    30KW Resistive Load Bank For IEC 62040-3 UPS Test

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN2117R-30KW
    Certification : Calibration Certificate (Cost Additional)
    Price : Customized
    Payment Terms : L/C, , T/T, Western Union, MoneyGram
    Supply Ability : 20 sets per month
    Delivery Time : 30 Days
    • Product Details
    • Company Profile

    30KW Resistive Load Bank For IEC 62040-3 UPS Test


    30KW Resistive Load Bank for IEC 62040-3 UPS Test


    Equipment Overview:


    This electric energy load testing device is easy to operate, small in size and convenient to transport. Depending on the load capacity, multiple units can be used in parallel. The control method is divided into manual button control.

    Based on the requirements of IEC 62040-3 ED 2.0 2005 Annex C, figure C.1 and C.2, we have designed the load cabinet as following parts:

    A set of resistive load, the resistive load is 30KW, the rated voltage is AC220V/60HZ, at the same time meet the single-phase AC127V/60HZ power supply test, the capacity can also reach 30KW.


    Technical Parameters:


    System compositionLoad cabinet, resistive load, on-site data acquisition, manual load/unload control, electrical control part, heat sink and auxiliary control, etc.
    Total discharge powerResistive 30KW (designed according to three phase 220V/60HZ); at the same time meets 30KW single-phase 127V/60HZ (the current carrying capacity of the neutral line is the sum of the three-phase carrying capacity)
    Resistive load binning
    30KW total 6 gears
    Any adjustment by combinations within 1KW-30KW power range (minimum step 1KW): 1KW, 2KW, 2KW, 5KW, 10KW, 10KW.
    Test voltageThree-phase AC220V/single-phase AC127V
    Remark: Single and three-phase load test cannot be used at the same time
    Test frequency60HZ
    Resistance tubeEach resistance element: insulation resistance above 500MΩ, withstand voltage AC2000V for 1-minute, high temperature resistance
    Load characteristicsResistive load
    ContactorChina brand contactor
    BreakerChina brand breaker
    HeaterWuxi Zhuxing
    Power Factor1.0
    Load connectionY
    Loading accuracy±3%;
    Three-phase balanceThe unbalance degree is less than or equal to 3%;
    Way of workingContinuously working
    Power supplyAC220VAC/60HZ/three-phase four-wire system; (reserved wiring terminals)
    Cooling methodForced air cooling
    Way to controlManual button control
    Insulation classF
    Detection functionReal-time display of voltage, current, power, frequency, power factor, etc.
    Load protectionShort circuit, over current, high temperature, low air volume and fan failure protection
    Fault alarmThere is fan failure, load high temperature alarm
    Load cabinet dimensionsL700mm×W800mm×H1000mm (L×W×H), with pulley (height 150MM)
    Weight172KG
    Installation locationIndoor

    Power supply from test sample: If the power supply from the test sample is three phases, then all the GA, GB, GC and N terminals should be connected to test sample correspondingly (GA+GB+GC+N); if the power supply from the test sample is single phase, then one of the GA, GB, GC terminals plus N terminal should be connected to test sample correspondingly (such as GA+N terminals).


    Power supply from mains: the power supply from mains should be three phases AC220V/60Hz, the power supply is for the control components of this load bank. Operator should remove the lower three wires from the lower three terminals, and wrap up them well. Then operator uses the power supply cord we’ve offered to connect to the mains (L1+L2+L3+PE). The load bank must be grounded reliably before use.



    Quality 30KW Resistive Load Bank For IEC 62040-3 UPS Test for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Switch Life Tester products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0