Sign In | Join Free | My burrillandco.com
Home > Electrical Wires >

SS Mineral Insulated Wire Alloy Melting Low Melting Point

    Buy cheap SS Mineral Insulated Wire Alloy Melting Low Melting Point from wholesalers
     
    Buy cheap SS Mineral Insulated Wire Alloy Melting Low Melting Point from wholesalers
    • Buy cheap SS Mineral Insulated Wire Alloy Melting Low Melting Point from wholesalers
    • Buy cheap SS Mineral Insulated Wire Alloy Melting Low Melting Point from wholesalers

    SS Mineral Insulated Wire Alloy Melting Low Melting Point

    Ask Lasest Price
    Brand Name : MICH
    Model Number : MIHC
    Certification : ISO9001
    Price : USD0.5-USD5 per meter
    Payment Terms : L/C, T/T
    Supply Ability : 20 million meters per year
    Delivery Time : in one month
    • Product Details
    • Company Profile

    SS Mineral Insulated Wire Alloy Melting Low Melting Point

    Low Melting Point Alloy Melting Use MI Heating Cable for Metal Manufacturing Industry can meet the requirements of high temperature condition and high heating power (up to 269W/m).The maximum heating temperature can reach up to 600℃. Conductor resistance value ranges from 2.1 to 36100Ω/km supplied by MICH. Mineral insulated heating cable possesses excellent mechanical strength and corrosion resistance. The heating cable of series resistance can meet the requirements of different power.


    Application


    Nuclear industryconstruction -- asphalt heating
    Metal manufacturing industry- low melting point alloy meltingtank/vessel heating
    Shell heating for the extruderHeat tracing for high temperature industrial piping
    anticoagulation and viscosity reduction of process mediaAll kinds of industrial electric heaters

    Cable Structure

    Specification

    Heating cable instruction code


    MI SS-B 16K6560/60/2520/220/E1

    NO. 1 2 3 4 5 6 7


    No.Instruction
    1Sheath materialStainless steel
    2structure of cable componentsshown in table 1
    3cable codesshown in table 2, 3 and 4
    4length of heating cableIn meter
    5Heating cable powerIn Watt
    6heating cable voltageIn Volt
    7heating cable voltageSee table 5

    Cable Code

    Serial NO.Instruction
    1core number1 or 2
    2Voltage grade3=300V, 6=600V
    3conductor materialsK,N,C
    4cold resistance ×10006560=6.56Ω/m×1000

    1 6 K 6560

    No 1 2 3 4


    Table 1 Structure of Cable Element

    Table 2 Heating Cable Specification (600V Single Core)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    16C2.16.80.0021130184.2
    16C3.45.90.0034173138.7
    16C5.35.30.0053214111.9
    16C8.54.80.008526191.8
    16C134.30.01332573.7
    16C214.00.02137663.8
    16K405.80.04179164.7
    16K505.40.05206140.1
    16K605.20.06222126.7
    16K804.80.08261106.8
    16K1004.70.1200100.0
    16K1204.50.1220090.2
    16K1606.50.1620077.7
    16K2005.90.2200110.0
    16K2505.30.2521592.1
    16K4004.70.428074.0
    16K5004.50.530066.2
    16N6304.30.6318594.1
    16N10003.91.023091.3
    16N16003.61.627088.2
    16N25003.42.530069.8
    16N28003.42.830076.0
    16N33003.43.330068.9
    16N40003.24.035068.5
    16N52003.25.235068.2
    16N63003.26.335055.5
    16N100003.21035041.7

    Table 3 Heating Cable Specification (600V Double Cores)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    26K8.411.80.008443636.1
    26K13.49.80.013463433.7
    26K218.80.02178340.7
    26K348.00.03494275.2
    26K547.10.054119213.6
    26K856.40.085147171.2
    26K1306.00.13167148.6
    26K1807.90.1896273.3
    26K2607.40.26110235.4
    26K3606.80.36130196.6
    26K5006.40.5100172.1
    26K6505.90.65100145.6
    26K10005.71.0100134.1
    26K13006.21.3100161.5
    26K20005.82.0100139.8
    26K33005.43.3100119.5
    26N46005.84.6100139.0
    26N80005.48.0100119.2
    26N130005.013.0100101.3
    26N270004.827.010092.6
    26N400004.640.010084.9
    26N600004.460.010077.5
    26N720004.272.010070.6

    Table 4 Heating Cable Specification (300V Double Cores)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    23K2105.20.21222118.5
    23K3004.80.326199.4
    23K4004.80.426197.7
    23K4804.80.4826196.5
    23K6504.60.6528487.8
    23K10004.11.010069.3
    23K13003.81.310059.3
    23K20005.02.0100105.3
    23K24004.82.410096.2
    23K30004.63.010087.8
    23N46004.84.610096.8
    23N75004.67.510087.4
    23N112004.411.210079.2
    23N140004.214.010072.0
    23N180003.618.010052.9
    23N260003.626.010052.5
    23N400003.440.010046.6
    23N500004.050.010064.2
    23N600003.660.010052.0
    23N720003.472.010046.4

    Note:

    The resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

    If not specified, the sheath material is based on SS 321;

    For the use of 660V voltage occasions, please contact our company professionals.


    Table 5 terminal specifications


    Model: A, D, EModel: B
    Maximum Voltage (V)Maximum Current (A)Terminal SpecificationMaximum Current (A)Terminal Specification
    60015E220E1
    60020E225E2
    60030E340E2
    60050E370E2
    60070E3100E3

    Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

    Note 2: the length of cold end cable with standard configuration is 2 meters. If increase or decrease of length required, please contact our professional personnel.


    Corresponding reference table between the output power and sheath temperature


    Anticorrosive specification

    MaterialApplication
    SulfateNot Recommend
    Hydrochloric acidNot Recommend
    Hydrofluoric acidNot Recommend
    PhosphateNot Recommend
    CarbonateAccording to the real Data
    Organic acidApplicable at any condition
    Alkali metalAcceptable
    Sea waterNot Recommend
    ChlorideNot Recommend

    Explosion-proof instructions

    MISS series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to A, B, C (C1D2) level of explosion-proof electrical equipment.

    Quality SS Mineral Insulated Wire Alloy Melting Low Melting Point for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Pasia Industries Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Mineral Insulated Heating Cable products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0