The thermal conductivity tester developed using Transient Plane Heat Source Technology (TPS) for testing the thermal conductivity of a wide variety of materials. Transient planar heat source method is the latest in the study of thermal conductivity, which brings measurement technology to a whole new level. It can quickly and accurately measure the thermal conductivity when researching materials, which provides great convenience for enterprise quality monitoring, material production and laboratory research. The instrument is easy to operate, the method is simple and easy to understand, and will not cause damage to the sample to be tested.

Suitable for metal, ceramic, alloy, ore, polymer, composite, paper, fabric, foam (surface-level insulation, sheet), mineral wool, cement wall, glass reinforced composite board CRC, cement polystyrene board, sandwich Concrete, FRP panel composite panels, paper honeycomb panels, colloids, liquids, powders, granules and paste solids, etc., have a wide range of test objects.

Technical parameters:

Test range 0.005—300W/(m*K)
Measuring temperature range room temperature - 130 ° C
Probe diameter No. 1 probe 7.5mm; No. 2 probe 15mm
Accuracy ±3%
Repeatability error ≤3%
Measurement time 5~160 seconds
Power supply AC 220V
Machine power <500w
Sample temperature rise <15 ° C
Test sample power P No. 1 probe power 0 < P < 1w; No. 2 probe power 0 < P < 14w
Sample specifications Single sample (15*15*3.75mm) measured by the first probe; single sample (30*30*7.5mm) measured by the second probe.
Note: The No. 1 probe measures a thin material with a low thickness. The sample is superimposed if the surface of the sample is smooth and flat and sticky.

 

methods Transient plane heat source method laser method hot-wire technique guarded plate method
  not steady state method not steady state method not steady state method steady state method
measuring physical properties Thermal conductivity and thermal diffusivity are obtained directly. The thermal diffusivity and specific heat are obtained directly, and the thermal conductivity is calculated by the input sample density value. Thermal conductivity is obtained directly Thermal conductivity is obtained directly
application range solid, liquid, powder, paste, colloid, particle solid Solid, liquid solid
sample preparation No special requirements, simple sample preparation. Sample preparation is multifarious. Sample preparation is simple and has specific requirements. Larger sample size.
accuracy of measurement ±3%,better±0.5% better±10% better±5% better±3%
physical model Planar heat source contact measurement, as long as the finite surface contact is good. The heat source is contactless. The linear heat source must be in good contact with the linear model. Heat source contact type, need good surface contact.

Thermal conductivity range

[w/(m*k)]

0.005-300 10-500 0.005-10 0.005-5
measuring time 5-160S few minutes few minutes few hours
" }
Sign In | Join Free | My burrillandco.com
Home > Used General Industrial Equipment >

130C Transient Plane Source TPS Conductivity Analyzer

    Buy cheap 130C Transient Plane Source TPS Conductivity Analyzer from wholesalers
     
    Buy cheap 130C Transient Plane Source TPS Conductivity Analyzer from wholesalers
    • Buy cheap 130C Transient Plane Source TPS Conductivity Analyzer from wholesalers

    130C Transient Plane Source TPS Conductivity Analyzer

    Ask Lasest Price
    Brand Name : BAXIT
    Model Number : GLO-CT3
    Certification : CE,ISO
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 500 sets per month
    Delivery Time : 5-8 work days
    Price : Negotiable
    • Product Details
    • Company Profile

    130C Transient Plane Source TPS Conductivity Analyzer

    operation video


    The thermal conductivity tester developed using Transient Plane Heat Source Technology (TPS) for testing the thermal conductivity of a wide variety of materials. Transient planar heat source method is the latest in the study of thermal conductivity, which brings measurement technology to a whole new level. It can quickly and accurately measure the thermal conductivity when researching materials, which provides great convenience for enterprise quality monitoring, material production and laboratory research. The instrument is easy to operate, the method is simple and easy to understand, and will not cause damage to the sample to be tested.

    Suitable for metal, ceramic, alloy, ore, polymer, composite, paper, fabric, foam (surface-level insulation, sheet), mineral wool, cement wall, glass reinforced composite board CRC, cement polystyrene board, sandwich Concrete, FRP panel composite panels, paper honeycomb panels, colloids, liquids, powders, granules and paste solids, etc., have a wide range of test objects.

    Technical parameters:

    Test range0.005—300W/(m*K)
    Measuring temperature rangeroom temperature - 130 ° C
    Probe diameterNo. 1 probe 7.5mm; No. 2 probe 15mm
    Accuracy±3%
    Repeatability error≤3%
    Measurement time5~160 seconds
    Power supplyAC 220V
    Machine power<500w
    Sample temperature rise<15 ° C
    Test sample power PNo. 1 probe power 0 < P < 1w; No. 2 probe power 0 < P < 14w
    Sample specificationsSingle sample (15*15*3.75mm) measured by the first probe; single sample (30*30*7.5mm) measured by the second probe.
    Note: The No. 1 probe measures a thin material with a low thickness. The sample is superimposed if the surface of the sample is smooth and flat and sticky.

    methodsTransient plane heat source methodlaser methodhot-wire techniqueguarded plate method
    not steady state methodnot steady state methodnot steady state methodsteady state method
    measuring physical propertiesThermal conductivity and thermal diffusivity are obtained directly.The thermal diffusivity and specific heat are obtained directly, and the thermal conductivity is calculated by the input sample density value.Thermal conductivity is obtained directlyThermal conductivity is obtained directly
    application rangesolid, liquid, powder, paste, colloid, particlesolidSolid, liquidsolid
    sample preparationNo special requirements, simple sample preparation.Sample preparation is multifarious.Sample preparation is simple and has specific requirements.Larger sample size.
    accuracy of measurement±3%,better±0.5%better±10%better±5%better±3%
    physical modelPlanar heat source contact measurement, as long as the finite surface contact is good.The heat source is contactless.The linear heat source must be in good contact with the linear model.Heat source contact type, need good surface contact.

    Thermal conductivity range

    [w/(m*k)]

    0.005-30010-5000.005-100.005-5
    measuring time5-160Sfew minutesfew minutesfew hours
    Quality 130C Transient Plane Source TPS Conductivity Analyzer for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shanghai Glomro Industrial Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Thermal Conductivity Meter products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0