Sign In | Join Free | My burrillandco.com
Home > Used Machinery & Equipment >

KPH500 PH/ORP sensor,Compact, flexible and easy to use,black PVC,gray meter host,water quality test.

    Buy cheap KPH500 PH/ORP sensor,Compact, flexible and easy to use,black PVC,gray meter host,water quality test. from wholesalers
     
    Buy cheap KPH500 PH/ORP sensor,Compact, flexible and easy to use,black PVC,gray meter host,water quality test. from wholesalers
    • Buy cheap KPH500 PH/ORP sensor,Compact, flexible and easy to use,black PVC,gray meter host,water quality test. from wholesalers
    • Buy cheap KPH500 PH/ORP sensor,Compact, flexible and easy to use,black PVC,gray meter host,water quality test. from wholesalers
    • Buy cheap KPH500 PH/ORP sensor,Compact, flexible and easy to use,black PVC,gray meter host,water quality test. from wholesalers

    KPH500 PH/ORP sensor,Compact, flexible and easy to use,black PVC,gray meter host,water quality test.

    Ask Lasest Price
    Brand Name : kacise
    Model Number : KBU601
    Certification : CE,FDA
    Price : $100-$2000
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 100
    Delivery Time : 10-15 days
    • Product Details
    • Company Profile

    KPH500 PH/ORP sensor,Compact, flexible and easy to use,black PVC,gray meter host,water quality test.

    Production Introduction
    The PH/ORP meter is a precision meter used to detect the pH/oxidation-reduction potential of liquids. It is designed with a microcomputer based on the principle of the primary battery and is simple to operate and easy to maintain. Not affected by color, turbidity, colloidal substances, oxidants and reducing agents, it is suitable for the determination of various media such as clean water, wastewater, industrial water, chemical reagents, etc., and is widely used in agriculture, environmental protection and industry.



    The sensor uses a composite electrode, which can eliminate the influence of the inconstant "K" value,
    A long-term, stable and accurate measurement of PH is realized. The internal structure of the sensor is shown on the right.





    Features


    1. LCD display, Chinese menu operation, stable performance and strong reliability
    2. High-performance operational amplifier, ORP positive and negative poles are symmetrical, small drift, high accuracy
    3. Data is not lost after power off
    4. Dual 4-20mA transmission output, relay high and low alarm control output, RS485 communication
    Output
    5. Simultaneous display of PH value, temperature value, output current value, high alarm value, low alarm value



    PH/ORP size structure chart

    Host size






    Sensor size



    PH/ORP technical parameters


    ClassPerformancePH parameterOPR parameter
    HostMeasuring range0-14PH-2000mv-2000mv
    Resolution0.01PH1mv
    Precision2% Calibration accuracy
    Operating TemperatureTransmitter 0-65℃
    MaterialPVC
    Protection LevelI65/IP67(customized version)
    Signal Output

    485 communication/4-20mA analog output/support HART protocol/NB.GPRS.LORA

    Communication (function option)

    Supply VoltageAC220V or DC24V (choose one of the two)
    Power Consumption<1W
    DisplayLCD Chinese display/TFT color LCD (customized version)
    Installation MethodWall mount
    SensorTemperature CompensationAutomatic temperature compensation
    Protection Levelip68
    Temperature0-60℃
    Sensor MaterialPVC
    Cable LengthDedicated PH cable, standard 5 meters (extendable)
    Operating Temperature0-60℃
    Storage Temperature-10-60℃
    Installation MethodBracket drop-in installation




    Ordering Information Selection Table
    KPH500PH/ORP analyzer
    Power supplyDC24V
    AC220V
    Cable length5m
    10m
    15m
    20m
    Temperature compensationSensor without temperature compensation
    Sensor with temperature compensation
    Signal outputOnly 4-20mA
    Only 485
    Also with 4-20mA , 485 signal output
    Special custom signal
    KPH500-P-DC24V-5m-Sensor without temperature compensation-Only 485PH host, with DC24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication.
    KPH500-R-AC220V-10m-Sensor with temperature compensation-Only 485

    Optional ORP host, with 220V adapter, line between host and sensor
    The cable length is 10 meters, the sensor with temperature compensation, and is equipped with only 485 communication signal output.


    Q&A
    What is pH?What is the principle of measurement?
    The pH value of the solution is the negative logarithm of the hydrogen ion activity in the solution, which is expressed as:
    PH = - lgαH +
    Because the value of hydrogen ion activity in aqueous solution is often very small, it is not convenient for application, so the concept of pH value is used
    As a solution acidity, neutral and alkaline indicators.Moreover, the pH value can indicate the strength of the acidity and alkalinity of the solution.
    In this way, it is very convenient to apply, and thus:
    Neutral solution: [H+]= [OH-] = 1X10^-7
    Moles per liter, pH is minus lg[H+] is equal to 7
    Acid solution: [H+] > [OH -], [H +] > 10^-7Mol /L, pH < 7, the lower the pH, the more acidic;
    Alkaline solution: [H+]<[OH-], [H +] < 10^-7Mol /L, pH >7, the higher the pH, the more basic it is.
    Activity is the effective concentration, that is, the portion of the ion that is free to participate in a given reaction - that is, to reach the surface of the electrode sensitive membrane to connect to it
    The part of the ion that's touching it.Because of the interaction between ions in a solution, the activity is usually less than the concentration, and this interaction will also be
    Blocking the movement of ions reduces the number of ions reaching the electrode membrane.

    the measurement of pH electrode is the characteristic of corresponding relation between the output potential of galvanic cell and the pH value of solution.
    This correspondence can be epresented by Nernst equation:
    E = Eo-2.3 RT/F*pH
    E = measure the potential
    Eo = standard potential
    R = the gas constant
    T = absolute temperature (K)
    F = Faraday constant
    RT/F = 2.3 slope
    The Nernst equation is a very important relation in electrochemistry.

    When measuring pH, Eo(standard potential) and 2.3RT/F(slope) are obtained by electrode calibration. Then the sample is measured to obtain E (measured potential) and the pH value of the sample is calculated by plugging into the equation.


    Why does the same sample give different readings on two pH meters?
    PH measurement errors are due to pH electrode, pH meter host, and standard buffer.Due to two pH meter calibration conditions are not the same (e.g., correction made at different times), resulting in slightly different measurements, so use the same buffer at the same time.
    Two pH meters were used for calibration, and then the pH value of the sample was determined simultaneously.


    What is a composite electrode?
    An electrode that combines a pH glass electrode with a reference electrode is called a pH composite electrode.The main advantage of the composite electrode is the combination of two
    For one, easy to use.The structure of pH composite electrode mainly consists of electrode bulb, support rod, reference electrode, reference solution, shell and liquid
    Junction, electrode cap, electrode wire, joint, etc.

    Contact us
    Website: www.kacise.com
    Phone: +86-17719566736
    Email: sales@kacise.com
    Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China

    Quality KPH500 PH/ORP sensor,Compact, flexible and easy to use,black PVC,gray meter host,water quality test. for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Water Quality Sensor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0