensate for weak or intermittent grids or a lack of grid electricity all together.
    The Grid-interactive inverter consists of several hardware elements. The Grid-interactive inverter controls and monitors the connection of the electricity from the power plants. In addition, it also controls the disconnection of excess power from the plants. It ensures the dispatch of power at the peak time based on demand.

    TTN-DP/DP-T
    Higher yields / Safe & Reliable / Smart / User-friendly
    Low frequency toroidal transformer, small interference, working effciency up to 90%
    international standard copper wire diameter, provide strong load capacity
    Advanced circuit mother-board, fine workmanship full solder joints stable
    ●Low frequency toroidal transformer increase efficiency, Pure sine wave output
    ●Integrated LCD display; One-button start with an external display screen(optional)
    ●Dedicated DCP chip design; stable and high-speed operation
    ● LCD display easy to monitor the operation condition in real time
    ● AC charge current 0-30A adjustable; battery capacity configuration more flexible
    ● Three types working modes adjustable :AC first, DC first, energy-saving mode
    ● AVR output, all-around automatic protection function
    ● Frequency adaptive function, adapt to different grid environments
    ● Built-in PWM or MPPT controller optional
    ● Added fault codes query function, facilitate user to monitor the operation state in real time
    ● Support diesel or gasoline generator, adapt any tough electricity situation
    ● RS232/RS485 communication port/APP optional
    Model: DP/DP-T
    10212/24/48
    15212/24/48
    20212/24/48
    30224/48
    40224/48
    50248
    60248
    70248
    Rated Power
    1000W
    1500W
    2000W
    3000W
    4000W
    5000W
    6000W
    7000W
    Peak Power(20ms)
    3000VA
    4500VA
    6000VA
    9000VA
    12000VA
    15000VA
    18000VA
    21000VA
    Start Motor
    1HP
    1.5HP
    2HP
    3HP
    3HP
    4HP
    4HP
    5HP
    Battery Voltage
    12/24/48VDC
    24/48VDC
    24/48VDC
    48VDC
    Size(L*W*Hmm)
    555*297*184
    615*315*209
    Packing Size(L*W*Hmm)
    620*345*255
    680*365*280
    N.W.(kg)
    12
    13
    15.5
    18
    23
    24.5
    26
    27.5
    G.W.(kg)(Carton Packing)
    14
    15
    17.5
    20
    25.5
    27
    28.5
    30
    Installation Method
    Wall-Mounted
    Parameter
    Input
    DC Input Voltage Range
    10.5-15VDC(Single battery voltage)
    AC Input Voltage Range
    85VAC~138VAC(110VAC)/ 95VAC~148VAC(120VAC / 170VAC~275VAC(220VAC / 180VAC~285VAC(230VAC)
    / 190VAC~295VAC(240VAC)
    AC Input Frequency Range
    45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
    Max AC charging current
    0~30A(Depending on the model)
    AC charging method
    Three-stage (constant current, constant voltage, floating charge)
    Output
    Efficiency(Battery Mode)
    ≥85%
    Output Voltage(Battery Mode)
    110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
    Output Frequency(Battery Mode)
    50/60Hz±1%
    Output Wave(Battery Mode)
    Pure Sine Wave
    Efficiency(AC Mode)
    >99%
    Output Voltage(AC Mode)
    110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
    Output Frequency(AC Mode)
    Follow input
    Output waveform distortion
    (Battery Mode)
    ≤3%(Linear load)
    No load loss(Battery Mode)
    ≤0.8% rated power
    No load loss(AC Mode)
    ≤2% rated power( charger does not work in AC mode)
    No load loss(Energy saving Mode)
    ≤10W
    Battery Type
    VRLA Battery
    Charge Voltage :14V; Float Voltage:13.8V( 12V system; 24V system x2 ; 48V system x4)
    Customize battery
    Charging and discharging parameters of different types of batteries can be customized according to user requirements
    (charging and discharging parameters of different types of batteries can be set through the operation panel)
    Protection
    Battery undervoltage alarm / Battery undervoltage protection / Battery overvoltage alarm / Battery overvoltage protection /
    Battery overvoltage recovery voltage / Overload power protection / Inverter output short circuit protection / Temperature
    protection
    Alarm
    A
    Normal working condition, buzzer has no alarm sound
    B
    Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
    C
    When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
    Inside Solar controller
    (Optional)
    Charging Mode
    PWM or MPPT
    Charging current
    10A~60A(PWM or MPPT)
    10A~60A(PWM ) / 10A~100A(MPPT)
    PV Input Voltage Range
    PWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system)
    MPPT: 15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system)
    Max PV Input Voltage(Voc)
    (At the lowest temperature)
    PWM: 50V(12V/24V system); 100V(48V system) / MPPT: 150V(12V/24V/48V system)
    PV Array Maximum Power
    12V system: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A)/1120W(80A)/1400W(100A); 24V system:
    280W(10A)/560W(20A)/840W(30A)/1120W(40A)/1400W(50A)/1680W(60A)/2240W(80A)/2800W(100A);
    48V system: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A)
    Standby loss
    ≤3W
    Maximum conversion efficiency
    >95%

    Note:

    How to correctly match the battery capacity of the system is determined according to the specific usage requirements of the load and application scenarios, otherwise it will easily lead to insufficient battery capacity or excessive waste of power generation.
    For details, please refer to the manual recommendation or consult online customer service.
    Product Details
    Wiring Diagram
    1. We offer 3 optional working modes (transfer time≤4ms):

    01 Grid priority mode: When the grid and battery are connected to the inverter, grid will supply power to the loads directly after voltage being stabilized and charge batteries via inverter. When the grid is cut off, the battery will automatically continue to supply power via inverter.

    02 Energy saving mode: If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the inverter will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.

    03 Battery priority mode: When the grid and battery are connected to the inverter, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.
    Product packaging
    Certifications
    Company Profile
    Quality 5 Kva 24v 48v110v 220v Off Grid Inverter With Ac Charger For Home Solar System for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: TTN New Energy Technology (Wenzhou) Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Off Grid Solar Inverter products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0