Sign In | Join Free | My burrillandco.com
Home > Fans & Cooling >

Liquid Cooling Container Antspace HK3 210 Units Of Antminer S19 Pro+ Hydro

    Buy cheap Liquid Cooling Container Antspace HK3 210 Units Of Antminer S19 Pro+ Hydro from wholesalers
     
    Buy cheap Liquid Cooling Container Antspace HK3 210 Units Of Antminer S19 Pro+ Hydro from wholesalers
    • Buy cheap Liquid Cooling Container Antspace HK3 210 Units Of Antminer S19 Pro+ Hydro from wholesalers
    • Buy cheap Liquid Cooling Container Antspace HK3 210 Units Of Antminer S19 Pro+ Hydro from wholesalers

    Liquid Cooling Container Antspace HK3 210 Units Of Antminer S19 Pro+ Hydro

    Ask Lasest Price
    Brand Name : ANTSPACE
    Model Number : ANTSPACE HK3
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 100
    Delivery Time : Shipping Date: July 1-31, 2022
    • Product Details
    • Company Profile

    Liquid Cooling Container Antspace HK3 210 Units Of Antminer S19 Pro+ Hydro

    Bitmain Antspace HK3 Liquid Cooling Container Available for sale power distribution cabinets

    Bitmain Antspace HK3 Liquid Cooling Container

    Built with efficiency and hotter climates in mind, the BITMAIN ANTSPACE HK3 (known as model designation Antbox H3 V2 internally) has a maximum capacity of 210 units of Antminer S19 Pro+ Hydro with total consumption of a little over 1MW. The minimum ASIC quantity to compliment the order will be 195 S19 Pro+ Hydro units per container. This represents an approximate cost of $3,400,000 USD, plus shipping. The AntSpace HK3 is sold as a two-piece stackable set– a cooling tower and mining container. Refer to the brochure in the downloads tab for technical details.

    Price for AntSpace does not include door-to-door ocean freight service. Freight costs will be quoted at time of loading as shipping costs vary weekly, and by location. ExWorks / FOB incoterms available. Escrow available. 1 year manufacturer warranty included. S19 Pro+ Hydro warranty void if used outside the AntSpace HK3 system.

    Two versions rated for NORTH AMERICA and MIDDLE EAST (GCC) power requirements are available at this time only. AntSpace HK3 may function in countries outside of these regions. March batch with delivery in April and May batch with deliveries until August are available. Please consult a live chat agent for more information.

    Specification Details For ANTSPACE HK3

    Product Overview
    VersionANTSPACE HK3
    Dimensions (L*W*H) (mm)6058*2438*2896
    Miner Capacity210 units -S19 Hyd. Series miner
    Container CertificationChina Classification Society Certification
    Safety CertificationNorth America/Standards:NFPA 79:2021,UL 508A:2018 R8.21,
    CSA C22.2 No. 14-18,ANSI/ISO 12100:2012
    EU/Standards:EN ISO 12100,EN 60204-1
    Operating Power(kW)1047~1050
    PUE(Power Usage Effectiveness)1.022(Excluding cooling tower)/1.036(Including cooling tower)
    Input Voltage and Frequency415V±5% 60Hz(North America)
    400V±5% 50Hz(EU,Middle East)

    Detailed Characteristics
    Shipping Weight(T)8
    Operating Weight (T)12
    Main Switch of Power Distribution Cabinets(A)1200(North America)
    1250(EU,Middle East)
    Rated Current(A)952
    Standard Power(kW)1049
    Maximum Power(kW)1050
    Rated Current per Miner(A)10
    Inlet CableThe inlet cables can withstand high-voltage of above 600V, with the following requirements per phase:
    L1 single core cable 600kcMil(300mm²)x4
    L2 single core cable 600kcMil(300mm²)x4
    L3 single core cable 600kcMil(300mm²)x4
    N Single-core cable 600kcMil(300mm²)x4
    PE single-core cable 500kcMil(240mm²)x2
    Connection Interface(Cooling Tower)DN125(GB/T 9119-2010 PN16 DN125)
    Connection Interface(Plate Heat Exchage Interface)DN100(GB/T 9119-2010 PN16 DN100)
    Flow Rate(m³/h)>85
    Quantity of ANTSPACE powered by one 2500kVA Transformer2

    Specification Details For Dry-Wet Towers

    One of the following two Dry-Wet Towers can be chosen based on the personalized demand.

    Product Overview
    TypeDry-Wet Tower Traditional Type (DWT-T)Dry-Wet Tower Container Type (DWT-C)
    Dimensions(L*W*H)(mm)5800*2240*42006058*2438*2896
    Heat Dissipation Capacity(kW)10001000
    Outlet Temperature @ 28℃ Wet Bulb Temperature35℃35℃
    Container CertificationNoneChina Classification Society Certification
    Safety CertificationNorth America/Standards: NFPA 79:2021, UL 508A:2018 R8.21,
    CSA C22.2 No. 14-18, ANSI/ISO 12100:2012
    EU Standards: EN ISO 12100, EN 60204-1
    North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21,
    CSA C22.2 No. 14-18, ANSI/ISO 12100:2012
    EU Standards: EN ISO 12100, EN 60204-1
    Operating Power(kW)14~2814~28
    Motor Rated Voltage and Frequency415V±5% 60Hz(North America)
    400V±5% 50Hz(EU,Middle East)
    415V±5% 60Hz(North America)
    400V±5% 50Hz(EU,Middle East)
    Detailed Characteristics
    Shipping Weight(T)56
    Operating Weight(T)910
    Connection Interface(Container)DN125(GB/T 9119-2010 PN16 DN125)DN125(GB/T 9119-2010 PN16 DN125)
    Water Resupply Pipe InterfaceDN40(Internal thread)DN40(Internal thread)
    Drain Pipe InterfaceDN65(Internal thread)DN65(Internal thread)
    Noise Level @25℃, 16m70dBA70dBA
    Water Consumption(m³/h)1~1.51~1.5

    | Environmental Requirementss



    Environmental Requirements
    1Cooling tower is required to be placed on flat ground, horizontal degree (±1 degree).
    2The ground surfaced is required to be hardened and stable, able to withstand at least 14-ton load.
    3A 10-ton crane is needed for unloading ANTSPACE and cooling tower.
    4Add-on items such as stairs, transformers, cables, bridge racks and cable distribution boxes are not included in the delivery of ANTSPACE. BITMAIN team can provide design suggestions if needed.
    5Client needs to confirm the opening directon of container and it needs to face air-intake. Door on left is current design by defult.
    6Keep at least 2 meters of air in-take space around the cooling tower.
    7Altitude: ≤3000m. If the altitude is higher than 1000-meter, transformer and switch should be derated, the total power of ANTSPACE must be decreased by 1% for each elevation increment of 100 meters.
    8Operating temperature: -25°C to 40°C. Operating humidity: 10%RH to 90%RH. When the initial coolant temperature is below 20 °C, the internal circulation should be turned on to heat up the coolant to above 20 °C before starting the mining machine.
    9When the ambient temperature is below 5 ℃, the cooling tower can be switched to cold-dry mode.
    10Choose pure water or suitable antifreeze as coolant based on local climate conditions.
    11The suitable ambient temperature for ANTSPACE does not represent the suitable ambient temperature for mining machine.

    Quality Liquid Cooling Container Antspace HK3 210 Units Of Antminer S19 Pro+ Hydro for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Meta Miner
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Bitmain Antspace products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0