OEM Submerged Immersion Cooling System Dry Cooler for Data Centers

    Buy cheap OEM Submerged Immersion Cooling System Dry Cooler for Data Centers from wholesalers
     
    Buy cheap OEM Submerged Immersion Cooling System Dry Cooler for Data Centers from wholesalers
    • Buy cheap OEM Submerged Immersion Cooling System Dry Cooler for Data Centers from wholesalers
    • Buy cheap OEM Submerged Immersion Cooling System Dry Cooler for Data Centers from wholesalers
    • Buy cheap OEM Submerged Immersion Cooling System Dry Cooler for Data Centers from wholesalers
    • Buy cheap OEM Submerged Immersion Cooling System Dry Cooler for Data Centers from wholesalers
    • Buy cheap OEM Submerged Immersion Cooling System Dry Cooler for Data Centers from wholesalers
    • Buy cheap OEM Submerged Immersion Cooling System Dry Cooler for Data Centers from wholesalers

    OEM Submerged Immersion Cooling System Dry Cooler for Data Centers

    Ask Lasest Price
    Brand Name : Shenglin
    Model Number : SHSL-D2 Series
    Certification : CE and RoHs
    Price : 20000~50001 USD per unit
    Payment Terms : T/T, Western Union
    Supply Ability : 100 units/ month
    Delivery Time : 35~40days
    • Product Details
    • Company Profile

    OEM Submerged Immersion Cooling System Dry Cooler for Data Centers

    Submeraged Coooling Two-Phase Immersion System For Data Centers​


    Advantages and disadvantages of dry cooler immersion cooling system


    Pros:

    - High build quality by necessity

    - Up to 98% reduction in cooling power

    - Long life fluid (20 years)

    - High cooling capacity (4kw per liter)

    - Equipment is dry and clean when removed

    - Fairly simple plumbing

    - Excellent scaling

    Cons:


    - Not ideal at small scales

    - Control costs are the same for 250kW and 10kW

    - Controls are complex and expensive

    - Cannot use HDDs

    - Tanks must be stainless

    - Fluids leak easily so quality control must be tightly adhered to


    The submeraged cooling system diagram by dry cooler:


    Shenglin and Shenglin partner can offer one-stop solution:


    For bitcoin mining farm, if use immersion cooling system, Shenglin dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.


    How to design a dry cooler?


    Tell Shenglin the datas as following:
    A. Required electrolyte inlet temperature?
    B. Required electrolyte​ outlet temperature?
    C. Electrolyte​ flow?
    D. Ambient temperature?
    E. Supply power(voltage-Hz-phase)
    G. Any other requirements ?


    Technical parameter of dry cooler
    Dry cooler FLAT SERIES SINGLE ROW FANS

    H*FS*91
    H*FS*125
    H*FS*180
    Van Dim
    mm
    *H*FS191 H*FS1125 H*FS1180H*FS291 H*FS2125 H*FS2180H*FS391 H*FS3125 H*FS3180H*FS491 H*FS4125 H*FS4180H*FS591 H*FS5125 H*FS5180H*FS691 H*FS6125 H*FS6180H*FS791 H*FS712 H*FS7180H*FS891 H*FS8125 H*FS8180
    Rated Capacities (kW) Heat Exchange Surface (㎡)
    Fluid
    Coolers
    910D61kW-648kW 120㎡-2307㎡ (Water/Ta25℃/Tin40℃/Tout35℃)
    1250138kW-1528kW 302㎡-4542㎡ (Water/Ta25℃/Tin40℃/Tout35℃)
    1800198kW-1920kW 363㎡-5084㎡ (Water/Ta25℃/Tin40℃/Tout35℃)
    Freon
    Condensers
    910F73kW-764kW 120㎡-2307㎡ (R404A/Ta35℃/Tk50℃)
    1250166kW-1549kW 302㎡-4842㎡ (R404A/Ta35℃/Tk50℃)
    1800230kW-1920kW 330㎡-5103㎡ (R404A/Ta35℃/Tk50℃)
    Ammonia
    Condensers
    910A72kW-779kW 141㎡-2721㎡ (NH3/Ta35℃/Tk50℃ )
    1250181kW-1554kW 351㎡-5625㎡ (NH3/Ta35℃/Tk50℃ )
    1800262kW-1986kW 421㎡-5907㎡ (NH3/Ta35℃/Tk50℃ )
    Gas
    Coolers
    910G49kW-862kW 96㎡-1824㎡ ( CO2/Tair32℃/Tin113℃/P94Bar/Tout34℃)
    Oil
    Coolers
    910O49kW-1041kW 120㎡-2307㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃)
    125075kW-2021kW 302㎡-4842㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃)
    180092kW-2505kW 330㎡-5103㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃)
    Fan
    Model
    910ECW3G910KU2503 (2.55kW) or FN091-ZIQ.GL.V5P1 (3.2kW)
    910ACW6D910GB0101 (2.02kW) or FN091-SDS.6N.V7P2 (1.85kW)
    1250EC160M2-8P-5.5kW/720RPM/1250_5-5_LP_39°_PPG_9W2L
    1250AC160M2-8P-5.5kW/720RPM/1250_5-5_LP_39°_PPG_9W2L
    No of Fans12345678
    Overall
    Dimensions
    910Lenth-11980348049806480798094801098012480
    Lenth-222804080588076809480112801308014880
    Width1230
    Height1740 (Including 800Leg)
    1250Lenth260046006600860010600126001460016600
    Width2280
    Height1970 (Including 800Leg)
    1800Lenth30005400780010200126001500017400//
    Width2280
    Height2170 (Including 1000Leg)

    Quality OEM Submerged Immersion Cooling System Dry Cooler for Data Centers for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shanghai Shenglin M&E Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Submerged Cooling System products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0