Sign In | Join Free | My burrillandco.com
Home > Refrigeration & Heat Exchange Equipment >

KAN310 Online Ammonia Nitrogen Sensor RS485 Modbus Convenient to connect to PLC, DCS patented ammonium ion probe

    Buy cheap KAN310 Online Ammonia Nitrogen Sensor RS485 Modbus  Convenient to connect to PLC, DCS patented ammonium ion probe from wholesalers
     
    Buy cheap KAN310 Online Ammonia Nitrogen Sensor RS485 Modbus  Convenient to connect to PLC, DCS patented ammonium ion probe from wholesalers
    • Buy cheap KAN310 Online Ammonia Nitrogen Sensor RS485 Modbus  Convenient to connect to PLC, DCS patented ammonium ion probe from wholesalers
    • Buy cheap KAN310 Online Ammonia Nitrogen Sensor RS485 Modbus  Convenient to connect to PLC, DCS patented ammonium ion probe from wholesalers

    KAN310 Online Ammonia Nitrogen Sensor RS485 Modbus Convenient to connect to PLC, DCS patented ammonium ion probe

    Ask Lasest Price
    Brand Name : kacise
    Model Number : KAN310
    Certification : CE
    Price : $0-$500
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 100
    Delivery Time : 3-10days
    • Product Details
    • Company Profile

    KAN310 Online Ammonia Nitrogen Sensor RS485 Modbus Convenient to connect to PLC, DCS patented ammonium ion probe

    1.Application Environment

    KAN310 integrated on-line ammonia-nitrogen sensor is made of ammonium ion selective electrode based on PVC membrane, which is used to measure the content of ammonium ion in water with temperature compensation.

    2.Feature

    • Signal Output: RS-485 bus, Modbus/RTU protocol,
    • Convenient to connect to PLC, DCS, Industrial Control Computer, General Controller, paperless recording instrument or touch screen and other third-party equipment.
    • The patented ammonium ion probe, with an internal reference fluid at a pressure of at least 100 kpa (1 bar), oozes extremely slowly from the microporous salt bridge. Such a reference system is very stable and the electrode life is longer than ordinary industrial electrode life.
    • Easy to install: submerged installation.
    • Ip68, containment level.

    3.Technical Specifications

    Model NumberKAN310
    Range0 ~ 10.00 mg/L (0 ~ 100.00 mg/L)
    Resolution0.01 MGL
    Precision± 10% or ± 1MG/L
    Operating Temperature0 ~ 40 °C
    Working Pressure< 0.1 mpa
    The Ph Range Of The Medium4 ~ 10ph
    Temperature CompensationAutomatic temperature compensation (PT1000)
    Power Supply12 ~ 24 VDC ± 10%
    Signal OutputRS-485 bus, Modbus/RTU protocol
    Contact MaterialPVC and POM
    Installation ModeImmersion mounting
    Cable Length5 meters, other length can be customized
    Calibration ModeTwo-point calibration
    Power Consumption< 0.05 W
    Protection LevelIP68

    4.Dimensional Drawing

    5.Installation and Electrical Connection

    5.1 Installs

    Note: The sensor can not be installed upside down or horizontally, at least tilt more than 15 degrees angle installation.

    5.2 Electrical Connection

    The cable is a 4-core twisted pair shielded wire defined in line sequence:

    Red wire -- power cord (12V-24VDC)

    Black line (GND)

    Blue Line -- 485a

    White line -- 485b

    Before electrification, the wiring sequence should be carefully checked to avoid unnecessary losses caused by wiring errors.

    Wiring instructions: Consider the cable long-term immersion in water (including seawater) or exposed to air, all wiring are required to do waterproof treatment, customer cable should have a certain anti-corrosion ability.

    6.Maintenance

    6.1 Use and Maintenance

    Clean the electrode in distilled (or deionized) water and dry it, do not dry it. Place the electrodes on the electrode holder. Before use, the front end of the electrode is immersed in distilled (or deionized) water for 10 minutes, and then in a diluted solution of ammonium ions for 2 hours.

    The electrode should be kept dry before use. The sensor of the electrode should be put into the protective bottle. Before testing, the electrode should be immersed in the activation solution for 24 hours. If stored overnight or longer, the electrode head should be cleaned with deionized water, dried, and then placed in the original packaging.

    Check whether the terminal is dry, if there is any dirt, please wipe with absolute alcohol, blow dry after use. Long-term immersion in distilled water or protein solutions should be avoided and contact with silicone oils should be avoided. The longer the use of the electrode, its PVC membrane may become translucent or attached to sediment, at this time can be used distilled water (or deionized water) rinse. The electrode is used for a long time. If there is any measurement error, it must be corrected with the instrument.

    When the electrode can not be calibrated and measured in the above way, please replace the electrode.

    The main interfering ions are shown in the following table:

    The interference ion concentration with 10% error can be produced under different ammonium ion concentration

    Interferences (moles/liter)10-4m Ammonium10-3m ammonia10-2m Ammonium
    H +< 2< 1< 1
    Li +0.20.50.5
    Na +0.0050.080.8
    K +7 * 10-56 * 10-46 * 10-3
    CS +0.0030.050.5
    Mg3 +> 0.5> 1> 1
    Ca2 +> 0.2> 1> 1
    Sr2 +> 0.2> 1> 1
    Ba2 +> 0.1> 0.5> 0.5
    Zn2 +0.0010.010.1
    N2H5 +> 0.1> 0.1> 0.1
    Bu4n +1 * 10-51 * 10-41 * 10-3

    6.2 Calibration of Sensors

    Note: The sensor has been calibrated before the factory, if not out of measurement error should not be arbitrary calibration.

    Zero calibration

    Place the sensor in a vial containing a standard solution of zero point and wait 5 minutes for the value to stabilize to see if it is within the range of error, or if it is not, zero calibration is required. Reference Appendix to calibration instruction.

    Slope calibration

    Place the sensor in a vial containing the slope standard solution and wait 5 minutes until the values are stable to see if they are within the error range. If not, slope calibration is required. Reference Appendix to calibration instruction.

    7.Quality and Service

    7.1 Quality Assurance

    Quality inspection departments have standardized inspection procedures, with advanced and perfect testing equipment and means, and in strict accordance with the rules of inspection, 72-hour aging of products to do experiments, stability experiments, do not let a unqualified product factory.

    The consignee will return the lot of the product with 2% nonconformity rate, and all the cost will be borne by the supplier. The standard of consideration refers to the product description provided by the supplier.

    Guarantee the quantity and speed of delivery.

    7.2 Spare Parts

    This product includes:

    1 sensor

    1 copy of instruction manual

    Certificate 1

    1 mg/L and 10 mg/L calibration solution 100 ml each

    100 ml pre-activation fluid

    7.3 After-sales Service Commitment

    The company provides a one-year warranty from the date of sale, the electrodes are consumables warranty for half a year. But does not include the damage caused by improper use, if need repair or adjustment, please send back, but the freight is at your own expense, send back to make sure the packing is good to avoid damage in transit, our company will repair the damage free of charge.


    Quality KAN310 Online Ammonia Nitrogen Sensor RS485 Modbus  Convenient to connect to PLC, DCS patented ammonium ion probe for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Water Quality Sensor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0