Sign In | Join Free | My burrillandco.com
Home > Engineering & Construction Machinery >

Pt1000 Online Turbidity Sensor Scattering Light Method with accuracy ±5% or ±3NTU(0~1000NTU) ±3% or ±2NTU(0~100NTU) ±3%

    Buy cheap Pt1000 Online Turbidity Sensor Scattering Light Method with accuracy ±5% or ±3NTU(0~1000NTU) ±3% or ±2NTU(0~100NTU) ±3% from wholesalers
     
    Buy cheap Pt1000 Online Turbidity Sensor Scattering Light Method with accuracy ±5% or ±3NTU(0~1000NTU) ±3% or ±2NTU(0~100NTU) ±3% from wholesalers
    • Buy cheap Pt1000 Online Turbidity Sensor Scattering Light Method with accuracy ±5% or ±3NTU(0~1000NTU) ±3% or ±2NTU(0~100NTU) ±3% from wholesalers
    • Buy cheap Pt1000 Online Turbidity Sensor Scattering Light Method with accuracy ±5% or ±3NTU(0~1000NTU) ±3% or ±2NTU(0~100NTU) ±3% from wholesalers

    Pt1000 Online Turbidity Sensor Scattering Light Method with accuracy ±5% or ±3NTU(0~1000NTU) ±3% or ±2NTU(0~100NTU) ±3%

    Ask Lasest Price
    Brand Name : kacise
    Model Number : KNT601
    Certification : CE
    Price : $0-$600
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 100
    Delivery Time : 3-10days
    • Product Details
    • Company Profile

    Pt1000 Online Turbidity Sensor Scattering Light Method with accuracy ±5% or ±3NTU(0~1000NTU) ±3% or ±2NTU(0~100NTU) ±3%

    KNT601 Online Turbidity Sensor



    1.Working Principle



    KNT601 integrated online turbidity sensor is designed and manufactured using the principle of scattered light turbidity measurement. When a beam of light is incident on a water sample, the light is scattered by the turbidity substance in the water sample, and the intensity of the scattered light in the direction perpendicular to the incident light is measured and compared with the internal calibration value to calculate the turbidity in the water sample. Degree, linearized to output the final value.


    2.Feature


    • 90° angle scattered light principle, built-in temperature sensor
    • Support RS-485, Modbus/RTU protocol
    • Optical fiber structure, strong resistance to external light interference
    • Infrared LED light source with high stability
    • IP68 protection, water depth within 20 meters
    • Convenient, fast, stable and easy to maintain

    3.Technical Specifications


    ModelKNT601
    Measuring principleScattering light method
    Measuring range/Resolution0~1000NTU/0.1NTU /0.1℃
    0~100NTU /0.1NTU /0.1℃
    0~20NTU /0.01NTU/0.1℃
    Accuracy

    ±5% or ±3NTU(0~1000NTU)
    ±3% or ±2NTU(0~100NTU)
    ±3% or±1.5NTU(0~20NTU)
    ±0.5℃

    Calibration modeTwo-point calibration
    temperature compensationAutomatic temperature compensation(Pt1000)
    Output modeRS-485( Modbus /RTU)
    Working conditions0~50℃,<0.2MPa
    Storage temperature-5~65℃
    Installation modeImmersive installation, 3/4NPT thread
    Cable length5 meters, other lengths customizable
    power dissipation<0.3 W@12 V
    source12~24 VDC ±10%
    levels of protectionIP68

    4.Dimensional Drawing




    Note:The sensor connector is m16-5 core waterproof connector male.

    5.Installation and Electrical Connection


    5.1 Install

    Installation distance requirements: keep above 5 cm with side wall and above 10 cm with bottom.

    5.2 Electrical Connection

    • Red wire-power cord(12~24 V)
    • Black wire-ground wire(GND)
    • Blue Line-485 A
    • White Line-485 B
    • Bare wire-shield line

    After the wiring is completed, it should be carefully checked to avoid the wrong connection before the power is turned on.

    Cable specification: considering that the cable is immersed in water (including sea water) or exposed to air for a long time, the cable has a certain corrosion resistance. All interfaces of cable outer diameter Φ6mm, have been waterproof.

    6.Maintenance


    6.1 Maintenance Procedures and Methods

    6.1.1 Maintenance Schedule

    The cleanliness of the measuring window is very important for maintaining accurate readings.

    Maintenance taskRecommended maintenance frequency

    Calibrate sensors

    (If required by the competent authority)

    According to the maintenance schedule required by the competent department

    6.1.2 Maintenance Method

    • Sensor outer surface: clean the outer surface of the sensor with tap water, if there is still debris residue, wipe with wet soft cloth, for some stubborn dirt, you can add some household washing liquid to tap water to clean.
    • Check the cable of the sensor: the cable should not be tightened when it is working properly, otherwise it is easy to break the wire inside the cable and make the sensor unable to work properly.
    • Check the sensor measurement window if there is any dirt, cleaning brush is normal.

    6.1.3 Matters Need Attention
    The probe contains sensitive optical and electronic components. Make sure the probe is not subjected to severe mechanical impact. There are no components inside the probe that need to be maintained by the user.

    6.2 Calibration of Sensors

    a) Zero calibration: take proper amount of zero turbidity solution with large beaker, put the sensor vertically in the solution, the front end of the sensor is at least 10 cm from the bottom of the beaker, and the zero calibration will be carried out after the value is stabilized for 3 minutes. The instructions refer to the appendix.

    b) Slope calibration: the sensor probe is placed in the standard solution, the front end of the sensor is at least 10 cm from the bottom of the beaker, and the slope calibration is carried out after 3 ≤ 5 minutes of numerical stability. The instructions refer to the appendix.

    6.3 Frequently Asked Questions

    WrongProbable CauseSolution
    The operating interface cannot connect or does not display the measurement resultsThe measured value is too high, too low, or the numerical value remains unstable.Reconnect the controller and cable.
    Cable failurePlease contact us.
    The measured value is too high, too low, or the numerical value remains unstable.The sensor window is attached to the external object.Clean the window surface of the sensor.

    7.Quality and Service


    7.1 Quality Assurance

    • The quality inspection department has a standard inspection procedure, with advanced and complete detection equipment and means, and according to the procedure inspection, the product is subjected to 72-hour aging experiment and stability experiment, so that a non-conforming product is not allowed to leave the factory.
    • The consignee shall refund directly the product batches with a failure rate of 2%, and all expenses incurred shall be borne by the supplier. Consider the standard reference to the product description provided by the supplier.
    • Ensure the quantity of goods and the speed of shipment.

    7.2 Spare Parts

    This product includes:

    • One transmitter
    • One copy of explanation
    • One certificate of quality

    7.3 After-sales Service Commitment

    The Company has provided the local after-sales service within one year from the date of sales, but does not include the damage caused by improper use. If it is necessary to repair or adjust it, please return it, but the freight is required to be self-contained. When it is returned, it shall be confirmed that the package is good to avoid damage during transportation. The Company will repair the damage of the instrument free of charge.

    Contact Us


    Website www.kacise.com
    Phone +86-17719566736
    Email sales@kacise.com
    Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China


    Quality Pt1000 Online Turbidity Sensor Scattering Light Method with accuracy ±5% or ±3NTU(0~1000NTU) ±3% or ±2NTU(0~100NTU) ±3% for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Water Quality Sensor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0