    GE RAB4 8 D Ultrasound Probe Repair Crystal Replacement


    Repair 3D/4D GE RAB4-8-D Crystal/Crystal Replacement/Broken Probes


    Crystal damage -Weak, dead, or damaged crystals


    Very often the cause of crystal damage in ultrasound probes is the dropping of probe on the floor or hitting of probe with gel bottle or other object. Once a probe is dropped its piezoelectric crystals may stop sending or receiving signals, resulting in scans with weak or dead elements. This leads to black lines in an image, these lines are called dropouts. Weak elements cause the faint little lines that won’t obscure much. These are the first signs that the elements are getting progressively damaged and need to be replaced. Instead of faint lines if the lines are thick and pronounced, the elements are dead. If there are thick lines in the scanned image, important things can be missed out during diagnosis. You may be harming the patient due to misdiagnosis.


    Solution


    Repair/Replace the Crystal





    Other hot GE models we can repair:


    GEC1-5-D
    GEC1-5-RS
    GE4C
    GE4C-RS
    GE4C-A
    GE4C-D
    GE4C-SC
    GEE8C/E8C-RS
    GEE8CS
    GERIC5-9-D
    GE3CRF-D
    GEC1-6-D
    GERAB4-8-RS
    GERAB2-5-RS
    GE6S-RS
    GE12L-RS
    GE3SC-RS
    GEL6-12-RS
    GE11L
    GE11L-D
    GE12L-RS
    GE8C
    GE3S
    GE3S-RS

    Common ultrasonic Probe Damage(Convex, Linear, Sector, Endocavity probes)


    Common ultrasonic probe damageSolutions
    Lens damage, wear, holes, swelling, delaminationLens replacement
    Strain relief damage, separationStrain replacement
    Nosepiece and probe separation and cracks

    Cosmetic repairs

    Cable cutsCable patches, possible cable replacement
    Connector housing electrical damageMajor and minor electrical repairs, pin module replacement

    Probe Troubleshooting Summary
    1.Check whether multiple probes are the same phenomenon, sometimes it is necessary to plug again
    2.Lens and crystal failure are sometimes similar, both are shadowing on the image
    3.If there is a single probe problem, replace the socket to have a check.
    4.The high frequency probe (small parts probe) is sensitive. If only this probe doesn’t work, may be caused by machine failure.

    Easy Ultrasound Transducer Maintenance Tips & Damage Prevention


    Shipping

    If possible, use the box/case/foam from the manufacturer to protect the ultrasound probe during the shipping process.


    Storage

    Do not store in clamp control housing, which puts unneeded stress on the cord and strain relief. Instead, keep unused ultrasound probes in a cool, dry place — ideally in a case or box.


    Use

    Check the ultrasound transducer before each use to make sure all elements are properly functioning.


    Cleaning

    Before submerging the probe, make sure the strain relief and cord are undamaged. Don’t leave the ultrasound probe in contact with cleaning solutions for extended periods.



    Quality GE RAB4 8 D Ultrasound Probe Repair Crystal Replacement for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Guangzhou Rongtao Medical Tech LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Ultrasound Probe Repair products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0