    Brand Name : CHX
    Model Number : CHX-DM023
    Certification : CE, RoHS
    Price : Negotiation
    Payment Terms : T/T, Western Union,Paypal,L/C
    Supply Ability : 50000pcs/month
    Delivery Time : 5-35days
    • Product Details
    • Company Profile

    USA Electrical Socket Circuit Receptacle Outlet Tester


    USA Electrical Socket Circuit Receptacle Outlet Tester


    Preparation


    1.1.1 When using the instrument, the user must comply with the standard safety rules:
    - Universal anti-shock protection
    - Prevent misuse of instruments
    1.1.2 After receiving the instrument, check if it is damaged during transport.
    1.1.3 in the rough conditions of preservation, shipment, check and confirm whether the instrument is damaged.
    1.1.4 The pen must be in good condition. Before use, check whether the insulation of the test leads is damaged and the wires of the wires are exposed.
    1.1.5 Use the table provided with the table to ensure safety, if necessary, must use the same or the same level of the pen to replace.

    Technical indicators

    Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
    3.2.1 True rms zero input
    3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
    3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
    3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.



    3.2.2 DC voltage

    RangeResolutionAccuracy
    6V0.001V±(0.5% of reading + 5 words)
    60V0.01V
    600V0.1V±(0.8% of reading + 5 words)

    - Input impedance: 10MΩ
    - Maximum input voltage: 600V DC or 600V AC (rms)
    Note:
    In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
    This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.


    3.2.3 AC voltage

    RangeResolutionAccuracy
    6V0.001V±(0.8% of reading + 3words)
    60V0.01V
    600V0.1V±(1.0% of reading + 10words)

    - Input impedance: 10MΩ

    - Maximum input voltage: 600V AC (RMS) or 600V DC

    - Frequency range: 40 ~ 1000Hz True RMS

    Note:
    In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
    This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.



    3.2.4 Alternating current

    RangeResolutionAccuracy
    600.0uA0.1uA±(1.5% of reading +10words)
    6000uA1uA
    60.00mA0.01mA
    600.0mA0.1mA
    6A0.001A±(2.5% of reading +10words)
    10A0.01A

    - Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
    10A range without insurance
    - Maximum input current: mA: 600mA DC or AC rms;
    10A: 10A DC or AC rms;
    When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
    - Frequency response: 40Hz ~ 1000Hz True RMS.

    3.2.5 DC

    RangeResolutionAccuracy
    600.0uA0.1uA±(1.0% of reading +5words)
    6000uA1uA
    60.00mA0.01mA
    600.0mA0.1mA
    6A0.001A±(2.0% of reading +10words)
    10A0.01A

    - Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
    10A range without insurance
    - Maximum input current: mA: 600mA DC or AC rms;
    10A: 10A DC or AC rms;
    When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.


    3.2.6 Frequency

    RangeResolutionAccuracy
    9.999Hz0.001Hz±(1.0% of reading +3words)
    99.99Hz0.01Hz
    999.9Hz0.1Hz
    9.999kHz0.001kHz
    99.99KHZ0.01kHZ
    999.9KHZ0.1KHZ
    9.999MHZ0.001MHZ

    - Overload protection: 250V DC or AC (rms)
    - Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)


    3.2.7 Duty cycle

    RangeResolutionAccuracy
    0.1 – 99.9%0.1%± 3.0%

    - Frequency response: 10 ~ 10MHz

    - Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)

    - Maximum input voltage: 250V AC (rms)

    Resistance

    RangeResolutionAccuracy
    600W0.1W±(0.8% of reading +3words)
    6kW0.001kW
    60kW0.01kW
    600kW0.1kW
    6MW0.001MW±(1.2% of reading +3words)
    60MW0.01MW

    - Open circuit voltage: approx. 1.0V
    - Overload protection: 250V DC or AC (rms)

    Transistor test


    RangeDescriptionTest Conditions
    hFEThe display reads the approximate value of hFE(0~1000)Base current of about 10uA; Vce about 2.8V

    Capacitance


    RangeResolutionAccuracy
    9.999nF0.001nF±(4.0% of reading +3words)
    99.99nF0.01nF
    999.9nF0.1nF
    9.999mF0.001mF
    99.99mF0.01mF
    999.9mF0.1mF
    9.999mF0.001mF±(5.0% of reading +3words)
    99.99mF0.01mFNot calibrated

    - Overload protection: 250V DC or AC (rms)


    Temperature test


    RangeAccuracyResolution
    -20℃-300℃±(1.0%+4d)1℃
    301℃-1000℃±(1.9%+5d)1℃
    -4℉-600℉±(1.2%+6d)1℉
    601℉-1832℉±(1.9%+6d)1℉

    - Overload protection: 250V DC or AC (rms)


    Quality USA Electrical Socket Circuit Receptacle Outlet Tester for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Digital Smart Multimeter products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0