Sign In | Join Free | My burrillandco.com
Home > Drying Equipments >

TC Digital Temperature Unit , Date Center Accessories , from China Manufacturer - Zion Communiation

    Buy cheap TC Digital Temperature Unit , Date Center Accessories , from China Manufacturer - Zion Communiation from wholesalers
     
    Buy cheap TC Digital Temperature Unit , Date Center Accessories , from China Manufacturer - Zion Communiation from wholesalers
    • Buy cheap TC Digital Temperature Unit , Date Center Accessories , from China Manufacturer - Zion Communiation from wholesalers

    TC Digital Temperature Unit , Date Center Accessories , from China Manufacturer - Zion Communiation

    Ask Lasest Price
    Brand Name : Zion communication OR OEM
    Model Number : Data Center Equipment
    Certification : ISO, CE, RoHS, UL
    Payment Terms : T/T, L/C
    Supply Ability : 30,000 PCS / Month
    Delivery Time : Normally 10 workingdays
    • Product Details
    • Company Profile

    TC Digital Temperature Unit , Date Center Accessories , from China Manufacturer - Zion Communiation

    More detail please visit:

    https://www.zion-communication.com/Copper-System-Equipment.html


    TC Digital Temperature Unit
    Technical Data

    · 19"installation

    · Simple structure, easy installation;

    · Easy cabling & operation;

    · Disturbing resistance,reliable running ;

    · 2-way output (IEC320 C13 and NEMA 5-15R).

    TC Digital Temperature Unit
    Main Part
    Model No.Input Connector Type
    ZC70180101UK type(BS1363)
    ZC70180102German type(DIN49441)
    ZC70180103US type(NEMA 5-15P)
    Technical Parameters

    · Power supply: 220VAC+ 10%/-15% , 50/60Hz.

    · Temperature measuring range: -50℃ ~99℃.

    · Resoluton: 1℃.

    · Refrigeration output contact capacity: 10A/277VAC.

    · Senssor error delay time: 1min. .

    · Safe level: 1P65.

    · Operation humidity: 20~85%(no condensate).

    · Power consumption: ≤3W.

    · Temperature controling range: -40℃ ~50℃.

    · Accuracy: -50℃ ~70℃, ±1℃, ±1 ℃ at others can drive single phase compressor≤1/2HP.

    · Sensor: NTC.

    · Operation temperature: -30℃~75℃.

    Detalis:

    Key operation

    · Check parameter set value:

    Press ▲ and then loosen to display the set upper limit; Press and then loosen▼to display the.


    Modify parameter set value

    · Press set for more than 3s to cnter into parameter modifying status the last,display the last adjusted

    menu after electrified with parameter modifying indicator light on.

    · Press ▲ or▼to go forward or backward the menu item; press set to display the current.


    Parameter set value

    · Press set and ■ or ■ simultaneously can adjust the current parameter set value;press set and ■

    simultaneously more than 1s will increase current parameter set value quickly; press set and ■

    simultaneously more than 1s will decrease current parameter set value puickly;

    · Press rst or no key operation in 30s will save the modified parameter and retutn to normal

    temperature display status.


    Restore the parameter setting

    · When electrify the controller,first check the

    parameter setting,if parameter setting is

    wrong, LED display E1 with buzzer sound,at

    this time press Set will restore default

    parameter setting.

    · Advise to reset the parameter.


    Front panel


    2


    Key-press function
    Key-pressNormal modeParmeter modification mode
    SETCheck compressor protection timeDisplay current menu set value
    SET...3 secondsEnter into parameter modification
    RstCheck temperature exceeding valueQuit from parameter modification
    Temperature upper limits checkingMenu items go backwards
    Temperature lower limits checkingMenu items go forwards
    SET+Parameter values increase by degrees
    SET+Parameter values decrease by degrees

    Control output


    · Compressor: When the storage temp.Is higher than set temp.Upper limit,compressor starts,

    lower than set temp. Lower limit,compressor stops, When sensor errir, compressor works

    proportionably as on -15 minutes off -30 minutes. After electrified or compressor stops .

    Compressor restart-up is allowed after running out of compressor protection time.


    · Alarm: While temp.exceeding valus is not 0.LED blinkingly displays current temperature

    when storage temperature is higher than set temperature upper limip +exceeding temp

    value or lower than set lower limit-exceeding temp. value. When rumming out of the

    exceeding temp.limit alarm delay after electrified. exceeding temp.limit alarm starts

    with buzzer sound,and alarm cancel when temperature return to normal temperature

    LED blinkingly Display E1 with buzzer sound when memorizer error; display E2 with

    buzzer sound when sensor error, Display HH when temp. Higher than 99°C and lower

    than 120'C. Press any key to cancel alarm sound, but alarm status remains.

    Lndicator light descriptionWire diagram
    Indicator
    light
    StausFuncationTC Digital Temperature Unit-Wire diagram
    CoolAlways onCompressor cutput
    CoolFlashesCompressor cutput delay
    SetAlways onParmeter modification status
    Key-press function
    ItemFuntionFetting rangeUnitDefault
    F1Upper limitF2~+5°C-10
    F2Lower limit-40~F1°C-20
    F3Temperature calibration-5~5°C0
    F4Compressor protection time0~9Min3
    F5Exceeding temperatuer value0~50, set value as 0 to cancel alam°C15
    F6Exceeding temperature alarm delay timeF2~+5°C20

    Safety regulations


    · Danger: Strictly distinguish the sensor down-lead,power wire and output relay interface

    from one another,prohibit wrong connections or overloading the relay. All connections

    should be modified under electricity cut-off.


    · Warning: Prohibit to use the machine in water or under the environment of ower damp,

    high temperature,string electromagnetism interference ir string corrosion.


    · Caution: The power supply should conform to one labeled on the machine,and ensure

    the stability of the power voltage. Sensor down-lead and power should be kept for a

    proper distance to avoid possible interferences.


    Error Code
    CodeReasonStatus
    E1Memorizer errorAlarm,machine dose not work
    E2Sensor errorAlarm.Comressor starts/
    stop proportionably
    HHExceeding temp,
    display limit

    Quality TC Digital Temperature Unit , Date Center Accessories , from China Manufacturer - Zion Communiation for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: HANGZHOU ZION COMMUNICATION CO., LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Cabinet And Rack products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0