    Brand Name : kacise
    Model Number : KEC310
    Certification : CE
    Price : $0-$2000
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 100
    Delivery Time : 3-10days
    • Product Details
    • Company Profile

    KEC310 Online Conductivity Sensor Easy to install submerged installation Ip68

    1.Application Environment

    Drinking water/surface water/various water supplies/industrial water treatment

    2.Feature

    • Signal Output: RS-485(Modbus/RTU protocol)
    • Convenient to connect to PLC, DCS, Industrial Control Computer, General Controller, paperless recording instrument or touch screen and other third-party equipment.
    • Easy to install: submerged installation.
    • Ip68, containment level.

    3.Technical Specifications

    Model numberKEC310
    Range and resolution0-5000μs/cm1
    Precision± 1.5% F.S.
    Operating temperature0 ~ 65 °C
    Working pressure< 0.6 mpa
    Power supply12 ~ 24 VDC ± 10%
    Signal outputRS-485(Modbus/RTU)
    Contact materialAbs
    Installation modeImmersion mounting
    Cable length5 meters, other length can be customized
    Temperature compensationAutomatic temperature compensation (PT1000)
    Calibration modeTwo-point calibration
    Power consumption< 0.05 W
    Protection levelIP68

    4.Dimensional Drawing

    5.Installation and Electrical Connection

    5.1 Installs

    Note: At least 2 cm away from the bottom and side walls of the container during installation and testing.

    5.2 Electrical connection

    The cable is a 4-core twisted pair shielded wire defined in line sequence:

    Red wire -- power cord (12V-24VDC)

    Black line (GND)

    Blue Line -- 485a

    White line -- 485b

    Before electrification, the wiring sequence should be carefully checked to avoid unnecessary losses caused by wiring errors.

    Wiring instructions: Consider the cable long-term immersion in water (including seawater) or exposed to air, all wiring is required to do waterproof treatment, customer cable should have a certain anti-corrosion ability.


    6.Maintenance

    6.1 Use and Maintenance

    The regular electrode needs to be cleaned and calibrated periodically, and the maintenance cycle is decided by the customer according to his own working condition. Conventional electrode cleaning method: with a soft brush to remove the attachment (care to avoid scratching the electrode surface) , and then clean with distilled water, after the calibration operation.

    Cleaning method of inductive electrode:

    Inductive electrode is basically maintenance-free; the shell of pollution or mild scaling does not affect its normal work.

    If cleaning, with a soft brush or sandpaper to remove the attachment, and then use distilled water cleaning, after the calibration operation.

    Because inductance type electrode often works in easy to scale up or dirty environment, cleaning can be appropriate to increase the force. A minor scratch on the electrode surface does not affect the normal operation of the electrode, but to avoid penetrating the electrode shell.

    6.2 Calibration

    a) Zero Calibration

    Rinse the sensor with distilled water and drain the liquid with filter paper. The sensor is connected to the power supply and placed vertically in the air for about 3 minutes. After the numerical value is stable, zero calibration is carried out. The calibration instructions are detailed in the appendix.

    b) slope calibration

    Place the electrode vertically in the standard solution (20% full range) and note that the slope of the electrode is calibrated at least 2 cm from the bottom and side walls of the container. The calibration instructions are detailed in the appendix.

    7.Quality and Service

    7.1 Quality Assurance

    Quality inspection departments have standardized inspection procedures, with advanced and perfect testing equipment and means, and in strict accordance with the rules of inspection, 72-hour aging of products to do experiments, stability experiments, do not let a unqualified product factory.

    The consignee will return the lot of the product with 2% nonconformity rate, and all the cost will be borne by the supplier. The standard of consideration refers to the product description provided by the supplier.

    Guarantee the quantity and speed of delivery.

    7.2 Spare Parts

    This product includes:

    1 sensor

    1 copy of instruction manual

    Certificate 1

    Calibration fluid (optional)

    7.3 After-sales Service Commitment

    Our company provides after-sale service for one year from the date of sale, but does not include damage caused by improper use. If repair or adjustment is needed, please return it at your own expense, the company will repair the damage of the instrument free of charge.


    Quality KEC310 Online Conductivity Sensor Easy to install submerged installation Ip68 for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Water Quality Sensor products from this supplier
    Inquiry Cart 0