| Model | TS8280 |
| Optical Geometry | D/8(diffused illumination, 8-degree viewing angle) |
| SCI (specular component included)/SCE (specular component excluded)
; Include UV / excluded UV light source |
| Comply to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM
E1164,DIN5033 Teil7 |
| Characteristic | Φ30mm apertures, to adapt to the measurement of large sample; |
| Rotary press type structure, more convenient for testing; |
| Accurate measurement, can be used for laboratory color accurate
analysis and transmission; |
| Suitable for precise color measurement and quality control in
textile and garment printing and dyeing, plastic electronics,
ceramics and other industries; It can be used for fluorescence
sample measurement. |
| Integrating Sphere Size | Φ152mm |
| Light Source | Combined full spectrum LED light source, UV light source |
| Spectrophotometric Mode | Flat Grating |
| Senso | Silicon photodiode array (double row 40 groups) |
| Wavelength Range | 400~700nm |
| Wavelength Interval | 10nm |
| Semiband Width | 10nm |
| Measured Reflectance Range | 0~200% |
| Measuring Aperture | Φ30mm/Φ25.4mm |
| Specular Component | SCI/SCE |
| Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99
Munsell(C/2) |
| Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
| Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter), |
| YI(ASTM D1925,ASTM 313), |
| Metamerism Index MI, |
| Staining Fastness, Color Fastness, Color Strength, Opacity |
| 8° Glossiness,555 tone classification |
| Observer Angle | 2°/10° |
| Illuminant | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
| Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference
Values/Graph, PASS/FAIL Result, Color Simulation, Color Offset |
| Measuring Time | About 1.5s (Measure SCI & SCE about 3.2s) |
| Repeatability | Chromaticity value: MAV/SCI, within ΔE*ab 0.05 ( When a white
calibration plate is measured 30 times at 5 second intervals after
white calibration) |
| Inter-instrument Error | MAV/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) |
| Measurement Mode | Single Measurement, Average Measurement(2-99times) |
| Locating Method | Camera Locating |
| Dimension | L*W*H=370X240X260mm |
| Weight | About 7.8kg |
| Battery | AC 24V, 3A Power adapter power supply |
| Illuminant Life Span | 5 years, more than 3 million times measurements |
| Display | 7-inch TFT color LCD, Capacitive Touch Screen |
| Data Port | USB, Bluetooth ®5.0, trigger switch interface |
| Data Storage | Standard 1000 Pcs, Sample 30000 Pcs |
| Language | Simplified Chinese, English, Traditional Chinese |
| Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
| Storage Environment | -20~50℃, 0~85%RH (no condensing) |
| Standard Accessory | Power Adapter, USB Cable, User Guide, PC Software(Download from
office website), White and Black Calibration Cavity,Aperture |
| Optional Accessory | Micro Printer, Foot Switch, Rotating Bracket |
| Notes | Technical parameters are only for reference, subject to the actual
sale of the product |